CoChat

Toward Optimal Tissue Sealants for Neurosurgery: Use of a Novel Hydrogel Sealant in a Canine Durotomy Repair Model

Preul, Mark C., Bichard, William D., Muench, Timothy R., Spetzler, Robert F. · 2003 · Neurosurgery
Cited by 102

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Watertight dural repairs are difficult to achieve, and cerebrospinal fluid leakage causes complications and extends hospital stays. Therefore, a novel synthetic hydrogel film was evaluated as an adjunct to dural closure in a canine model. METHODS: The self-polymerizing, absorbable, and biocompatible hydrogel was sprayed onto tissue and formed a flexible, adherent sealant. A 2-cm incision of cranial dura and arachnoid was created in 26 adult dogs and loosely repaired. Hydrogel was applied over the 2-mm dural gap in 13 dogs; 13 control dogs received no hydrogel application. RESULTS: All dogs remained neurologically intact. Valsalva tests conducted at 1, 4, 7, and 56 days were associated with mean leakage pressures (+/- standard error of the mean) of 5 +/- 0, 5 +/- 0, 7 +/- 2, and 13 +/- 8 cm H(2)O in the controls and of 53 +/- 2, 37 +/- 11, 42 +/- 6, and 48 +/- 4 in the treated animals (P = 0.001, 0.053, 0.010, 0.035, respectively, at each time point; one-tailed t test). Histopathological analysis revealed minimal changes. CONCLUSION: The hydrogel-treated animals exhibited normal progression of dural healing, no dural adhesions, and no underlying effects on the brain. Although dural healing progressed normally, the control animals displayed marked peridural adhesions. The results of this in vivo study suggest that hydrogels, such as that used here, may significantly decrease cerebrospinal fluid leakage, thereby increasing the safety and effectiveness of dural closure in patients and facilitating surgical reexploration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000089481.87226.f7

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 102

Metadata

Authors
Preul, M. C., Bichard, W. D., Muench, T. R., & Spetzler, R. F.
Venue
Neurosurgery
Published
2003-11
Volume
53
Issue
5
Pages
1189-1199
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2126113774
Cited by
102
References
0
FWCI
0.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Toward Optimal Tissue Sealants for Neurosurgery: Use of a Novel Hydrogel Sealant in a Canine Durotomy Repair Model. https://app.cochat.ai/papers/10.1227/01.neu.0000089481.87226.f7
The paper
Preul, M. C., Bichard, W. D., Muench, T. R., & Spetzler, R. F. (2003). Toward Optimal Tissue Sealants for Neurosurgery: Use of a Novel Hydrogel Sealant in a Canine Durotomy Repair Model. Neurosurgery. https://doi.org/10.1227/01.neu.0000089481.87226.f7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.