CoChat

Point-of-Care Electronic Prompts: An Effective Means of Increasing Compliance, Demonstrating Quality, and Improving Outcome

Schwann, Nanette M., Bretz, Karen A., Eid, Sherrine, Burger, Terry, Fry, Deborah, Ackler, Frederick, Evans, Paul, Romancheck, David, Beck, Michelle, Ardire, Anthony J., Lukens, Harry, McLoughlin, Thomas M. · 2011 · Anesthesia & Analgesia
Cited by 51

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Incentives based on quality indicators such as the Surgical Care Improvement Project core measures (SCIP 1) encourage implementation of evidence-based guidelines consistently into clinical practice. Information systems with point-of-care electronic prompts (POCEPs) can facilitate adoption of processes and benchmark performance. We evaluated the effectiveness of POCEPs on rates of antibiotic administration within 60 minutes of surgical incision and effect on outcome in a prospective observational trial. METHODS: SCIP 1 compliance and the corresponding outcome variable (surgical site infection [SSI]) were examined prospectively over 2 consecutive 6-month periods before (A) and after (B) POCEPs implementation at a regional health system. Secondary analysis extended the observation to two 12-month periods (A' and B'). A 2-year (C and D) sustainability phase followed. RESULTS: The 19,744 procedures included 9127 and 10,617 procedures before (A) and after (B) POCEPs implementation, respectively. POCEPs increased compliance with SCIP indicators in period B by 31% (95% CI, 30.0%-32.2%) from 62% to 92% (P < 0.001) and were associated with a sustainable, contemporaneous decrease in the incidence of SSI from 1.1% to 0.7% (P = 0.003; absolute risk reduction, 0.4%; 95% CI, 0.1%-0.7%). Secondary and sustainability analysis revealed that compliance rates remained >95% with mean SSI rates lower for all periods compared with pre-POCEPs SSI rates (0.8%, 0.7%, and 0.5% vs 1.1%; P < 0.001). CONCLUSIONS: POCEPs increased compliance with SCIP indicators by >30% and were associated with a 0.4% absolute risk reduction in the incidence of SSI. POCEPs may be useful to modulate provider behavior and demonstrate intraoperative quality and value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e318227b511

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Use of Electronic Health Records in U.S. Hospitals

    Jha, A. K., DesRoches, C. M., Campbell, E. G., Donelan, K., Rao, S. R., Ferris, T. G., Shields, A., Rosenbaum, S., & Blumenthal, D. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0900592 · Cited by 1,473 · cited 1×

    “Investment in AIMS can be substantial, ranging from $250,000 to $2 million, commensurate with scale and complexity of the system.(33) Demonstrating a return on investment in tangible dollars directly arising from the implementation of AIMS (via the creation of efficiencies or decreased cost of reporting, etc) has been…”
    Background
  • Overrides of Medication Alerts in Ambulatory Care

    Isaac, T., Weissman, J. S., Davis, R. B., Massagli, M., Cyrulik, A., Sands, D. Z., & Weingart, S. N. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2008.551 · Cited by 309

Cited by

See all 51

Metadata

Authors
Schwann, N. M., Bretz, K. A., Eid, S., Burger, T., Fry, D., Ackler, F., Evans, P., Romancheck, D., Beck, M., Ardire, A. J., Lukens, H., & McLoughlin, T. M.
Venue
Anesthesia & Analgesia
Published
2011-10
Volume
113
Issue
4
Pages
869-876
ISSN
0003-2999 (ISSN-L)
OpenAlex
W1523445967
Cited by
51
References
2
FWCI
4.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.