CoChat

What Is the Best Site for Measuring the Effect of Ventilation on the Pulse Oximeter Waveform?

Shelley, Kirk H., Jablonka, Denis H., Awad, Aymen A., Stout, Robert G., Rezkanna, Hoda, Silverman, David G. · 2006 · Anesthesia & Analgesia
Cited by 99

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In Brief The cardiac pulse is the predominant feature of the pulse oximeter (plethysmographic) waveform. Less obvious is the effect of ventilation on the waveform. There have been efforts to measure the effect of ventilation on the waveform to determine respiratory rate, tidal volume, and blood volume. We measured the relative strength of the effect of ventilation on the reflective plethysmographic waveform at three different sites: the finger, ear, and forehead. The plethysmographic waveforms from 18 patients undergoing positive pressure ventilation during surgery and 10 patients spontaneously breathing during renal dialysis were collected. The respiratory signal was isolated from the waveform using spectral analysis. It was found that the respiratory signal in the pulse oximeter waveform was more than 10 times stronger in the region of the head when compared with the finger. This was true with both controlled positive pressure ventilation and spontaneous breathing. A significant correlation was demonstrated between the estimated blood loss from surgical procedures and the impact of ventilation on ear plethysmographic data (rs = 0.624, P = 0.006). IMPLICATIONS: The photoplethysmograph can be used to measure the effects of ventilation on the pulse. As measured by spectral analysis the effect of ventilation was 10 times stronger in the ear and forehead compared with the finger and may be preferable for monitoring respiratory rate and changes in intravascular volume status.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/01.ane.0000222477.67637.17

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 99

Metadata

Authors
Shelley, K. H., Jablonka, D. H., Awad, A. A., Stout, R. G., Rezkanna, H., & Silverman, D. G.
Venue
Anesthesia & Analgesia
Published
2006-08
Volume
103
Issue
2
Pages
372-377
ISSN
0003-2999 (ISSN-L)
OpenAlex
W1993871899
Cited by
99
References
2
FWCI
5.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: What Is the Best Site for Measuring the Effect of Ventilation on the Pulse Oximeter Waveform? https://app.cochat.ai/papers/10.1213/01.ane.0000222477.67637.17
The paper
Shelley, K. H., Jablonka, D. H., Awad, A. A., Stout, R. G., Rezkanna, H., & Silverman, D. G. (2006). What Is the Best Site for Measuring the Effect of Ventilation on the Pulse Oximeter Waveform? Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000222477.67637.17

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.