The DOI matches its Crossref record.
Takuo Aoyagi: Discovery of Pulse Oximetry
Abstract
In Brief In the 1930s and 1940s, photo cells permitted German, English, and American physiologists to construct ear oximeters with red and infrared light, requiring calibration. In 1940 Squire recognized that changes of red and infrared light transmission caused by pneumatic tissue compression permitted saturation to be computed. In 1949 Wood used this idea to compute absolute saturation continuously from the ratios of optical density changes with pressure in an ear oximeter. In 1972 Takuo Aoyagi, an electrical engineer at Nihon Kohden company in Tokyo, was interested in measuring cardiac output noninvasively by the dye dilution method using a commercially available ear oximeter. He balanced the red and infrared signals to cancel the pulse noise which prevented measuring the dye washout accurately. He discovered that changes of oxygen saturation voided his pulse cancellation. He then realized that these pulsatile changes could be used to compute saturation from the ratio of ratios of pulse changes in the red and infrared. His ideas, equations and instrument were adapted, improved and successfully marketed by Minolta about 1978, stimulating other firms to further improve and market pulse oximeters worldwide in the mid 1980s. Dr. Aoyagi and associates provided a detailed history for this paper. IMPLICATIONS: The development of pulse oximetry by Takuo Aoyagi is arguably the greatest advance inpatient safety in the history of Anesthesiology. The story of Aoyagi’s discovery and that of earlier oximeter concepts is covered in this historical review.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Conflict of Interest in Medical Research, Education, and Practice
(2009) · National Academies Press eBooks · doi:10.17226/12598 · Cited by 807
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
Metadata
- Authors
- Severinghaus, J. W.
- Venue
- Anesthesia & Analgesia
- Published
- 2007-12
- Volume
- 105
- Issue
- 6
- Pages
- S1-S4
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1967412410
- Cited by
- 161
- References
- 0
- FWCI
- 61.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Takuo Aoyagi: Discovery of Pulse Oximetry. https://app.cochat.ai/papers/10.1213/01.ane.0000269514.31660.09
- The paper
- Severinghaus, J. W. (2007). Takuo Aoyagi: Discovery of Pulse Oximetry. Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000269514.31660.09
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.