The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Endovascular Coil Occlusion of 1811 Intracranial Aneurysms: Early Angiographic and Clinical Results
Abstract
OBJECTIVE: We sought to evaluate the early angiographic and clinical outcomes of the first session of endovascular coil occlusion of a large number of patients with intracranial aneurysms treated by five neurointerventionalists during a decade at a single center. METHODS: We performed retrospective analyses of pre- and postprocedural angiographic studies and early clinical outcomes. Enrolled patients underwent endovascular treatment of intracranial aneurysms with detachable coils. RESULTS: A total of 1811 aneurysms in 1579 patients were treated with coil occlusion. Of these, 90 to 100% occlusion of 86.5% of the aneurysms was achieved. In 82.3% of the procedures, no complications occurred. The clinical outcome profile at primary discharge according to the Glasgow Outcome Scale was as follows: Grade V, 74.6%; Grade IV, 6.7%; Grade III, 11.1%; Grade II, 3.1%; and Grade I, 4.5%. In patients with large aneurysms with wide necks, a lower occlusion rate and an increased complication rate were encountered. The use of three-dimensional and fibered coils resulted in higher occlusion rates. Balloon remodeling and stent deployment increased the complication rate. Previous aneurysm rupture, procedural complications, and vasospasm correlated with poor outcome. Of the patients in poor grade after aneurysm rupture, 42% recovered to Glasgow Outcome Scale Grade IV or V, as opposed to 90% of patients who were treated for unruptured aneurysms. The ischemic complication rate was 9%, and the hemorrhagic complication rate was 3%. The early procedural morbidity rate was 5.3%, and the procedural mortality rate was 1.5%. The management mortality rate was 4.4%. CONCLUSION: These data confirm the safety and efficacy of endovascular coil occlusion for patients with intracranial aneurysms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ASSESSMENT OF OUTCOME AFTER SEVERE BRAIN DAMAGE A Practical Scale
JENNETT, B. (1975) · The Lancet · doi:10.1016/s0140-6736(75)92830-5 · Cited by 7,501
Surgical Risk as Related to Time of Intervention in the Repair of Intracranial Aneurysms
Hunt, W. E., & Hess, R. M. (1968) · CRC Press eBooks · doi:10.1201/9781003416197-10 · Cited by 3,371
Fisher, C. M., Kistler, J. P., & Davis, J. M. (1980) · Neurosurgery · doi:10.1227/00006123-198001000-00001 · Cited by 3,080
(1964) · The Lancet · doi:10.1016/s0140-6736(64)90810-4 · Cited by 2,898
Guglielmi, G., Viñuela, F., Sepetka, I., & Macellari, V. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.75.1.0001 · Cited by 1,260
Treatment of Intracranial Aneurysms by Embolization with Coils: A Systematic Review
Brilstra, E. H., Rinkel, G. J. E., van der Graaf, Y., van Rooij, W. J. J., & Algra, A. (1999) · Stroke · doi:10.1161/01.str.30.2.470 · Cited by 491
Byrne, J. V., Sohn, M.-J., & Molyneux, A. J. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.4.0656 · Cited by 485
Bederson, J. B., Awad, I. A., Wiebers, D. O., Piepgras, D., Haley, E. C., Brott, T., Hademenos, G., Chyatte, D., Rosenwasser, R., & Caroselli, C. (2000) · Stroke · doi:10.1161/01.str.31.11.2742 · Cited by 419
Long-term Angiographic Follow-up of 169 Intracranial Berry Aneurysms Occluded with Detachable Coils
Cognard, C., Weill, A., Spelle, L., Piotin, M., Castaings, L., Rey, A., & Moret, J. (1999) · Radiology · doi:10.1148/radiology.212.2.r99jl47348 · Cited by 413
Cited by
Small, W., Buckley, P. R., Wilson, T. S., Benett, W. J., Hartman, J., Saloner, D., & Maitland, D. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889771 · Cited by 124
Metadata
- Authors
- Henkes, H., Fischer, S., Weber, W., Miloslavski, E., Felber, S., Brew, S., & Kuehne, D.
- Venue
- Neurosurgery
- Published
- 2004-02-01
- Volume
- 54
- Issue
- 2
- Pages
- 268-285
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W1983924397
- Cited by
- 322
- References
- 36
- FWCI
- 15.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endovascular Coil Occlusion of 1811 Intracranial Aneurysms: Early Angiographic and Clinical Results. https://app.cochat.ai/papers/10.1227/01.neu.0000103221.16671.f0
- The paper
- Henkes, H., Fischer, S., Weber, W., Miloslavski, E., Felber, S., Brew, S., & Kuehne, D. (2004). Endovascular Coil Occlusion of 1811 Intracranial Aneurysms: Early Angiographic and Clinical Results. Neurosurgery. https://doi.org/10.1227/01.neu.0000103221.16671.f0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.