Endovascular Coil Occlusion of 1811 Intracranial Aneurysms: Early Angiographic and Clinical Results
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We sought to evaluate the early angiographic and clinical outcomes of the first session of endovascular coil occlusion of a large number of patients with intracranial aneurysms treated by five neurointerventionalists during a decade at a single center. METHODS: We performed retrospective analyses of pre- and postprocedural angiographic studies and early clinical outcomes. Enrolled patients underwent endovascular treatment of intracranial aneurysms with detachable coils. RESULTS: A total of 1811 aneurysms in 1579 patients were treated with coil occlusion. Of these, 90 to 100% occlusion of 86.5% of the aneurysms was achieved. In 82.3% of the procedures, no complications occurred. The clinical outcome profile at primary discharge according to the Glasgow Outcome Scale was as follows: Grade V, 74.6%; Grade IV, 6.7%; Grade III, 11.1%; Grade II, 3.1%; and Grade I, 4.5%. In patients with large aneurysms with wide necks, a lower occlusion rate and an increased complication rate were encountered. The use of three-dimensional and fibered coils resulted in higher occlusion rates. Balloon remodeling and stent deployment increased the complication rate. Previous aneurysm rupture, procedural complications, and vasospasm correlated with poor outcome. Of the patients in poor grade after aneurysm rupture, 42% recovered to Glasgow Outcome Scale Grade IV or V, as opposed to 90% of patients who were treated for unruptured aneurysms. The ischemic complication rate was 9%, and the hemorrhagic complication rate was 3%. The early procedural morbidity rate was 5.3%, and the procedural mortality rate was 1.5%. The management mortality rate was 4.4%. CONCLUSION: These data confirm the safety and efficacy of endovascular coil occlusion for patients with intracranial aneurysms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ASSESSMENT OF OUTCOME AFTER SEVERE BRAIN DAMAGE A Practical Scale
JENNETT, B. (1975) · The Lancet · doi:10.1016/s0140-6736(75)92830-5 · Cited by 7,501
Surgical Risk as Related to Time of Intervention in the Repair of Intracranial Aneurysms
Hunt, W. E., & Hess, R. M. (1968) · CRC Press eBooks · doi:10.1201/9781003416197-10 · Cited by 3,371
Fisher, C. M., Kistler, J. P., & Davis, J. M. (1980) · Neurosurgery · doi:10.1227/00006123-198001000-00001 · Cited by 3,080
(1964) · The Lancet · doi:10.1016/s0140-6736(64)90810-4 · Cited by 2,898
Guglielmi, G., Viñuela, F., Sepetka, I., & Macellari, V. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.75.1.0001 · Cited by 1,260
Treatment of Intracranial Aneurysms by Embolization with Coils: A Systematic Review
Brilstra, E. H., Rinkel, G. J. E., van der Graaf, Y., van Rooij, W. J. J., & Algra, A. (1999) · Stroke · doi:10.1161/01.str.30.2.470 · Cited by 491
Byrne, J. V., Sohn, M.-J., & Molyneux, A. J. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.4.0656 · Cited by 485
Bederson, J. B., Awad, I. A., Wiebers, D. O., Piepgras, D., Haley, E. C., Brott, T., Hademenos, G., Chyatte, D., Rosenwasser, R., & Caroselli, C. (2000) · Stroke · doi:10.1161/01.str.31.11.2742 · Cited by 419
Long-term Angiographic Follow-up of 169 Intracranial Berry Aneurysms Occluded with Detachable Coils
Cognard, C., Weill, A., Spelle, L., Piotin, M., Castaings, L., Rey, A., & Moret, J. (1999) · Radiology · doi:10.1148/radiology.212.2.r99jl47348 · Cited by 413
Eskridge, J. M., Song, J. K., & _, _. (1998) · Journal of Neurosurgery · doi:10.3171/jns.1998.89.1.0081 · Cited by 291
Endovascular and surgical treatment of unruptured cerebral aneurysms: Comparison of risks
Johnston, S. C., Wilson, C. B., Halbach, V. V., Higashida, R. T., Dowd, C. F., McDermott, M. W., Applebury, C. B., Farley, T. L., & Gress, D. R. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200007)48:1<11::aid-ana4>3.0.co;2-v · Cited by 286
Qureshi, A. I., Luft, A. R., Sharma, M., Guterman, L. R., & Hopkins, L. N. (2000) · Neurosurgery · doi:10.1097/00006123-200006000-00014 · Cited by 253
Vanninen, R., Koivisto, T., Saari, T., Hernesniemi, J. A., & Vapalahti, M. P. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ap06325 · Cited by 236
Selective endovascular treatment of 71 intracranial aneurysms with platinum coils
Casasco, A. E., Aymard, A., Gobin, Y. P., Houdart, E., Rogopoulos, A., George, B., Hodes, J. E., Cophignon, J., & Merland, J. J. (1993) · Journal of Neurosurgery · doi:10.3171/jns.1993.79.1.0003 · Cited by 233
Kawanabe, Y., Sadato, A., Taki, W., & Hashimoto, N. (2001) · Acta Neurochirurgica · doi:10.1007/s007010170073 · Cited by 229
Embolization of incidental cerebral aneurysms by using the Guglielmi detachable coil system
Murayama, Y., Viñuela, F., Duckwiler, G. R., Gobin, Y. P., & Guglielmi, G. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.2.0207 · Cited by 227
Rordorf, G. A., Bellon, R. J., Budzik, R. F., Farkas, J., Reinking, G. F., Pergolizzi, R. S., Ezzeddine, M. A., Norbash, A., González, R., & Putman, C. M. (2001) · PubMed Central · Cited by 174
Ng, P., Khangure, M. S., Phatouros, C. C., Bynevelt, M., ApSimon, H., & McAuliffe, W. (2002) · Stroke · doi:10.1161/hs0102.100486 · Cited by 172
Regli, L., Uské, A., & de Tribolet, N. (1999) · Journal of neurosurgery · doi:10.3171/jns.1999.90.6.1025 · Cited by 154
Tateshima, S., Murayama, Y., Gobin, Y. P., Duckwiler, G., Guglielmi, G., & Viñuela, F. V. (2000) · Neurosurgery · doi:10.1097/00006123-200012000-00012 · Cited by 152
Lempert, T. E., Malek, A. M., Halbach, V. V., Phatouros, C. C., Meyers, P. M., Dowd, C. F., & Higashida, R. T. (2000) · Stroke · doi:10.1161/01.str.31.1.100 · Cited by 152
Henkes, H. H., Bose, A., Felber, S. R., Miloslavski, E., Berg-Dammer, E., & Kühne, D. (2002) · Interventional Neuroradiology · doi:10.1177/159101990200800202 · Cited by 141
Self-citationCronqvist, M., Pierot, L., Boulin, A., Cognard, C., Castaings, L., & Moret, J. (1998) · PubMed · Cited by 133
A comparison between endovascular and surgical management of basilar artery apex aneurysms
Gruber, D. P., Zimmerman, G. A., Tomsick, T. A., van Loveren, H. R., Link, M. J., & Tew, J. M. (1999) · Journal of neurosurgery · doi:10.3171/jns.1999.90.5.0868 · Cited by 127
Cloft, H. J., Joseph, G. J., Tong, F. C., Goldstein, J. H., & Dion, J. E. (2000) · PubMed Central · Cited by 122
McDougall, C. G., Halbach, V. V., Dowd, C. F., Higashida, R. T., Larsen, D. W., & Hieshima, G. B. (1998) · Journal of neurosurgery · doi:10.3171/jns.1998.89.1.0087 · Cited by 117
Guglielmi Detachable Coil Embolization of Posterior Circulation Aneurysms
Lozier, A. P., Connolly, E. S., Lavine, S. D., & Solomon, R. A. (2002) · Stroke · doi:10.1161/01.str.0000031928.71695.a9 · Cited by 113
Endovascular treatment of Hunt and Hess grade IV and V aneuryms.
Bracard, S., Lebedinsky, A. P., Anxionnat, R., Neto, J. M., Audibert, G., Long, Y., & Picard, L. (2002) · PubMed Central · Cited by 104
Dense packing of cerebral aneurysms: an in vitro study with detachable platinum coils.
Piotin, M., Mandai, S., Murphy, K. J., Sugiu, K., Gailloud, P., Martin, J. B., & Rüfenacht, D. A. (2000) · PubMed · Cited by 100
Rupture of Intracranial Aneurysms during Endovascular Coiling: Management and Outcomes
Levy, E. I., Koebbe, C. J., Horowitz, M. B., Jungreis, C. A., Pride, G. L., Dutton, K., Kassam, A. B., & Purdy, P. D. (2001) · Neurosurgery · doi:10.1097/00006123-200110000-00005 · Cited by 84
Alexander, M. J., Duckwiler, G., Gobin, Y. P., & Viñuela, F. (2002) · Neurosurgery · doi:10.1097/00006123-200204000-00045 · Cited by 49
Endovascular management of unruptured intracranial aneurysms: does outcome justify treatment?
Goddard, A. J. P., Annesley-Williams, D. J., & Gholkar, A. R. (2002) · PubMed Central · doi:10.25405/ncl.34647501 · Cited by 46
Endovascular treatment of Hunt and Hess grade IV and V aneurysms.
Loon, J. V., & Wilms, G. (2003) · PubMed · Cited by 25
Kähärä, V. J., Seppänen, S., Kuurne, T., & LAASONEN, E. M. (1999) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1999.tb00677.x · Cited by 24
Intraarterial Thrombolysis for Thromboemboli Associated with Endovascular Aneurysm Coiling
Koebbe, C. J., Horowitz, M. B., Levy, E. I., Dutton, K., Jungries, C. A., & Purdy, P. D. (2002) · Interventional Neuroradiology · doi:10.1177/159101990200800207 · Cited by 20
Cited by
Brisman, J. L., Song, J. K., & Newell, D. W. (2006) · New England Journal of Medicine · doi:10.1056/nejmra052760 · Cited by 896
Stent-Supported Aneurysm Coiling: A Literature Survey of Treatment and Follow-Up
Shapiro, M., Becske, T., Sahlein, D., Babb, J., & Nelson, P. K. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2719 · Cited by 244
Ries, T., Siemonsen, S., Thomalla, G., Grzyska, U., Zeumer, H., & Fiehler, J. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0649 · Cited by 186
Small, W., Buckley, P. R., Wilson, T. S., Benett, W. J., Hartman, J., Saloner, D., & Maitland, D. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889771 · Cited by 124
“Saccular aneuryms with a relatively narrow neck are generally treated endovascularly by coil embolization [2], a procedure in which the aneurysm lumen is filled with detachable”
Metadata
- Authors
- Henkes, H., Fischer, S., Weber, W., Miloslavski, E., Felber, S., Brew, S., & Kuehne, D.
- Venue
- Neurosurgery
- Published
- 2004-02-01
- Volume
- 54
- Issue
- 2
- Pages
- 268-285
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W1983924397
- Cited by
- 322
- References
- 36
- FWCI
- 15.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.