The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Magnetic resonance spectroscopy in AD
Abstract
Ventilation-perfusion (V/Q) scan is an established technique used to monitor lung dysfunction in conditions such as pulmonary embolism.1 However, there are safety concerns regarding its use in several important populations e.g. pregnant women and children. Recent advances have transformed the use of standard clinical MRI equipment in functional lung imaging.2 We recently presented a clinically appropriate dynamic oxygen-enhanced MRI (dOE-MRI) protocol.3 In this work, we interpret dOE-MRI data with a novel physiological model of gas exchange4 that maps the regional distribution of lung ventilation and perfusion, simulating results from a standard V/Q scan. 3D dOE-MRI data were acquired using a 1.5 T Philips scanner as in:3 a 5 min baseline T1 acquisition, followed by a 15 min dynamic acquisition, during which the subject breathed 100% O2 for the middle 5 min. Total scan time is under 30 min throughout which the subject breathes normally. The partial pressure of oxygen in the alveolar compartment was derived as proposed in5 and maps of regional alveolar ventilation and perfusion were produced using a novel two-compartmental model of gas exchange based on.4 Figure 1 shows an example of whole-chest ventilation and perfusion maps from a healthy subject overlaid on a single volume of the acquired MRI (left column). The same maps are displayed as anterior/posterior and right/left anterior oblique projections (right column), equivalent to those achieved with V/Q scintigraphy.1 Estimation of alveolar ventilation and perfusion distribution from 3D dynamic OE-MRI is feasible and can be obtained under clinically acceptable conditions using standard radiological equipment without ionising radiation risks. This approach opens the possibility for regional assessment of lung physiology using a single short scanning session. References 1 Bajc, et al. Eur J Nucl Med Mol Imaging 2009;36(8):1356–70 2 Wild, et al. Insights Imaging 2012;3(4):345–53 3 Ulloa, et al. Proc Intl Soc Mag Reson Med. 2015;23:3973 4 Naish, et al. Proc Intl Soc Mag Reson Med. 2010;18:2516 5 Kershaw, et al. MRM 2010;64:1838–42
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of chemical issues in 1H NMR spectroscopy: N‐acetyl‐l‐aspartate, creatine and choline
Miller, B. L. (1991) · NMR in Biomedicine · doi:10.1002/nbm.1940040203 · Cited by 654
Immunocytochemical localization of N-acetyl-aspartate with monoclonal antibodies
Simmons, M. L., Frondoza, C. G., & Coyle, J. T. (1991) · Neuroscience · doi:10.1016/0306-4522(91)90101-s · Cited by 626
Do defecs in mitochondrial energy metabolism underlie the pathology of neurodegenerative diseases?
Beal, M. F., Hyman, B. T., & Koroshetz, W. (1993) · Trends in Neurosciences · doi:10.1016/0166-2236(93)90117-5 · Cited by 574
Frahm, J., Bruhn, H., Gyngell, M. L., Merboldt, K. D., Hänicke, W., & Sauter, R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910110105 · Cited by 518
Oxidative stress: Free radical production in neural degeneration
Götz, M. E., Künig, G., Riederer, P., & Youdim, M. B. H. (1994) · Pharmacology & Therapeutics · doi:10.1016/0163-7258(94)90055-8 · Cited by 482
Regional metabolic patterns in mild cognitive impairment and Alzheimer’s disease: A 1H MRS study
Kantarci, K., Jack, C. R., Xu, Y. C., Campeau, N. G., O’Brien, P. C., Smith, G. E., Ivnik, R. J., Boeve, B. F., Kokmen, E., Tangalos, E. G., et al. (2000) · Neurology · doi:10.1212/wnl.55.2.210 · Cited by 463
Reversible decreases in N‐acetylaspartate after acute brain injury
Stefano, N. D., Matthews, P. M., & Arnold, D. L. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340511 · Cited by 438
Inhibition of N-acetylaspartate production: implications for 1H MRS studies in vivo.
Bates, T. E., Strangward, M., Keelan, J., Davey, G. P., Munro, P., & Clark, J. B. (1996) · PubMed · Cited by 422
N -Acetylaspartate in neuropsychiatric disorders
Tsai, G., & Coyle, J. T. (1995) · Progress in Neurobiology · doi:10.1016/0301-0082(95)00014-m · Cited by 422
Bitsch, A., Bruhn, H., Vougioukas, V. I., Stringaris, A. K., Lassmann, H., Frahm, J., & Brück, W. (1999) · PubMed Central · Cited by 415
Cited by
Brain reserve and dementia: a systematic review
VALENZUELA, M. J., & SACHDEV, P. (2006) · Psychological Medicine · doi:10.1017/s0033291705006264 · Cited by 932
Self-citationHan, X., M. Holtzman, D., W. McKeel, D., Kelley, J., & Morris, J. C. (2002) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2002.00997.x · Cited by 626
Steen, R. G., Hamer, R. M., & Lieberman, J. A. (2005) · Neuropsychopharmacology · doi:10.1038/sj.npp.1300850 · Cited by 254
Body mass index and magnetic resonance markers of brain integrity in adults
Gazdzinski, S., Kornak, J., Weiner, M. W., & Meyerhoff, D. J. (2008) · Annals of Neurology · doi:10.1002/ana.21377 · Cited by 191
Reduced hippocampal glutamate in Alzheimer disease
Rupsingh, R., Borrie, M., Smith, M., Wells, J. L., & Bartha, R. (2011) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2009.05.002 · Cited by 177
Metadata
- Authors
- Valenzuela, M. J., & Sachdev, P.
- Venue
- Neurology
- Published
- 2001-03-13
- Volume
- 56
- Issue
- 5
- Pages
- 592-598
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W1984229043
- Cited by
- 255
- References
- 59
- FWCI
- 14.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic resonance spectroscopy in AD. https://app.cochat.ai/papers/10.1212/wnl.56.5.592
- The paper
- Valenzuela, M. J., & Sachdev, P. (2001). Magnetic resonance spectroscopy in AD. Neurology. https://doi.org/10.1212/wnl.56.5.592
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.