Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Cardiac Output Measurement in Patients Undergoing Liver Transplantation: Pulmonary Artery Catheter Versus Uncalibrated Arterial Pressure Waveform Analysis

Matthieu, Biais, Karine, Nouette-Gaulain, Vincent, Cottenceau, Alain, Vallet, François, Cochard Jean, Philippe, Revel, François, Sztark·2008·Anesthesia & Analgesia

Abstract

BACKGROUND: Cardiac output (CO) and invasive hemodynamic measurements are useful during liver transplantation. The pulmonary artery catheter (PAC) is commonly used for these patients, despite the potential complications. Recently, a less invasive device (Vigileo/FloTrac) became available, which estimates CO using arterial pressure waveform analysis without external calibration. In this study, we compared CO obtained with a PAC using automatic thermodilution, instantaneous CO stat-mode (ICO(SM)), and CO obtained with the new device, arterial pressure waveform analysis (APCO) in patients undergoing liver transplantation. METHODS: Twenty sets of simultaneous measurements of APCO and ICO(SM) were determined in sedated and mechanically ventilated patients undergoing liver transplantation. Time points were as follows: after PAC insertion (T1-3), after portal clamping (T4-6), during anhepathy (T7-9), after graft reperfusion (T10-15), and in the postoperative period in the intensive care unit (T15-20). RESULTS: We enrolled 20 patients and 400 measurements were obtained. No data were rejected. Bias between ICO(SM) and APCO was 0.8 L/min, 95% limits of agreement were -1.8 to 3.5 L/min. The percentage error was 43%. Bias between ICO(SM) and APCO was correlated with systemic vascular resistance [r(2) = 0.55, P < 0.0001, y = 15.8-2.2 ln(x)] and subgroup analysis revealed an increase in the bias and in the percentage error in patients with low systemic vascular resistance (Child-Pugh grade B and C patients). There was no difference between the different surgical periods. CONCLUSIONS: Our results suggest that Vigileo/FloTrac CO monitoring data do not agree well with those of automatic thermodilution in patients undergoing liver transplantation, especially in Child-Pugh grade B and C patients with low systemic vascular resistance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e318168b309

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 187

Metadata

Authors
Matthieu, B., Karine, N.-G., Vincent, C., Alain, V., François, C. J., Philippe, R., & François, S.
Venue
Anesthesia & Analgesia
Published
2008-05
Volume
106
Issue
5
Pages
1480-1486
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2019039354
Cited by
187
References
3
FWCI
23.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Output Measurement in Patients Undergoing Liver Transplantation: Pulmonary Artery Catheter Versus Uncalibrated Arterial Pressure Waveform Analysis. https://app.cochat.ai/papers/10.1213/ane.0b013e318168b309
The paper
Matthieu, B., Karine, N.-G., Vincent, C., Alain, V., François, C. J., Philippe, R., & François, S. (2008). Cardiac Output Measurement in Patients Undergoing Liver Transplantation: Pulmonary Artery Catheter Versus Uncalibrated Arterial Pressure Waveform Analysis. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e318168b309

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.