CoChat

Normal hypocretin-1 levels in Parkinson’s disease patients with excessive daytime sleepiness

Overeem, S., van Hilten, J.J., Ripley, B., Mignot, E., Nishino, S., Lammers, G.J. · 2002 · Neurology
Cited by 130

The DOI matches its Crossref record.

Abstract

AIMS: To develop and validate a rapid and economical semiautomated approach to the measurement of immunostainable tissue components which is applicable to routine diagnostic practice. To apply this approach to the measurement of macrophages in renal biopsy specimens in nephrotic states, as protein in the renal tubules may induce macrophage infiltration, and the morphology of macrophages in tissue sections does not lend itself to cell counting. METHODS: Macrophages were identified by immunostaining with a pan-macrophage marker, followed by digital image capture and analysis using a macro procedure written for the freeware image analysis program NIH-Image. RESULTS: The method was rapid, robust and accurate to within the limits imposed by sampling error inherent in the use of small needle biopsy specimens. Very few macrophages are found in normal kidney (mean volume fraction (+/- 95% confidence limits) 0.04% (0.02%)) but infiltration of macrophages was detected in minimal change nephropathy (0.29% (0.12%)) and in membranous glomerulonephritis (0.42% (0.11%)). A statistically significant correlation was found between macrophage volume fraction and weight of proteinuria in minimal change nephropathy but not in membranous glomerulonephritis. Correlations were found in both diseases between macrophage volume fraction and serum creatinine at time of biopsy. CONCLUSIONS: The equipment is inexpensive and measurement takes less than one minute per biopsy specimen. The results indicate that macrophage infiltration is part of the pathological process in minimal change nephropathy and membranous glomerulonephritis. The correlation with creatinine at time of biopsy suggests that renal impairment in minimal change nephropathy may result from infiltration by immunologically active cells and not merely from haemodynamic changes in nephrons. However, the correlation is not close, indicating that the relation between macrophage infiltration and disease severity is not a simple one.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.58.3.498

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Overeem, S., van Hilten, J. J., Ripley, B., Mignot, E., Nishino, S., & Lammers, G. J.
Venue
Neurology
Published
2002-02-12
Volume
58
Issue
3
Pages
498-499
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W2071482417
Cited by
130
References
0
FWCI
4.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.