CoChat

Oxygen Desaturation Index from Nocturnal Oximetry: A Sensitive and Specific Tool to Detect Sleep-Disordered Breathing in Surgical Patients

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: It is impractical to perform polysomnography (PSG) in all surgical patients suspected of having sleep disordered breathing (SDB). We investigated the role of nocturnal oximetry in diagnosing SDB in surgical patients. METHOD: All patients 18 years and older who visited the preoperative clinics for scheduled inpatient surgery were approached for study participation. Patients expected to have abnormal electroencephalographic findings were excluded. All patients underwent an overnight PSG at home with a portable device and a pulse oximeter. The PSG recordings were scored by a certified sleep technologist. The oximetry recordings were processed electronically. RESULT: Four hundred seventy-five patients completed the study: 217 males and 258 females, aged 60 ± 11 years, and body mass index 31 ± 7 kg/m(2). The apnea-hypopnea index (AHI), the average number of episodes of apnea and hypopnea per hour of sleep, was 9.1 (2.8 to 21.4) [median (interquartile range)] and 64% patients had AHI >5. There was a significant correlation between oxygen desaturation index (ODI, hourly average number of desaturation episodes) and cumulative time percentage with SpO(2) <90% (CT90) from nocturnal oximetry, with the parameters measuring sleep breathing disorders from PSG. Compared to CT90, ODI had a stronger correlation and was a better predictor for AHI. The area under receiver operator characteristics curve for ODI to predict AHI >5, AHI >15, and AHI >30 was 0.908 (CI: 0.880 to 0.936), 0.931 (CI: 0.090 to 0.952), and 0.958 (CI: 0.937 to 0.979), respectively. The cutoff value based on the maximal accuracy for ODI to predict AHI >5, AHI >15, and AHI >30 was ODI >5, ODI >15, and ODI >30. The accuracy was 86% (CI: 83%-88%), 86% (CI: 83%-89%), and 94% (CI: 92%-96%), respectively. The ODI >10 demonstrated a sensitivity of 93% and a specificity of 75% to detect moderate and severe SDB. CONCLUSIONS: ODI from a high-resolution nocturnal oximeter is a sensitive and specific tool to detect undiagnosed SDB in surgical patients.

Overview

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e318248f4f5

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 38 references

Research works printed but not linked: 2

  1. 1997, Polysomnography Task Force, Am Sleep Disorders Association Standards of Practice Committee., Sleep, 20, 406
  2. 1994, Standards of Practice Committee of the Am Sleep Disorders Association., Sleep, 17, 372

Cited by

See all 243

Metadata

Authors
Chung, F., Liao, P., Elsaid, H., Islam, S., Shapiro, C. M., & Sun, Y.
Affiliations
University Health Network (CA)
Corresponding author
  • Chung, Frances
  • Liao, Pu
  • Elsaid, Hisham
  • Islam, Sazzadul
  • Sun, Yuming
Venue
Anesthesia & Analgesia
Published
2012-05
Volume
114
Issue
5
Pages
993-1000
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2071545991
Cited by
243
References
38
Citations by year
2026: 5 · 2025: 11 · 2024: 17 · 2023: 18 · 2022: 25 · 2021: 22 · 2020: 25 · 2019: 26 · 2018: 23 · 2017: 16 · 2016: 14 · 2015: 14 · 2014: 13 · 2013: 11 · 2012: 3
FWCI
8.79
Type
journal article
Language
en
Open access
closed
Locations
  • Anesthesia & Analgesia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
Keywords
oxygen desaturation index, nocturnal oximetry, sleep-disordered breathing, apnea-hypopnea index, preoperative screening, surgical patients, home sleep testing, pulse oximetry, diagnostic accuracy, obesity, obstructive sleep apnea, cost-effectiveness
MeSH terms
Aged, Arousal, Data Interpretation, Statistical, Electroencephalography, Female, Humans, Male, Middle Aged, Oximetry, Oxygen Consumption, ROC Curve, Sleep Apnea Syndromes, Sleep Stages, Body Mass Index, Polysomnography, Sample Size, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oxygen Desaturation Index from Nocturnal Oximetry: A Sensitive and Specific Tool to Detect Sleep-Disordered Breathing in Surgical Patients. https://app.cochat.ai/papers/10.1213/ane.0b013e318248f4f5
The paper
Chung, F., Liao, P., Elsaid, H., Islam, S., Shapiro, C. M., & Sun, Y. (2012). Oxygen Desaturation Index from Nocturnal Oximetry: A Sensitive and Specific Tool to Detect Sleep-Disordered Breathing in Surgical Patients. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e318248f4f5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.