The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
Abstract
Previous studies have demonstrated that cerebral blood flow (CBF) can be assessed noninvasively by MRI using magnetic labeling of arterial water as a diffusible flow tracer. The purpose of this study was to assess the quality of CBF images obtained from patients with cerebrovascular disease using this method, and to begin to evaluate the potential clinical role for this technique. We recruited 14 patients who presented with stroke, TIA, or severe carotid stenosis and were likely to have altered CBF based on clinical assessment. In many of these patients, CBF imaging disclosed both focal and hemispheric hypoperfusion, either in vascular territories or in watershed regions. In 11 patients with significant proximal arterial stenosis, hemispheric CBF abnormalities localized to the side of most significant stenosis for the anterior circulation distribution. In several patients watershed hypoperfusion was even more pronounced. Our results suggest that good-quality MR CBF images can be obtained reliably from patients with cerebrovascular disease. CBF imaging can be combined with standard structural imaging within a single MRI examination, and provides clinically meaningful information. The capability of measuring CBF easily provides a potentially useful tool for clinical assessment and further investigation of stroke pathophysiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Lewy body variant of Alzheimer's disease: A clinical and pathologic entity
Hansen, L., Salmon, D., Galasko, D., Masliah, E., Katzman, R., DeTeresa, R., Thal, L., Pay, M. M., Hofstetter, R., Klauber, M., et al. (1990) · Neurology · doi:10.1212/wnl.40.1.1 · Cited by 1,068
Assessment [RETIRED]: Magnetoencephalography (MEG)
(1992) · Neurology · doi:10.1212/wnl.42.1.1 · Cited by 232
Cited by
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Chalela, J. A., Alsop, D. C., Gonzalez-Atavales, J. B., Maldjian, J. A., Kasner, S. E., & Detre, J. A. (2000) · Stroke · doi:10.1161/01.str.31.3.680 · Cited by 481
Self-citationComparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Self-citationAge-associated reductions in cerebral blood flow are independent from regional atrophy
Chen, J. J., Rosas, H. D., & Salat, D. H. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.12.032 · Cited by 360
Metadata
- Authors
- Detre, J. A., Alsop, D. C., Vives, L. R., Maccotta, L., Teener, J. W., & Raps, E. C.
- Venue
- Neurology
- Published
- 1998-03
- Volume
- 50
- Issue
- 3
- Pages
- 633-641
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2090035569
- Cited by
- 209
- References
- 2
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease. https://app.cochat.ai/papers/10.1212/wnl.50.3.633
- The paper
- Detre, J. A., Alsop, D. C., Vives, L. R., Maccotta, L., Teener, J. W., & Raps, E. C. (1998). Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease. Neurology. https://doi.org/10.1212/wnl.50.3.633
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.