The DOI matches its Crossref record.
Cervical Spine Motion: A Fluoroscopic Comparison During Intubation with Lighted Stylet, GlideScope, and Macintosh Laryngoscope
Abstract
In Brief The question of which is the optimum technique to intubate the trachea in a patient who may have a cervical(C)-spine injury remains unresolved. We compared, using fluoroscopic video, C-spine motion during intubation for Macintosh 3 blade, GlideScope®, and Intubating Lighted Stylet, popularly known as the Lightwand or Trachlight®. Thirty-six healthy patients were randomized to participate in a crossover trial of either Lightwand or GlideScope to Macintosh laryngoscopy, with in-line stabilization. C-spine motion was examined at the Occiput-C1 junction, C1-2 junction, C2-5 motion segment, and C5-thoracic motion segment during manual ventilation via bag-mask, laryngoscopy, and intubation. Time to intubate was also measured. C-spine motion during bag-mask ventilation was 82% less at the four motion segments studied than during Macintosh laryngoscopy (P < 0.001). C-spine motion using the Lightwand was less than during Macintosh laryngoscopy, averaging 57% less at the four motion segments studied (P < 0.03). There was no significant difference in time to intubate between the Lightwand and the Macintosh blade. C-spine motion was reduced 50% at the C2-5 segment using the GlideScope (P < 0.04) but unchanged at the other segments. Laryngoscopy with GlideScope took 62% longer than with the Macintosh blade (P < 0.01). Thus, the Lightwand (Intubating Lighted Stylet) is associated with reduced C-spine movement during endotracheal intubation compared with the Macintosh laryngoscope. IMPLICATIONS: The question of which is the optimum technique to intubate the trachea of a patient who may have a cervical(C)-spine injury remains unresolved. Using fluoroscopic video, C-spine motion during intubation was compared for Macintosh 3 blade, GlideScope, and Lightwand use. The Lightwand is associated with reduced C-spine movement during intubation compared to Macintosh laryngoscope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Airway management in adults after cervical spine trauma
Crosby, E. T., & Warltier, D. C. (2006) · Anesthesiology · doi:10.1097/00000542-200606000-00026 · Cited by 401
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Griesdale, D. E. G., Liu, D., McKinney, J., & Choi, P. T. (2012) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-011-9620-5 · Cited by 363
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., Schofield-Robinson, O. J., & Smith, A. F. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex228 · Cited by 359
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Self-citation
Metadata
- Authors
- Turkstra, T. P., Craen, R. A., Pelz, D. M., & Gelb, A. W.
- Venue
- Anesthesia & Analgesia
- Published
- 2005-09
- Volume
- 101
- Issue
- 3
- Pages
- 910-915
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1971588014
- Cited by
- 238
- References
- 0
- FWCI
- 11.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cervical Spine Motion: A Fluoroscopic Comparison During Intubation with Lighted Stylet, GlideScope, and Macintosh Laryngoscope. https://app.cochat.ai/papers/10.1213/01.ane.0000166975.38649.27
- The paper
- Turkstra, T. P., Craen, R. A., Pelz, D. M., & Gelb, A. W. (2005). Cervical Spine Motion: A Fluoroscopic Comparison During Intubation with Lighted Stylet, GlideScope, and Macintosh Laryngoscope. Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000166975.38649.27
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.