Functional Identification of the Primary Motor Area by Corticospinal Tractography
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: For quick and stable identification of the primary motor area (PMA), diffusion tensor imaging (DTI) data were acquired and corticospinal tractography was mathematically visualized. METHODS: Data sets of DTI, anatomic magnetic resonance imaging, and functional magnetic resonance imaging with finger-tapping tasks were acquired during the same investigation in 30 patients with a brain lesion affecting the motor system. Off-line processing of DTI data was performed to visualize the corticospinal tract, placing a seed area in the cerebral peduncle of the midbrain, where the corticospinal tract is densely concentrated. Somatosensory evoked magnetic fields and intraoperative cortical somatosensory evoked potentials were recorded with electrical stimulation of the median nerve to confirm the results of the corticospinal tractography. RESULTS: Functional magnetic resonance imaging and somatosensory evoked magnetic fields failed to identify the PMA in eight patients (16.7%) and one patient (3.8%) investigated, respectively, because of cortical dysfunctions caused by brain lesions. DTI data were acquired within 3 minutes without patient tasks. Using the appropriate seed area and fractional anisotropy, corticospinal tractography successfully indicated the PMA location in all patients. The suspected PMA and central sulcus locations were confirmed by the cortical somatosensory evoked potentials. CONCLUSION: Corticospinal tractography enables identification of the PMA and is beneficial, particularly for patients who present with dysfunction of the PMA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Fiber tracking: principles and strategies – a technical review
Mori, S., & van Zijl, P. C. M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.781 · Cited by 2,024 · cited 1×
“It has recently become possible to visualize the major axonal fascicles in vivo in the human brain by selecting regions with high FA values as seed areas for the three-dimensional tracking process (tractography) (15, 16, 20, 21).”
BackgroundJellison, B. J., Field, A. S., Medow, J. E., Lazar, M., Salamat, M. S., & Alexander, A. L. (2004) · PubMed Central · Cited by 805
Tracing Neural Connections with Horseradish Peroxidase
Mesulam, M. M. (1982) · Medical Entomology and Zoology · Cited by 531
Diffusion Tensor Imaging and Axonal Tracking in the Human Brainstem
Stieltjes, B., Kaufmann, W. E., van Zijl, P. C. M., Fredericksen, K., Pearlson, G. D., Solaiyappan, M., & Mori, S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0861 · Cited by 492 · cited 2×
“It has recently become possible to visualize the major axonal fascicles in vivo in the human brain by selecting regions with high FA values as seed areas for the three-dimensional tracking process (tractography) (15, 16, 20, 21).”
BackgroundA Fully Automatic Multimodality Image Registration Algorithm
Ardekani, B. A., Braun, M., Hutton, B. F., Kanno, I., & Iida, H. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199507000-00022 · Cited by 310 · cited 1×
“Within each defined cluster on the functional data sets, the algorithm iteratively updated the registration parameters using affine transformation to minimize results of the cost function, which evaluated the spatial difference between anatomic and functional data sets (2).”
MethodBrain white matter anatomy of tumor patients evaluated with diffusion tensor imaging
Mori, S., Frederiksen, K., van Zijl, P. C. M., Stieltjes, B., Kraut, M. A., Solaiyappan, M., & Pomper, M. G. (2002) · Annals of Neurology · doi:10.1002/ana.10137 · Cited by 279
Maier, M. A. (2002) · Cerebral Cortex · doi:10.1093/cercor/12.3.281 · Cited by 275 · cited 1×
“(13) made a quantitative comparison of the density of the CST projections from the PMA and SMA to the spinal motor nuclei in macaque monkeys.”
BackgroundHolodny, A. I., Schulder, M., Liu, W., Wolko, J., Maldjian, J. A., & Kalnin, A. (2000) · PubMed Central · Cited by 256
Cited by
Deer, T. R., Mekhail, N., Provenzano, D., Pope, J., Krames, E., Leong, M., Levy, R. M., Abejon, D., Buchser, E., Burton, A., et al. (2014) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12208 · Cited by 596
Chou, R., Loeser, J. D., Owens, D. K., Rosenquist, R. W., Atlas, S. J., Baisden, J., Carragee, E. J., Grabois, M., Murphy, D. R., Resnick, D. K., et al. (2009) · Spine · doi:10.1097/brs.0b013e3181a1390d · Cited by 581
Chou, R., Atlas, S. J., Stanos, S. P., & Rosenquist, R. W. (2009) · Spine · doi:10.1097/brs.0b013e3181a103b1 · Cited by 392
Spinal Cord Stimulation: Clinical Efficacy and Potential Mechanisms
Sdrulla, A. D., Guan, Y., & Raja, S. N. (2018) · Pain Practice · doi:10.1111/papr.12692 · Cited by 375
Wu, J.-S., Zhou, L.-F., Tang, W.-J., Mao, Y., Hu, J., Song, Y.-Y., Hong, X.-N., & Du, G.-H. (2007) · Neurosurgery · doi:10.1227/01.neu.0000303189.80049.ab · Cited by 361
Deer, T. R., Pope, J. E., Hayek, S. M., Bux, A., Buchser, E., Eldabe, S., De Andrés, J. A., Erdek, M., Patin, D., Grider, J. S., et al. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12538 · Cited by 358
Three-dimensional microsurgical and tractographic anatomy of the white matter of the human brain
Fernández-Miranda, J. C., Rhoton, A. L., Álvarez-Linera, J., Kakizawa, Y., Choi, C., & de Oliveira, E. P. (2008) · Neurosurgery · doi:10.1227/01.neu.0000333767.05328.49 · Cited by 347
Diffusion-Tensor MR Imaging and Tractography: Exploring Brain Microstructure and Connectivity
Nucifora, P. G. P., Verma, R., Lee, S.-K., & Melhem, E. R. (2007) · Radiology · doi:10.1148/radiol.2452060445 · Cited by 344
Wrigley, P. J., Gustin, S. M., Macey, P. M., Nash, P. G., Gandevia, S. C., Macefield, V. G., Siddall, P. J., & Henderson, L. A. (2009) · Cerebral Cortex · doi:10.1093/cercor/bhn072 · Cited by 238
Liem, L., Russo, M., Huygen, F. J. P. M., Van Buyten, J.-P., Smet, I., Verrills, P., Cousins, M., Brooker, C., Levy, R., Deer, T., et al. (2013) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12072 · Cited by 237
Fernandez-Miranda, J. C., Pathak, S., Engh, J., Jarbo, K., Verstynen, T., Yeh, F.-C., Wang, Y., Mintz, A., Boada, F., Schneider, W., et al. (2012) · Neurosurgery · doi:10.1227/neu.0b013e3182592faa · Cited by 236
Schu, S., Slotty, P. J., Bara, G., von Knop, M., Edgar, D., & Vesper, J. (2014) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12197 · Cited by 206
Deer, T. R., Mekhail, N., Provenzano, D., Pope, J., Krames, E., Thomson, S., Raso, L., Burton, A., DeAndres, J., Buchser, E., et al. (2014) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12206 · Cited by 204
Functional MRI is a valid noninvasive alternative to Wada testing
Binder, J. R. (2011) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2010.08.004 · Cited by 197
Kumar, K., North, R., Taylor, R., Sculpher, M., Van den Abeele, C., Gehring, M., Jacques, L., Eldabe, S., Meglio, M., Molet, J., et al. (2005) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2005.00027.x · Cited by 194
The Cost-effectiveness of Spinal Cord Stimulation in the Treatment of Failed Back Surgery Syndrome
Taylor, R. S., Ryan, J., O'Donnell, R., Eldabe, S., Kumar, K., & North, R. B. (2010) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e3181daccec · Cited by 193
Implementation of Fiber Tract Navigation
Nimsky, C., Ganslandt, O., & Fahlbusch, R. (2006) · Operative Neurosurgery · doi:10.1227/01.neu.0000204726.00088.6d · Cited by 189
Novel Spinal Cord Stimulation Parameters in Patients with Predominant Back Pain
Tiede, J., Brown, L., Gekht, G., Vallejo, R., Yearwood, T., & Morgan, D. (2013) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12032 · Cited by 184
Perruchoud, C., Eldabe, S., Batterham, A. M., Madzinga, G., Brookes, M., Durrer, A., Rosato, M., Bovet, N., West, S., Bovy, M., et al. (2013) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12027 · Cited by 177
Kinoshita, M., Hashimoto, N., Goto, T., Kagawa, N., Kishima, H., Izumoto, S., Tanaka, H., Fujita, N., & Yoshimine, T. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.06.041 · Cited by 176
“…tensor MR imaging (DTI), has attracted great interest in that it can provide neural fiber information by use of the fiber-tracking technique (Kamada et al., 2005a; Kamada et al., 2005b; Kinoshita et al., 2005; Mikuni et al., 2007; Mori et al., 2002; Nimsky et al., 2006a; Nimsky et al.,…”
Fernández-Miranda, J. C., Rhoton, A. L., Kakizawa, Y., Choi, C., & Álvarez-Linera, J. (2008) · Journal of Neurosurgery · doi:10.3171/jns/2008/108/4/0764 · Cited by 171
Deer, T. R., Pope, J. E., Lamer, T. J., Grider, J. S., Provenzano, D., Lubenow, T. R., FitzGerald, J. J., Hunter, C., Falowski, S., Sayed, D., et al. (2019) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12845 · Cited by 165
Deer, T. R., Provenzano, D. A., Hanes, M., Pope, J. E., Thomson, S. J., Russo, M. A., McJunkin, T., Saulino, M., Raso, L. J., Lad, S. P., et al. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12565 · Cited by 161
Neural Interface Devices: Spinal Cord Stimulation Technology
North, R. B. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922558 · Cited by 59
Metadata
- Authors
- Kamada, K., Sawamura, Y., Takeuchi, F., Kawaguchi, H., Kuriki, S., Todo, T., Morita, A., Masutani, Y., Aoki, S., & Kirino, T.
- Venue
- Operative Neurosurgery
- Published
- 2005-01
- Volume
- 56
- Issue
- 1 Suppl
- Pages
- 98-109
- ISSN
- 2332-4252 (ISSN-L)
- OpenAlex
- W2042028453
- Cited by
- 241
- References
- 21
- FWCI
- 10.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.