Diagnostic Accuracy of Point-of-Care Gastric Ultrasound
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Pulmonary aspiration of gastric contents is associated with significant perioperative morbidity and mortality. Previous studies have investigated the validity, reliability, and possible clinical impact of gastric ultrasound for the assessment of gastric content at the bedside. In the present study, we examined the accuracy (evaluated as sensitivity, specificity, and likelihood ratios) of point-of-care gastric ultrasound to detect a “full stomach” in a simulated scenario of clinical equipoise. METHODS: After a minimum fasting period of 8 hours, 40 healthy volunteers were randomized in a 1:1 ratio to either remain fasted or ingest a standardized quantity of clear fluid or solid. Each subject was randomized twice on 2 independent study sessions at least 24 hours apart. A gastric ultrasound examination was performed by a blinded sonographer following a standardized scanning protocol. Using a combination of qualitative and quantitative findings, the result was summarized in a dichotomous manner as positive (any solid or >1.5 mL/kg of clear fluid) or negative (no solid and ≤1.5 mL/kg of clear fluid) for full stomach. RESULTS: Data from 80 study sessions were analyzed. In this simulated clinical scenario with a pretest probability of 50%, point-of-care gastric ultrasound had a sensitivity of 1.0 (95% confidence interval [CI], 0.925–1.0), a specificity of 0.975 (95% CI, 0.95–1.0), a positive likelihood ratio of 40.0 (95% CI, 10.33–∞), a negative likelihood ratio of 0 (95% CI, 0–0.072), a positive predictive value of 0.976 (95% CI, 0.878–1.0), and a negative predictive value of 1.0 (95% CI, 0.92–1.0). CONCLUSIONS: Our results suggest that bedside gastric ultrasound is highly sensitive and specific to detect or rule out a full stomach in clinical scenarios in which the presence of gastric content is uncertain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
(2017) · Anesthesiology · doi:10.1097/aln.0000000000001452 · Cited by 1,114
(1975) · New England Journal of Medicine · doi:10.1056/nejm197507312930513 · Cited by 1,017
Van de Putte, P., Vernieuwe, L., Jerjir, A., Verschueren, L., Tacken, M., & Perlas, A. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aew435 · Cited by 176
Self-citation
Cited by
Frykholm, P., Disma, N., Andersson, H., Beck, C., Bouvet, L., Cercueil, E., Elliott, E., Hofmann, J., Isserman, R., Klaucane, A., et al. (2022) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001599 · Cited by 266
Glucagon-Like Peptide-1 Receptor Agonist Use and Residual Gastric Content Before Anesthesia
Sen, S., Potnuru, P. P., Hernandez, N., Goehl, C., Praestholm, C., Sridhar, S., & Nwokolo, O. O. (2024) · JAMA Surgery · doi:10.1001/jamasurg.2024.0111 · Cited by 202
Sherwin, M., Hamburger, J., Katz, D., & DeMaria, S. (2023) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-023-02549-5 · Cited by 132
“There is mounting evidence to support the role of bedside gastric ultrasound as a highly sensitive and specific tool to positively identify or rule out a full stomach and guide anesthetic management to prevent pulmonary aspiration.(14,15) To date, no evaluations of residual stomach contents using gastric ultrasound ha…”
BackgroundNersessian, R. S. F., da Silva, L. M., Carvalho, M. A. S., Silveira, S. Q., Abib, A. C. V., Bellicieri, F. N., Lima, H. O., Ho, A. M. ‐., Anjos, G. S., & Mizubuti, G. B. (2024) · Anaesthesia · doi:10.1111/anae.16454 · Cited by 69
“Gastric ultrasound is highly sensitive and speci fi c in ruling in or out a `full stomach´ in scenarios where residual gastric content is uncertain [13] and, in trained hands, it allows for an individualised pre-operative bedside assessment of patients receiving semaglutide therapy [1, 10 – 12 We…”
Girón-Arango, L., & Perlas, A. (2024) · A&A Practice · doi:10.1213/xaa.0000000000001751 · Cited by 19
Self-citation
Metadata
- Authors
- Kruisselbrink, R., Gharapetian, A., Chaparro, L. E., Ami, N., Richler, D., Chan, V. W. S., & Perlas, A.
- Venue
- Anesthesia & Analgesia
- Published
- 2019-01
- Volume
- 128
- Issue
- 1
- Pages
- 89-95
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2795951948
- Cited by
- 161
- References
- 7
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Accuracy of Point-of-Care Gastric Ultrasound. https://app.cochat.ai/papers/10.1213/ane.0000000000003372
- The paper
- Kruisselbrink, R., Gharapetian, A., Chaparro, L. E., Ami, N., Richler, D., Chan, V. W. S., & Perlas, A. (2019). Diagnostic Accuracy of Point-of-Care Gastric Ultrasound. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000003372
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.