A Randomized Trial of Continuous Noninvasive Blood Pressure Monitoring During Noncardiac Surgery
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Intraoperative hypotension is associated with postoperative mortality. Early detection of hypotension by continuous hemodynamic monitoring might prompt timely therapy, thereby reducing intraoperative hypotension. We tested the hypothesis that continuous noninvasive blood pressure monitoring reduces intraoperative hypotension. METHODS: Patients ≥45 years old with American Society of Anesthesiologists physical status III or IV having moderate-to-high-risk noncardiac surgery with general anesthesia were included. All participating patients had continuous noninvasive hemodynamic monitoring using a finger cuff (ClearSight, Edwards Lifesciences, Irvine, CA) and a standard oscillometric cuff. In half the patients, randomly assigned, clinicians were blinded to the continuous values, whereas the others (unblinded) had access to continuous blood pressure readings. Continuous pressures in both groups were used for analysis. Time-weighted average for mean arterial pressure <65 mm Hg was compared using 2-sample Wilcoxon rank-sum tests and Hodges Lehmann estimation of location shift with corresponding asymptotic 95% CI. RESULTS: Among 320 randomized patients, 316 were included in the intention-to-treat analysis. With 158 patients in each group, those assigned to continuous blood pressure monitoring had significantly lower time-weighted average mean arterial pressure <65 mm Hg, 0.05 [0.00, 0.22] mm Hg, versus intermittent blood pressure monitoring, 0.11 [0.00, 0.54] mm Hg (P = .039, significance criteria P < .048). CONCLUSIONS: Continuous noninvasive hemodynamic monitoring nearly halved the amount of intraoperative hypotension. Hypotension reduction with continuous monitoring, while statistically significant, is currently of uncertain clinical importance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Walsh, M., Devereaux, P. J., Garg, A. X., Kurz, A., Turan, A., Rodseth, R. N., Cywinski, J., Thabane, L., & Sessler, D. I. (2013) · Anesthesiology · doi:10.1097/aln.0b013e3182a10e26 · Cited by 1,475
Self-citationSalmasi, V., Maheshwari, K., Yang, D., Mascha, E. J., Singh, A., Sessler, D. I., & Kurz, A. (2017) · Anesthesiology · doi:10.1097/aln.0000000000001432 · Cited by 1,104
Self-citationDevelopment and Psychometric Evaluation of a Postoperative Quality of Recovery Score: The QoR-15
Stark, P. A., Myles, P. S., & Burke, J. A. (2013) · Anesthesiology · doi:10.1097/aln.0b013e318289b84b · Cited by 962
Futier, E., Lefrant, J.-Y., Guinot, P.-G., Godet, T., Lorne, E., Cuvillon, P., Bertran, S., Leone, M., Pastene, B., Piriou, V., et al. (2017) · JAMA · doi:10.1001/jama.2017.14172 · Cited by 917
Anesthetic Management and One-Year Mortality After Noncardiac Surgery
Monk, T. G., Saini, V., Weldon, B. C., & Sigl, J. C. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000147519.82841.5e · Cited by 890
Association of Intraoperative Hypotension with Acute Kidney Injury after Elective Noncardiac Surgery
Sun, L. Y., Wijeysundera, D. N., Tait, G. A., & Beattie, W. S. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000765 · Cited by 776
Bijker, J. B., van Klei, W. A., Kappen, T. H., van Wolfswinkel, L., Moons, K. G. M., & Kalkman, C. J. (2007) · Anesthesiology · doi:10.1097/01.anes.0000270724.40897.8e · Cited by 710
Monk, T. G., Bronsert, M. R., Henderson, W. G., Mangione, M. P., Sum-Ping, S. T. J., Bentt, D. R., Nguyen, J. D., Richman, J. S., Meguid, R. A., & Hammermeister, K. E. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000756 · Cited by 610
Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824f94ed · Cited by 292
Cited by
Wijnberge, M., Geerts, B. F., Hol, L., Lemmers, N., Mulder, M. P., Berge, P., Schenk, J., Terwindt, L. E., Hollmann, M. W., Vlaar, A. P., et al. (2020) · JAMA · doi:10.1001/jama.2020.0592 · Cited by 586
Thompson, A., Fleischmann, K. E., Smilowitz, N. R., de las Fuentes, L., Mukherjee, D., Aggarwal, N. R., Ahmad, F. S., Allen, R. B., Altin, S. E., Auerbach, A., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001285 · Cited by 365
Ruetzler, K., Smilowitz, N. R., Berger, J. S., Devereaux, P. J., Maron, B. A., Newby, L. K., de Jesus Perez, V., Sessler, D. I., Wijeysundera, D. N., & on behalf of the American Heart Association Council on Cardiopulmonary, C. C. (2021) · Circulation · doi:10.1161/cir.0000000000001024 · Cited by 279
Self-citationDavies, S. J., Vistisen, S. T., Jian, Z., Hatib, F., & Scheeren, T. W. L. (2020) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004121 · Cited by 219
How to measure blood pressure using an arterial catheter: a systematic 5-step approach
Saugel, B., Kouz, K., Meidert, A. S., Schulte-Uentrop, L., & Romagnoli, S. (2020) · Critical Care · doi:10.1186/s13054-020-02859-w · Cited by 214
Thompson, A., Fleischmann, K. E., Smilowitz, N. R., de las Fuentes, L., Mukherjee, D., Aggarwal, N. R., Ahmad, F. S., Allen, R. B., Altin, S. E., Auerbach, A., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.06.013 · Cited by 209
Perioperative Blood Pressure Management
Saugel, B., & Sessler, D. I. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003610 · Cited by 191
“In pilot randomized trials, continuous noninvasive finger cuff blood pressure monitoring reduced intraoperative hypotension compared to intermittent oscillometric blood pressure monitoring.(24,42) Other blood pressure monitoring methods—such as the hydraulic coupling method,(43) applanation tonometry,(44) the pulse wa…”
BackgroundMethodSelf-citationMaheshwari, K., Shimada, T., Yang, D., Khanna, S., Cywinski, J. B., Irefin, S. A., Ayad, S., Turan, A., Ruetzler, K., Qiu, Y., et al. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003557 · Cited by 187
Self-citationSaugel, B., Fletcher, N., Gan, T. J., Grocott, M. P. W., Myles, P. S., Sessler, D. I., Auzinger, G., Chappell, D., Gan, T. J., Edwards, M., et al. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.04.046 · Cited by 180
Self-citation
Metadata
- Authors
- Maheshwari, K., Khanna, S., Bajracharya, G. R., Makarova, N., Riter, Q., Raza, S., Cywinski, J. B., Argalious, M., Kurz, A., & Sessler, D. I.
- Venue
- Anesthesia & Analgesia
- Published
- 2018-08
- Volume
- 127
- Issue
- 2
- Pages
- 424-431
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2809635433
- Cited by
- 173
- References
- 16
- FWCI
- 12.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.