Temporal Artery Versus Bladder Thermometry During Perioperative and Intensive Care Unit Monitoring
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Core temperature measurements are an important component of perioperative patient monitoring. It is fairly easy to obtain core temperature measurements invasively in anesthetized patients. However, such measurements are more difficult to obtain noninvasively in awake patients. Recently, a new version of a temporal artery thermometer for noninvasive core temperature measurements (TemporalScanner TAT-5000) was introduced with accuracy and precision advertised as being comparable to invasive core temperature measurements. In this study, we sought to determine if this new thermometer is an acceptable substitute for invasive bladder temperature measurement. METHODS: In 35 patients undergoing neurosurgical interventions and 35 patients in the neurosurgical intensive care unit, measurements from the temporal artery thermometer were compared with those from a bladder thermometer. Four measurements were obtained from each patient. RESULTS: Overall 280 measurement pairs were obtained. The mean bias between the methods was 0.07 degrees C +/- 0.79 degrees C; the limits of agreement were approximately 3 times greater than the a priori defined limit of +/-0.5 degrees C (-1.48 to 1.62). The sensitivity for detecting fever (core temperature >37.8 degrees C) using the temporal artery thermometer was 0.72, and the specificity was 0.97. The positive predictive value for fever was 0.89; the negative predictive value was 0.94. The sensitivity for detecting hypothermia (core temperature <35.5 degrees C) was 0.29, and the specificity was 0.95. The positive predictive value for hypothermia was 0.31, and the negative predictive value was 0.95. CONCLUSIONS: The results of this study do not support the use of temporal artery thermometry for perioperative core temperature monitoring; the temporal artery thermometer does not provide information that is an adequate substitute for core temperature measurement by a bladder thermometer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Circadian changes in the sweating-to-vasoconstriction interthreshold range
Tayefeh, F., Plattner, O., Sessler, D. I., Ikeda, T., & Marder, D. (1998) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/s004240050530 · Cited by 79 · cited 1×
“5°C, as this range is within the range of normal circadian body temperature variations (28,32) and is also consistent with the bias found when comparing different standard core temperature measurement sites (33,34).”
Cited by
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Dow, J., Giesbrecht, G. G., Danzl, D. F., Brugger, H., Sagalyn, E. B., Walpoth, B., Auerbach, P. S., McIntosh, S. E., Némethy, M., McDevitt, M., et al. (2019) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2019.10.002 · Cited by 195
““Temporal artery” thermometers, used on the skin surface, do not provide accurate temperature measurements in hypothermia.(36)”
BackgroundAn Evaluation of a Zero-Heat-Flux Cutaneous Thermometer in Cardiac Surgical Patients
Eshraghi, Y., Nasr, V., Parra-Sanchez, I., Van Duren, A., Botham, M., Santoscoy, T., & Sessler, D. I. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000319 · Cited by 161
Temperature measurements with a temporal scanner: systematic review and meta-analysis
Geijer, H., Udumyan, R., Lohse, G., & Nilsagård, Y. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-009509 · Cited by 66
The accuracy of a disposable noninvasive core thermometer
Kimberger, O., Saager, L., Egan, C., Sanchez, I. P., Dizili, S., Koch, J., & Kurz, A. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0047-z · Cited by 30
Self-citation
Metadata
- Authors
- Kimberger, O., Cohen, D., Illievich, U., & Lenhardt, R.
- Venue
- Anesthesia & Analgesia
- Published
- 2007-10
- Volume
- 105
- Issue
- 4
- Pages
- 1042-1047
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2081214428
- Cited by
- 71
- References
- 2
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.