Oxygen Desaturation Index from Nocturnal Oximetry: A Sensitive and Specific Tool to Detect Sleep-Disordered Breathing in Surgical Patients
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: It is impractical to perform polysomnography (PSG) in all surgical patients suspected of having sleep disordered breathing (SDB). We investigated the role of nocturnal oximetry in diagnosing SDB in surgical patients. METHOD: All patients 18 years and older who visited the preoperative clinics for scheduled inpatient surgery were approached for study participation. Patients expected to have abnormal electroencephalographic findings were excluded. All patients underwent an overnight PSG at home with a portable device and a pulse oximeter. The PSG recordings were scored by a certified sleep technologist. The oximetry recordings were processed electronically. RESULT: Four hundred seventy-five patients completed the study: 217 males and 258 females, aged 60 ± 11 years, and body mass index 31 ± 7 kg/m(2). The apnea-hypopnea index (AHI), the average number of episodes of apnea and hypopnea per hour of sleep, was 9.1 (2.8 to 21.4) [median (interquartile range)] and 64% patients had AHI >5. There was a significant correlation between oxygen desaturation index (ODI, hourly average number of desaturation episodes) and cumulative time percentage with SpO(2) <90% (CT90) from nocturnal oximetry, with the parameters measuring sleep breathing disorders from PSG. Compared to CT90, ODI had a stronger correlation and was a better predictor for AHI. The area under receiver operator characteristics curve for ODI to predict AHI >5, AHI >15, and AHI >30 was 0.908 (CI: 0.880 to 0.936), 0.931 (CI: 0.090 to 0.952), and 0.958 (CI: 0.937 to 0.979), respectively. The cutoff value based on the maximal accuracy for ODI to predict AHI >5, AHI >15, and AHI >30 was ODI >5, ODI >15, and ODI >30. The accuracy was 86% (CI: 83%-88%), 86% (CI: 83%-89%), and 94% (CI: 92%-96%), respectively. The ODI >10 demonstrated a sensitivity of 93% and a specificity of 75% to detect moderate and severe SDB. CONCLUSIONS: ODI from a high-resolution nocturnal oximeter is a sensitive and specific tool to detect undiagnosed SDB in surgical patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Using overnight oximetry has been found to have a very good correlation with AHI on PSG in surgical patients.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [499]
In the citing paper
“In the general population, two Level 1b studies,499,616 three Level 2b studies,617–619 and one Level 3b620 found reasonably good correlations between oximetry ODI and PSG AHIs, though primarily when the 4% desaturation criteria was used to score respiratory events.”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [499]
In the citing paper
“Using a cutoff of AHI ≥ 5, accuracy was 73% (95% CI: 68 to 78%) in a high-risk population, and 79% (95% CI: 74 to 84%) in a low-risk population.”
From Clinical Practice Guideline for Diagnostic Testing for Adult Obstructive Sleep Apnea: An American Academy of Sleep Medicine Clinical Practice Guideline (2017) · cites this paper as [111]
In the citing paper
“A single study evaluated the performance of oximetry against unattended in-home PSG.”
From Clinical Practice Guideline for Diagnostic Testing for Adult Obstructive Sleep Apnea: An American Academy of Sleep Medicine Clinical Practice Guideline (2017) · cites this paper as [111]
In the citing paper
“Using oximetry to identify OSA at an AHI ≥ 5 cutoff, and assuming a prevalence of 87% in a high-risk population, the findings of the study111 would result in an estimated average of 274 misdiagnosed patients out of 1,000 tested, and 210 misdiagnosed patients out of 1,000 tested in a low-risk group (assuming a prevalence of 55%).”
From Clinical Practice Guideline for Diagnostic Testing for Adult Obstructive Sleep Apnea: An American Academy of Sleep Medicine Clinical Practice Guideline (2017) · cites this paper as [111]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
(2007) · Cited by 6,530
Epidemiology of Obstructive Sleep Apnea: A Population Health Perspective
Young, T., Peppard, P. E., & Gottlieb, D. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109080 · Cited by 4,244 · cited 1×
“7% of women with AHI 15 as the OSA diagnostic criteria.(9) It is estimated that nearly 80% of men and 93% of women with moderate to severe sleep apnea are undiagnosed.”
BackgroundSleep Disordered Breathing and Mortality: Eighteen-Year Follow-up of the Wisconsin Sleep Cohort
(2008) · Sleep · doi:10.5665/sleep/31.8.1071 · Cited by 1,853
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Perioperative safety in the longitudinal assessment of bariatric surgery
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901836 · Cited by 1,392
Collop, N. A., Anderson, W. M., Boehlecke, B. A., Claman, D. M., Goldberg, R., Gottlieb, D. J., Hudgel, D. W., Sateia, M. J., & Schwab, R. (2007) · PubMed Central · Cited by 1,082
Association of sleep apnoea with myocardial infarction in men
Hung, J., Whitford, E. G., Hillman, D. R., & Parsons, R. W. (1990) · The Lancet · doi:10.1016/0140-6736(90)91799-g · Cited by 907
Sleep Apnea and Cardiovascular Disease
LEUNG, R. S. T., & DOUGLAS BRADLEY, T. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.12.2107045 · Cited by 649
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d91b5 · Cited by 571
Self-citationDoherty, L. S., Kiely, J. L., Swan, V., & McNicholas, W. T. (2005) · Chest · doi:10.1378/chest.127.6.2076 · Cited by 485
Increasing Sleep Duration for a Healthier (and Less Obese?) Population Tomorrow
Young, T. (2008) · Sleep · doi:10.1093/sleep/31.5.593 · Cited by 327
A Systemic Review of Obstructive Sleep Apnea and Its Implications for Anesthesiologists
Chung, S. A., Yuan, H., & Chung, F. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318187c83a · Cited by 326 · cited 1×
“patient’s possible difficult airway, increased sensitivity to narcotics, and postoperative upper airway obstruction.(5) It”
BackgroundSelf-citationLiao, P., Yegneswaran, B., Vairavanathan, S., Zilberman, P., & Chung, F. (2009) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-009-9190-y · Cited by 316
Self-citationOvernight Pulse Oximetry for Sleep-Disordered Breathing in Adults
Netzer, N., Eliasson, A. H., Netzer, C., & Kristo, D. A. (2001) · Chest · doi:10.1378/chest.120.2.625 · Cited by 311 · cited 1×
“have suggested that patients with strong clinical suspicion for SDB and ODI 15 on oximetry should have autocontinuous positive airway pressure titration at home.(22) Although using nocturnal oximetry to detect patients with SDB is not a new idea, there are methodological issues in previously published studies.”
BackgroundPrevalence of Symptoms and Risk of Sleep Apnea in Primary Care
Netzer, N. C., Hoegel, J. J., Loube, D., Netzer, C. M., Hay, B., Alvarez-Sala, R., & Strohl, K. P. (2003) · Chest · doi:10.1378/chest.124.4.1406 · Cited by 273 · cited 8×
“Several studies used PSG on a different night to evaluate the predictive performance of the oximeter.13,24,26 Because of the environmental difference between home and sleep laboratory, and night-to-night variability in the frequency of sleep apnea and hypopnea,27,28 PSG not performed on the same night as oximetry may…”
MethodInfluentialAutomated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea
Vazquez, J.-C. (2000) · Thorax · doi:10.1136/thorax.55.4.302 · Cited by 254 · cited 1×
“Two previous studies used off-line analysis of pulse oximetry data from PSG as the oximetry data against the PSG data to evaluate the predictive performance of oximetry.(23,29) Because sampling frequency of the oximeter on PSG is usually higher than that of a stand-alone oximeter, and the same pulse oximetry data were…”
Sample size calculations in studies of test accuracy
Obuchowski, N. A. (1998) · Statistical Methods in Medical Research · doi:10.1177/096228029800700405 · Cited by 221 · cited 2×
“The calculation of sample size was performed according to the method reported by Obuchowski.17 The sample size was calculated based on the sensitivity and specificity of ODI 10 for the prediction of AHI 5 from a previous study of patients suspected of having OSA18 and prevalence of OSA.19,20 When a sensitivity of 0.82…”
MethodInfluentialHomogeneity of Variance in the Two-Sample Means Test
Moser, B. K., & Stevens, G. R. (1992) · The American Statistician · doi:10.1080/00031305.1992.10475839 · Cited by 220
Series, F., Marc, I., Cormier, Y., & La Forge, J. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-119-6-199309150-00001 · Cited by 196 · cited 1×
“Several studies used PSG on a different night to evaluate the predictive performance of the oximeter.(13,24,26) Because of the environmental difference between home and sleep laboratory, and night-to-night variability in the frequency of sleep apnea and hypopnea,(27,28) PSG not performed on the same night as oximetry…”
MethodPrediction of the Apnea-Hypopnea Index From Overnight Pulse Oximetry *
Magalang, U. J., Dmochowski, J., Veeramachaneni, S., Draw, A., Mador, M. J., El-Solh, A., & Grant, B. J. B. (2003) · Chest · doi:10.1378/chest.124.5.1694 · Cited by 189 · cited 4×
“Two previous studies used off-line analysis of pulse oximetry data from PSG as the oximetry data against the PSG data to evaluate the predictive performance of oximetry.(23,29) Because sampling frequency of the oximeter on PSG is usually higher than that of a stand-alone oximeter, and the same pulse oximetry data were…”
BackgroundInfluentialAccuracy of Oximetry for Detection of Respiratory Disturbances in Sleep Apnea Syndrome
Lévy, P., Louis Pépin, J., Deschaux-Blanc, C., Paramelle, B., & Brambilla, C. (1996) · Chest · doi:10.1378/chest.109.2.395 · Cited by 188
The variability of the apnoea–hypopnoea index
Bittencourt, L. R. A., Suchecki, D., Tufik, S., Peres, C., Togeiro, S. M., Bagnato, M. D. C., & Nery, L. E. (2001) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2001.00255.x · Cited by 160
Chiner, E., Signes-Costa, J., Arriero, J. M., Marco, J., Fuentes, I., & Sergado, A. (1999) · Thorax · doi:10.1136/thx.54.11.968 · Cited by 157
Screening for Sleep Apnea Using Pulse Oximetry and A Clinical Score
Williams, A. J., Yu, G. W., Santiago, S., & Stein, M. (1991) · CHEST Journal · doi:10.1378/chest.100.3.631 · Cited by 155 · cited 1×
“Several studies used PSG on a different night to evaluate the predictive performance of the oximeter.(13,24,26) Because of the environmental difference between home and sleep laboratory, and night-to-night variability in the frequency of sleep apnea and hypopnea,(27,28) PSG not performed on the same night as oximetry…”
MethodThorpy, M. J., Chesson, A. L., Ferber, R. A., Kader, G. A.-E., Millman, R. P., Reite, M. L., Smith, P. L., & Wooten, V. D. (1994) · SLEEP · Cited by 138
Álvarez, D., Hornero, R., García, M., del Campo, F., & Zamarrón, C. (2007) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2007.06.002 · Cited by 86
Marcos, J. V., Hornero, R., Álvarez, D., del Campo, F., & Zamarrón, C. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.05.010 · Cited by 81
Prediction of sleep‐disordered breathing by unattended overnight oximetry
OLSON, L. G., AMBROGETTI, A., & GYULAY, S. G. (1999) · Journal of Sleep Research · doi:10.1046/j.1365-2869.1999.00134.x · Cited by 76 · cited 4×
“This may also affect the positive and negative predictive value of the ODI and CT90.”
ResultInfluentialSymptom-Based Prevalence of Sleep Disorders in an Adult Primary Care Population
Kushida, C. A., Nichols, D. A., Simon, R., Young, T. B., Grauke, J. H., Britzmann, J. B., Hyde, P. R., & Dement, W. C. (2000) · Sleep And Breathing · doi:10.1007/s11325-000-0011-3 · Cited by 48 · cited 8×
“Several studies used PSG on a different night to evaluate the predictive performance of the oximeter.13,24,26 Because of the environmental difference between home and sleep laboratory, and night-to-night variability in the frequency of sleep apnea and hypopnea,27,28 PSG not performed on the same night as oximetry may…”
MethodInfluentialLin, C.-L., Yeh, C., Yen, C., Hsu, W., & Hang, L. (2008) · CHEST Journal · doi:10.1378/chest.08-0057 · Cited by 48 · cited 4×
“This may also affect the positive and negative predictive value of the ODI and CT90.”
ResultInfluentialPerioperative practical experiences in using a level 2 portable polysomnography
Chung, F. F., Liao, P., Sun, Y., Amirshahi, B., Fazel, H., Shapiro, C. M., & Elsaid, H. (2010) · Sleep And Breathing · doi:10.1007/s11325-010-0340-9 · Cited by 44 · cited 2×
“Embletta 100 is a level 2 diagnostic tool for OSA(14) and has been validated against laboratory PSG.(15) The PSG recording montage consisted of 2 EEG channels (C3 and C4), left or right electroculogram, chin muscle electromyogram, nasal cannula (pressure), thoracic and abdominal respiratory effort bands, body-position…”
MethodSelf-citationSymptom-Based Prevalence of Sleep Disorders in an Adult Primary Care Population
Kushida, C. A., Nichols, D. A., Simon, R., Young, T. B., Grauke, J. H., Britzmann, J. B., Hyde, P. R., & Dement, W. C. (2000) · Sleep And Breathing · doi:10.1055/s-2000-11530 · Cited by 40
Effect of body mass index on overnight oximetry for the diagnosis of sleep apnea
Nakano, H., Ikeda, T., Hayashi, M., Ohshima, E., Itoh, M., Nishikata, N., & Shinohara, T. (2004) · Respiratory Medicine · doi:10.1016/j.rmed.2003.11.009 · Cited by 38
Teramoto, S., Matsuse, T., & Fukuchi, Y. (2002) · Sleep Medicine · doi:10.1016/s1389-9457(01)00129-0 · Cited by 20 · cited 1×
“Several studies used PSG on a different night to evaluate the predictive performance of the oximeter.(13,24,26) Because of the environmental difference between home and sleep laboratory, and night-to-night variability in the frequency of sleep apnea and hypopnea,(27,28) PSG not performed on the same night as oximetry…”
MethodÁlvarez, D., Hornero, R., Abásolo, D., del Campo, F., Zamarrón, C., & López, M. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/9/008 · Cited by 18
Martinez, M. W., Rodysill, K. J., & Morgenthaler, T. I. (2005) · Mayo Clinic Proceedings · doi:10.4065/80.4.455 · Cited by 17
Lack of night-to-night variability of sleep-disordered breathing measured during home monitoring
Davidson, T. M., Gehrman, P., & Ferreyra, H. A. (2003) · Ear Nose & Throat Journal · doi:10.1177/014556130308200215 · Cited by 9
Research works printed but not linked: 2
- 1997, Polysomnography Task Force, Am Sleep Disorders Association Standards of Practice Committee., Sleep, 20, 406
- 1994, Standards of Practice Committee of the Am Sleep Disorders Association., Sleep, 17, 372
Cited by
Kapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Party:, M. O. T. W., Nightingale, C. E., Margarson, M. P., Shearer, E., Redman, J. W., Lucas, D. N., Cousins, J. M., Fox, W. T. A., Kennedy, N. J., Venn, P. J., et al. (2015) · Anaesthesia · doi:10.1111/anae.13101 · Cited by 341
Chan, M. T. V., Wang, C. Y., Seet, E., Tam, S., Lai, H. Y., Chew, E. F. F., Wu, W. K. K., Cheng, B. C. P., Lam, C. K. M., Short, T. G., et al. (2019) · JAMA · doi:10.1001/jama.2019.4783 · Cited by 277
“Results, median (IQR) Respiratory event index, events/hf 40 (35-52) 20 (17-24) 8 (6-10) 2 (1-3) <.”
Self-citationPerioperative management of obstructive sleep apnea in bariatric surgery: a consensus guideline
de Raaff, C. A. L., Gorter-Stam, M., de Vries, N., Sinha, A. C., Bonjer, H. J., Chung, F. F., Coblijn, U. K., Dahan, A., van den Helder, R. S., Hilgevoord, A. A. J., et al. (2017) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2017.03.022 · Cited by 164
Self-citation
Metadata
- Authors
- Chung, F., Liao, P., Elsaid, H., Islam, S., Shapiro, C. M., & Sun, Y.
- Affiliations
- University Health Network (CA)
- Corresponding author
- Chung, Frances
- Liao, Pu
- Elsaid, Hisham
- Islam, Sazzadul
- Sun, Yuming
- Venue
- Anesthesia & Analgesia
- Published
- 2012-05
- Volume
- 114
- Issue
- 5
- Pages
- 993-1000
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2071545991
- Semantic Scholar
- a1e7de52b72668f3b8cfe12361aa027ec3465006
- Cited by
- 243
- References
- 38
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 17 · 2023: 18 · 2022: 25 · 2021: 22 · 2020: 25 · 2019: 26 · 2018: 23 · 2017: 16 · 2016: 14 · 2015: 14 · 2014: 13 · 2013: 11 · 2012: 3
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Anesthesia & Analgesia (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
- Keywords
- oxygen desaturation index, nocturnal oximetry, sleep-disordered breathing, apnea-hypopnea index, preoperative screening, surgical patients, home sleep testing, pulse oximetry, diagnostic accuracy, obesity, obstructive sleep apnea, cost-effectiveness
- MeSH terms
- Aged, Arousal, Data Interpretation, Statistical, Electroencephalography, Female, Humans, Male, Middle Aged, Oximetry, Oxygen Consumption, ROC Curve, Sleep Apnea Syndromes, Sleep Stages, Body Mass Index, Polysomnography, Sample Size, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.