Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 369

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla

Open access
Wang, Jiongjiong, Alsop, David C., Li, Lin, Listerud, John, Gonzalez‐At, Julio B., Schnall, Mitchell D., Detre, John A.·2002·Magnetic Resonance in Medicine

Abstract

High‐field arterial spin labeling (ASL) perfusion MRI is appealing because it provides not only increased signal‐to‐noise ratio (SNR), but also advantages in terms of labeling due to the increased relaxation time T1 of labeled blood. In the present study, we provide a theoretical framework for the dependence of the ASL signal on the static field strength, followed by experimental validation in which a multislice pulsed ASL (PASL) technique was carried out at 4T and compared with PASL and continuous ASL (CASL) techniques at 1.5T, both in the resting state and during motor activation. The resting‐state data showed an SNR ratio of 2.3:1.4:1 in the gray matter and a contrast‐to‐noise ratio (CNR) of 2.7:1.1:1 between the gray and white matter for the difference perfusion images acquired using 4T PASL, 1.5T CASL, and 1.5T PASL, respectively. However, the functional data acquired using 4T PASL did not show significantly improved sensitivity to motor cortex activation compared with the 1.5T functional data, with reduced fractional perfusion signal change and increased intersubject variability. Possible reasons for these experimental results, including susceptibility effects and physiological noise, are discussed. Magn Reson Med 48:242–254, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10211

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

See all 369

Metadata

Authors
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2002-07-31
Volume
48
Issue
2
Pages
242-254
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2154535553
Cited by
369
References
35
FWCI
13.56
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla. https://app.cochat.ai/papers/10.1002/mrm.10211
The paper
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002). Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10211

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.