Cortical sensorimotor reorganization after spinal cord injury: An electroencephalographic study
The DOI matches its Crossref record.
Abstract
The aim of this study was to determine if cortical motor representation and generators change after partial or complete paralysis after spinal cord injury (SCI). Previously reported evidence for a change in cortical motor function after SCI was derived from transcranial magnetic stimulation. These studies inferred a reorganization of the cortical motor system. We applied the new technique of high-resolution EEG to measure changes in cortical motor representation directly. We recorded and mapped the motor potential (MP) of the movement-related cortical potentials in 12 SCI patients and 11 control subjects. Results were analyzed using a distance metric to compare MP locations between patients and control subjects. EEG was coregistered with subject-specific MR images and a boundary element model created for dipole source analysis (DSA). When compared with normal control subjects, seven quadriparetics had posteriorly located MPs with finger movements. One paraparetic had a posterior MP with toe movements, but three who could not move the toes had normally located MPs on attempts to move. DSA confirmed the electrical field map distributions of the MPs. We are reporting a reorganization of cortical motor activity to a posterior location after SCI. These results suggest an important role of the somatosensory cortex (S1) in the recovery process after SCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
“Keywords: soft robotics, bio-inspired robotics, wearable robotics, active orthosis, pneumatic artificial muscles (PAMs), soft sensors, feedback control (Some figures may appear in colour only in the online journal)”
BackgroundWall, J. T., Xu, J., & Wang, X. (2002) · Brain Research Reviews · doi:10.1016/s0165-0173(02)00192-3 · Cited by 266
Bio-inspired active soft orthotic device for ankle foot pathologies
Park, Y.-L., Chen, B.-R., Young, D., Stirling, L., Wood, R. J., Goldfield, E., & Nagpal, R. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094933 · Cited by 130
Birch, G. E., Bozorgzadeh, Z., & Mason, S. G. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806839 · Cited by 97
“[16], [17] report normal function with minor ( 1 cm) caudal shift.”
BackgroundSelfslagh, A., Shokur, S., Campos, D. S. F., Donati, A. R. C., Almeida, S., Yamauti, S. Y., Coelho, D. B., Bouri, M., & Nicolelis, M. A. L. (2019) · Scientific Reports · doi:10.1038/s41598-019-43041-9 · Cited by 78
Metadata
- Authors
- Green, J. B., Sora, E., Bialy, Y., Ricamato, A., & Thatcher, R. W.
- Venue
- Neurology
- Published
- 1998-04
- Volume
- 50
- Issue
- 4
- Pages
- 1115-1121
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2022715008
- Cited by
- 126
- References
- 0
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cortical sensorimotor reorganization after spinal cord injury: An electroencephalographic study. https://app.cochat.ai/papers/10.1212/wnl.50.4.1115
- The paper
- Green, J. B., Sora, E., Bialy, Y., Ricamato, A., & Thatcher, R. W. (1998). Cortical sensorimotor reorganization after spinal cord injury: An electroencephalographic study. Neurology. https://doi.org/10.1212/wnl.50.4.1115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.