Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Bio-inspired active soft orthotic device for ankle foot pathologies

Park, Yong-Lae, Chen, Bor-rong, Young, Diana, Stirling, Leia, Wood, Robert J., Goldfield, Eugene, Nagpal, Radhika · 2011 · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems

Abstract

We describe the design of an active soft ankle-foot orthotic device powered by pneumatic artificial muscles for treating gait pathologies associated with neuromuscular disorders. The design is inspired by the biological musculoskeletal system of a human foot and a lower leg, and mimics the muscle-tendon-ligament structure. A key feature of the device is that it is fabricated with flexible and soft materials that provide assistance without restricting degrees of freedom at the ankle joint. Three pneumatic artificial muscles assist dorsiflexion as well as inversion and eversion. The prototype is also equipped with various embedded sensors for gait training and gait pattern analysis. The prototype is capable of 12° dorsiflexion from a resting position of an ankle joint and a 20° dorsiflexion from plantarflexion. Results of early feedback control experiments show controllability of ankle joint angles. Ultimately, we envision a system that not only can provide physical support to improve mobility but also can increase safety and stability during walking, while enhancing muscle usage and encouraging rehabilitation.

Overview

Integrity signals

Registry

Crossref · 10.1109/iros.2011.6094933

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Research works printed but not linked: 3

  1. kastner, 1999, What are the benefits of the Otto Bock C-Ieg? A comparative gait analysis of C-Ieg, 3R45 and 3R80 (Was kann das C-Ieg?-Ganganalytischer vergleigh von C-Ieg, 3R45 and 3R80), Med Orthop Tech, 119, 131
  2. dietl, 1997, The application of electronics in prosthetics for lower extremities (Der einsatz von elektronik bei prothesen ZUI versorgung der unteren extremitat), Med Orthop Tech, 117, 31
  3. krebs, 2005, Rehabilitation robotics, orthotics, and prosthetics; chapter 48, Textbook of Neural Repair and Rehabilitation

Cited by

See all 143

Metadata

Authors
Park, Y.-L., Chen, B.-R., Young, D., Stirling, L., Wood, R. J., Goldfield, E., & Nagpal, R.
Affiliations
  • Harvard University (US)
  • Boston Children's Hospital (US)
Venue
2011 IEEE/RSJ International Conference on Intelligent Robots and Systems
Publisher
IEEE
Published
2011-09
Pages
4488-4495
ISSN
2153-0858 (ISSN-L)
OpenAlex
W2112427939
Cited by
130
References
24
Citations by year
2026: 3 · 2025: 6 · 2024: 5 · 2023: 7 · 2022: 5 · 2021: 8 · 2020: 14 · 2019: 9 · 2018: 9 · 2017: 12 · 2016: 12 · 2015: 9 · 2014: 8 · 2013: 11 · 2012: 9
FWCI
20.29
Type
conference paper
Language
en
Open access
closed
Locations
IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
ankle-foot orthosis, pneumatic artificial muscles, soft robotics, biomimetic design, neuromuscular disorders, gait rehabilitation, ankle joint, gait analysis, ankle inversion and eversion, feedback control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bio-inspired active soft orthotic device for ankle foot pathologies. https://app.cochat.ai/papers/10.1109/iros.2011.6094933
The paper
Park, Y.-L., Chen, B.-R., Young, D., Stirling, L., Wood, R. J., Goldfield, E., & Nagpal, R. (2011). Bio-inspired active soft orthotic device for ankle foot pathologies. 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems. https://doi.org/10.1109/iros.2011.6094933

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.