CoChat

Motor Evoked Potential Monitoring with Supratentorial Surgery

Neuloh, Georg, Pechstein, Ulrich, Cedzich, Cornelia, Schramm, Johannes · 2004 · Neurosurgery
Cited by 233

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess feasibility and clinical value of motor evoked potential (MEP) monitoring with surgery close to supratentorial motor areas and pathways. METHODS: Functional mapping by somatosensory evoked potential phase reversal and continuous MEP recording after high-frequency repetitive electrical cortex stimulation was performed during 182 operations in 177 patients. Significant MEP changes were reported to trigger surgical reaction. Intraoperative surgical and electrophysiological findings were documented prospectively. Patient files were reviewed for clinical data. MEP monitoring results were correlated with motor outcome. RESULTS: MEP recording was successful in 167 cases (91.8%). Inadequate electrode placement was an important reason for failed recording in the remaining patients, whereas preoperative paresis and anesthesia had no significant effect. Permanently disabling new motor deficit occurred in 8 cases (4.9%), whereas transient and nondisabling weakness was frequent (27.4%). Significant MEP changes occurred during 64 operations (39%). Irreversible MEP loss always predicted new, usually permanent, paresis. Unaltered MEP recordings indicated unimpaired motor function in the monitored muscle groups, except for rare transient deficit because of late edema and rebleeding. Irreversible MEP deterioration without loss and reversible changes could be associated with new paresis, which was transient in most patients. No major complications were observed, except for intraoperative generalized seizure in one epilepsy patient under insufficient anticonvulsant therapy. CONCLUSION: MEP monitoring with supratentorial surgery is feasible and safe. It may help to maximize resection within the limits of preserved motor function. Further evidence is needed to confirm these results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000119326.15032.00

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 233

Metadata

Authors
Neuloh, G., Pechstein, U., Cedzich, C., & Schramm, J.
Venue
Neurosurgery
Published
2004-05
Volume
54
Issue
5
Pages
1061-1072
ISSN
0148-396X (ISSN-L)
OpenAlex
W2066004126
Cited by
233
References
34
FWCI
8.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.