Capnography Accurately Detects Apnea During Monitored Anesthesia Care
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
In Brief Apnea and airway obstruction are common during monitored anesthesia care (MAC). Because their early detection is essential, we sought to measure the efficacy of capnography as an indicator of apnea during MAC at a variety of oxygen flow rates compared with thoracic impedance. Anesthesia care providers using standard American Society of Anesthesiologists monitors were blinded to capnography and thoracic impedance monitoring. Ten (26%) of the 39 patients studied developed 20 s of apnea; none was detected by the anesthesia provider, but all were detected by capnography and impedance monitoring. There was no difference in detection rates between the two methods. Higher oxygen flow rates decreased the amplitude of the capnograph but did not interfere with apnea detection. This pilot study revealed that apnea of at least 20 s in duration may occur in every fourth patient undergoing MAC. Although these episodes were undetected by the anesthesia provider, they were reliably detected by both capnography and respiratory plethysmography. Monitoring of nasal end-tidal CO2 is an important way to improve safety in patients undergoing MAC. IMPLICATIONS: Capnography is not a mandatory monitor for monitored anesthesia care procedures, nor is it required for sedation performed outside of the operating room, although there are practice guidelines that suggest that monitoring of ventilatory function be used to reduce the risk of adverse outcomes. Use of capnography can enhance detection of apnea during sedation procedures and potentially improve patient safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practice Guidelines for Sedation and Analgesia by Non-Anesthesiologists
(2002) · Anesthesiology · doi:10.1097/00000542-200204000-00031 · Cited by 1,950
A model to describe the rate of oxyhaemoglobin desaturation during apnoea
Farmery, A. D., & Roe, P. G. (1996) · British Journal of Anaesthesia · doi:10.1093/bja/76.2.284 · Cited by 199 · cited 2×
“For example, Farmery and Roe (17) reported that while patients breathed room air, apnea resulted in Spo2 85% within 60 seconds.”
BackgroundHart, L. S., Berns, S. D., Houck, C. S., et al. (1997) · Pediatric Emergency Care · doi:10.1097/00006565-199706000-00004 · Cited by 148
Tobias, J. D. (1999) · Pediatric Emergency Care · doi:10.1097/00006565-199906000-00002 · Cited by 113
Accuracy of Capnography in Nonintubated Surgical Patients
Liu, S.-Y., Lee, T.-S., & Bongard, F. S. (1992) · CHEST Journal · doi:10.1378/chest.102.5.1512 · Cited by 98 · cited 1×
“Although capnography has been shown to correlate significantly with Paco2 level (8), the reliability of nasal capnography to monitor apnea and airway obstruction has not been examined in MAC/sedated patients, nor has it been compared with plethysmography, the “gold standard.”
BackgroundThe benefits and pitfalls of pulse oximetry.
Hutton, P., & Clutton-Brock, T. (1993) · BMJ · doi:10.1136/bmj.307.6902.457 · Cited by 91
Wiklund, L., Hök, B., Ståhl, K., & Jordeby-Jönsson, A. (1994) · Journal of Clinical Anesthesia · doi:10.1016/0952-8180(94)90056-6 · Cited by 88
A comparison of conventional versus electronic monitoring of sedated pediatric dental patients.
Croswell, R. J., Dilley, D. C., Lucas, W. J., & Vann, W. F. (1995) · PubMed · Cited by 84
Freundlich, J. J., & Erickson, J. C. (1974) · CHEST Journal · doi:10.1378/chest.65.2.181 · Cited by 31
Cited by
Clinical Policy: Procedural Sedation and Analgesia in the Emergency Department
Godwin, S. A., Burton, J. H., Gerardo, C. J., Hatten, B. W., Mace, S. E., Silvers, S. M., & Fesmire, F. M. (2014) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2013.10.015 · Cited by 642
Procedural sedation and analgesia in children
Krauss, B., & Green, S. M. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68230-5 · Cited by 564
Injury and Liability Associated with Monitored Anesthesia Care: A Closed Claims Analysis
Bhananker, S. M., Posner, K. L., Cheney, F. W., Caplan, R. A., Lee, L. A., & Domino, K. B. (2006) · Anesthesiology · doi:10.1097/00000542-200602000-00005 · Cited by 399
Jarzyna, D., Jungquist, C. R., Pasero, C., Willens, J. S., Nisbet, A., Oakes, L., Dempsey, S. J., Santangelo, D., & Polomano, R. C. (2011) · Pain Management Nursing · doi:10.1016/j.pmn.2011.06.008 · Cited by 253
Overdyk, F. J., Carter, R., Maddox, R. R., Callura, J., Herrin, A. E., & Henriquez, C. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269489.26048.63 · Cited by 191
“inaccurate in the conscious sedation setting (16,17)”
Burton, J. H., Harrah, J. D., Germann, C. A., & Dillon, D. C. (2006) · Academic Emergency Medicine · doi:10.1197/j.aem.2005.12.017 · Cited by 177
“Ventilation monitoring by clinical observation is also routine during PSA; however, recent studies have questioned the sensitivity of this practice for early changes in respiratory status.(2,3) In the operating room, end-tidal carbon dioxide (ETCO2) monitoring is standard practice for ventilation monitoring and is the…”
MethodCapnography for Procedural Sedation and Analgesia in the Emergency Department
Krauss, B., & Hess, D. R. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.10.016 · Cited by 176
“Capnography may be more sensitive than clinical assessment of ventilation in detection of apnea.(12,29,34-36) In a recent study,”
BackgroundCapnography enhances surveillance of respiratory events during procedural sedation: a meta-analysis
Waugh, J. B., Epps, C. A., & Khodneva, Y. A. (2011) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2010.08.012 · Cited by 163
“Soto et al (2004) [9]: This study started with the premise that apnea and airway obstruction are common during monitored anesthesia care.”
BackgroundThornlow, D. K., Anderson, R., & Oddone, E. (2009) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.06.015 · Cited by 74
“…of respiratory rate and depth for bradypnea or tachypnea is necessary and may be supplemented by pulse oximetry and capnography readings in higher risk patients, although lack of correlation among the readings from these different methods has been reported (Overdyk et al., 2006; Soto et al., 2004).”
Background
Metadata
- Authors
- Soto, R. G., Fu, E. S., Vila, H., & Miguel, R. V.
- Venue
- Anesthesia & Analgesia
- Published
- 2004-08
- Volume
- 99
- Issue
- 2
- Pages
- 379-382
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2030730441
- Cited by
- 189
- References
- 11
- FWCI
- 11.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.