Evaluation and Management of the Physiologically Difficult Airway: Consensus Recommendations From Society for Airway Management
The DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.
Abstract
Multiple international airway societies have created guidelines for the management of the difficult airway. In critically ill patients, there are physiologic derangements beyond inadequate airway protection or hypoxemia. These risk factors contribute to the “physiologically difficult airway” and are associated with complications including cardiac arrest and death. Importantly, they are largely absent from international guidelines. Thus, we created management recommendations for the physiologically difficult airway to provide practical guidance for intubation in the critically ill. Through multiple rounds of in-person and telephone conferences, a multidisciplinary working group of 12 airway specialists (Society for Airway Management’s Special Projects Committee) over a time period of 3 years (2016–2019) reviewed airway physiology topics in a modified Delphi fashion. Consensus agreement with the following recommendations among working group members was generally high with 80% of statements showing agreement within a 10% range on a sliding scale from 0% to 100%. We limited the scope of this analysis to reflect the resources and systems of care available to out-of-operating room adult airway providers. These recommendations reflect the practical application of physiologic principles to airway management available during the analysis time period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Updated by the Committee on Standards and Practice Parameters, Apfelbaum, J. L., Hagberg, C. A., Caplan, R. A., Blitt, C. D., Connis, R. T., Nickinovich, D. G., Hagberg, C. A., The previous update was developed by the American Society of Anesthesiologists Task Force on Difficult Airway Management, Caplan, R. A., et al. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31827773b2 · Cited by 2,559
National Hospital Ambulatory Medical Care Survey: 1994 emergency department summary.
Stussman, B. J. (1996) · PubMed · Cited by 2,232
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Emergency Tracheal Intubation: Complications Associated with Repeated Laryngoscopic Attempts
Mort, T. C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000122825.04923.15 · Cited by 995 · cited 1×
“14.”
Guidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
Patel, A., & Nouraei, S. A. R. (2015) · Anaesthesia · doi:10.1111/anae.12923 · Cited by 825
Harjola, V.-P., Mebazaa, A., Čelutkienė, J., Bettex, D., Bueno, H., Chioncel, O., Crespo-Leiro, M. G., Falk, V., Filippatos, G., Gibbs, S., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.478 · Cited by 720
Schwartz, D. E., Matthay, M. A., & Cohen, N. H. (1995) · Anesthesiology · doi:10.1097/00000542-199502000-00007 · Cited by 676 · cited 1×
“55,56 As few as 10 minutes of hypotension can lead to poor outcomes in high-risk patients.”
BackgroundJaber, S., Amraoui, J., Lefrant, J.-Y., Arich, C., Cohendy, R., Landreau, L., Calvet, Y., Capdevila, X., Mahamat, A., & Eledjam, J.-J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000233879.58720.87 · Cited by 675
Predictors of Hypotension After Induction of General Anesthesia
Reich, D. L., Hossain, S., Krol, M., Baez, B., Patel, P., Bernstein, A., & Bodian, C. A. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000175214.38450.91 · Cited by 601 · cited 3×
“Regarding DSI, we recommend using small doses of ketamine (10–20 mg aliquots) or dex-medetomidine to avoid apnea from a dissociative dose.”
Background
Cited by
Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Kovacs, G., Lemay, F., Noppens, R., et al. (2021) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-021-02008-z · Cited by 203
Ahmad, I., El-Boghdadly, K., Iliff, H., Dua, G., Higgs, A., Huntington, M., Mir, F., Nouraei, S. A. R., O'Sullivan, E. P., Patel, A., et al. (2026) · British Journal of Anaesthesia · doi:10.1016/j.bja.2025.10.006 · Cited by 182
Metadata
- Authors
- Kornas, R. L., Owyang, C. G., Sakles, J. C., Foley, L. J., Mosier, J. M., & on behalf of the Society for Airway Management’s Special Projects Committee
- Venue
- Anesthesia & Analgesia
- Published
- 2020-10-14
- Volume
- 132
- Issue
- 2
- Pages
- 395-405
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W3092873692
- Cited by
- 177
- References
- 82
- FWCI
- 24.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.