BACKGROUND: The pulmonary artery catheter (PAC) continues to be used for monitoring of hemodynamics in patients undergoing coronary artery bypass graft (CABG) surgery despite concerns raised in other settings regarding both effectiveness and safety. Given the relative paucity of data regarding its use in CABG patients, and given entrenched practice patterns, we assessed the impact of PAC use on fatal and nonfatal CABG outcomes as practiced at a diverse set of medical centers. METHODS: Using a formal prospective observational study design, 5065 CABG patients from 70 centers were enrolled between November 1996 and June 2000 using a systemic sampling protocol. Propensity score matched-pair analysis was used to adjust for differences in likelihood of PAC insertion. The predefined composite endpoint was the occurrence of any of the following: death (any cause), cardiac dysfunction (myocardial infarction or congestive heart failure), cerebral dysfunction (stroke or encephalopathy), renal dysfunction (dysfunction or failure), or pulmonary dysfunction (acute respiratory distress syndrome). Secondary variables included treatment indices (inotrope use, fluid administration), duration of postoperative intubation, and intensive care unit length of stay. After categorization based on PAC and transesophageal echocardiography use (both, neither, PAC only, transesophageal echocardiography only), we performed the primary analysis contrasting PAC only and neither (total, 3321 patients), from which propensity paring yielded 1273 matched pairs. RESULTS: The primary endpoint occurred in 271 PAC patients versus 196 without PAC (21.3% vs.15.4%; adjusted odds ratio [AOR], 1.68; 95% confidence interval [CI], 1.24 to 2.26; P<0.001). The PAC group had an increased risk of all-cause mortality, 3.5% vs 1.7% (AOR, 2.08; 95% CI, 1.11 to 3.88; P=0.02) and an increased risk of cardiac (AOR, 1.58; 95% CI, 1.14 to 2.20; P=0.007), cerebral (AOR, 2.02; 95% CI, 1.08 to 3.77; P=0.03) and renal (AOR, 2.47; 95% CI, 1.68 to 3.62; P<0.001) morbid outcomes. PAC patients received inotropic drugs more frequently (57.8% vs 50.0%; P<0.001), had a larger positive IV fluid balance after surgery (3220 mL vs 3022 mL; P=0.003), and experienced longer time to tracheal extubation (15.40 hours [11.28/20.80] versus 13.18 hours [9.58/19.33], median plus Q1/Q3 interquartile range; P<0.0001). Use of PAC was also associated with prolonged intensive care unit stay (14.5% vs 10.1%; AOR, 1.55; 95% CI, 1.06 to 2.27; P=0.02). CONCLUSIONS: Use of a PAC during CABG surgery was associated with increased mortality and a higher risk of severe end-organ complications in this propensity-matched observational study. A randomized controlled trial with defined hemodynamic goals would be ideal to either confirm or refute our findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e31822c94a8

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 147

Metadata

Authors
Schwann, N. M., Hillel, Z., Hoeft, A., Barash, P., Möhnle, P., Miao, Y., & Mangano, D. T.
Venue
Anesthesia & Analgesia
Published
2011-11
Volume
113
Issue
5
Pages
994-1002
ISSN
0003-2999 (ISSN-L)
OpenAlex
W407205323
Cited by
147
References
4
FWCI
13.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lack of Effectiveness of the Pulmonary Artery Catheter in Cardiac Surgery. https://app.cochat.ai/papers/10.1213/ane.0b013e31822c94a8
The paper
Schwann, N. M., Hillel, Z., Hoeft, A., Barash, P., Möhnle, P., Miao, Y., & Mangano, D. T. (2011). Lack of Effectiveness of the Pulmonary Artery Catheter in Cardiac Surgery. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e31822c94a8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.