First-Attempt Intubation Success of Video Laryngoscopy in Patients with Anticipated Difficult Direct Laryngoscopy: A Multicenter Randomized Controlled Trial Comparing the C-MAC D-Blade Versus the GlideScope in a Mixed Provider and Diverse Patient Population
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Intubation success in patients with predicted difficult airways is improved by video laryngoscopy. In particular, acute-angle video laryngoscopes are now frequently chosen for endotracheal intubation in these patients. However, there is no evidence concerning whether different acute-angle video laryngoscopes can be used interchangeably in this scenario and would allow endotracheal intubation with the same success rate. We therefore tested whether first-attempt intubation success is similar when using a newly introduced acute-angle blade, that is an element of an extended airway management system (C-MAC D-Blade) compared with a well-established acute-angle video laryngoscope (GlideScope). METHODS: In this large multicentered prospective randomized controlled noninferiority trial, patients requiring general anesthesia for elective surgery and presenting with clinical predictors of difficult laryngoscopy were randomly assigned to intubation using either the C-MAC D-Blade or the GlideScope video laryngoscope. The hypothesis was that first-attempt intubation success using the new device (D-Blade) is no >4% less than the established device (GlideScope), which would determine noninferiority of the new instrument versus the established instrument. The secondary outcomes we observed included intubation success with multiple attempts and airway-related complications within 7 days of enrollment. RESULTS: Eleven hundred patients were randomly assigned to either video laryngoscope. Intubation success rate on first attempt was 96.2% in the GlideScope group and 93.4% in the C-MAC D-Blade group. Although the absolute difference between the 2 groups was only 2.8%, the 90.35% upper confidence limit of the difference exceeded the predefined margin (4.98%), indicating a rejection of the noninferiority hypothesis for first-attempt intubation success. For attending anesthesiologists, and upon multiple attempts, intubation success did not differ between systems. Pharyngeal injury was noted in 1% of the patients, and the incidence did not differ between interventional groups. CONCLUSIONS: Head-to-head comparison in this large multicenter trial revealed that the newly introduced C-MAC D-Blade does not yield the same first-attempt intubation success as the GlideScope in patients with predicted difficult laryngoscopy except in the hands of attending anesthesiologists. Additional research would be necessary to identify potential causes for this difference. Intubation success rates were very high with both systems, indicating that acute-angle video laryngoscopy is an exceptionally successful strategy for the initial approach to endotracheal intubation in patients with predicted difficult laryngoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Multiple Testing Procedure for Clinical Trials
O'Brien, P. C., & Fleming, T. R. (1979) · Biometrics · doi:10.2307/2530245 · Cited by 3,311
Discrete sequential boundaries for clinical trials
GORDON LAN, K. K., & DEMETS, D. L. (1983) · Biometrika · doi:10.1093/biomet/70.3.659 · Cited by 2,310
Discrete Sequential Boundaries for Clinical Trials
Lan, K. K. G., & DeMets, D. L. (1983) · Biometrika · doi:10.2307/2336502 · Cited by 2,310
Cited by
Kleine-Brueggeney, M., Greif, R., Schoettker, P., Savoldelli, G. L., Nabecker, S., & Theiler, L. G. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew058 · Cited by 216
“Time to advance tube {s; median (25th; 75th percentile) [range]} 36 (28; 61) [8–154] 40 (29; 71) [10–157] 33 (26; 51) [6–147] 27 (19; 36) [6–148] 50 (27; 88) [14–138] 31 (24; 46) [4–140] <0.”
Strategies for the prevention of airway complications – a narrative review
Cook, T. M. (2018) · Anaesthesia · doi:10.1111/anae.14123 · Cited by 167
“Conversely, a recent RCT suggested a modest increase in first-time success during use of the Glidescope (Verathon) compared with the C-MAC Dblade (Karl Storz GmbH), although this difference was not sustained after multiple attempts or in the hands of senior staff [85].”
ResultGu, Y., Robert, J., Kovacs, G., Milne, A. D., Morris, I., Hung, O., MacQuarrie, K., Mackinnon, S., & Adam Law, J. (2016) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-016-0654-6 · Cited by 57
Limitations of videolaryngoscopy
Norris, A., & Heidegger, T. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew122 · Cited by 38
“showed a first-attempt intubation success of 96% and 93%, respectively.(13) Although patients with limited mouth opening were included the majority were primarily obese with an increased neck circumference.”
Metadata
- Authors
- Aziz, M. F., Abrons, R. O., Cattano, D., Bayman, E. O., Swanson, D. E., Hagberg, C. A., Todd, M. M., & Brambrink, A. M.
- Venue
- Anesthesia & Analgesia
- Published
- 2016-03
- Volume
- 122
- Issue
- 3
- Pages
- 740-750
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2412495152
- Cited by
- 96
- References
- 3
- FWCI
- 12.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: First-Attempt Intubation Success of Video Laryngoscopy in Patients with Anticipated Difficult Direct Laryngoscopy: A Multicenter Randomized Controlled Trial Comparing the C-MAC D-Blade Versus the GlideScope in a Mixed Provider and Diverse Patient Population. https://app.cochat.ai/papers/10.1213/ane.0000000000001084
- The paper
- Aziz, M. F., Abrons, R. O., Cattano, D., Bayman, E. O., Swanson, D. E., Hagberg, C. A., Todd, M. M., & Brambrink, A. M. (2016). First-Attempt Intubation Success of Video Laryngoscopy in Patients with Anticipated Difficult Direct Laryngoscopy: A Multicenter Randomized Controlled Trial Comparing the C-MAC D-Blade Versus the GlideScope in a Mixed Provider and Diverse Patient Population. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000001084
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.