CoChat

A Microdialysis Technique for Routine Measurement of Macromolecules in the Injured Human Brain

Hillman, Jan, Åneman, Oscar, Anderson, Chris, Sjögren, Florence, Säberg, Carina, Mellergård, Pekka · 2005 · Neurosurgery
Cited by 113

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To evaluate a new intracerebral microdialysis catheter with a high-cutoff membrane and its potential for the study of macromolecules in the human brain. METHODS: Paired intracerebral microdialysis catheters were inserted in 10 patients who became comatose after subarachnoid hemorrhage or traumatic brain injury and were then treated in our neurosurgical unit. The only differences from the routine use of microdialysis in our clinic were the length (20 mm) and cutoff properties of the catheter membranes (100 kD) and the perfusion fluids used (standard perfusion fluid, 3.5% albumin, or Ringer-dextran 60). Samples were weighed (for net fluid fluxes) and analyzed at bedside (for routine metabolites) and later in the laboratory (for total protein and interleukin-6). The in vitro recovery of glucose, glutamate, and glycerol were also investigated under different conditions. RESULTS: Even brief perfusion with standard perfusion fluid resulted in a significant loss of volume from the microdialysis system. For albumin and Ringer-dextran 60 fluid, recovery was comparable to standard settings. Interleukin-6 (highest value close to 25,000 pg/ml) was sampled from all catheters, and total protein was analyzed from catheters perfused with Ringer-dextran 60 (average concentration, 234 mug protein/ml). There were detectable patterns of variations in the concentration of interleukin-6, seemingly related to concomitant variations in intracerebral conditions. In the present study, no direct comparison was made with the standard CMA 70 catheter (CMA Microdialysis, Stockholm, Sweden), but in vivo, the measured mean concentrations of glucose, glycerol, lactate, and pyruvate were comparable to those previously reported from standard catheters. In vitro, the recovery of metabolites was better when using Ringer-dextran 60 compared with albumin. CONCLUSION: Microdialysis catheters with high-cutoff membranes can be used in routine clinical practice, allowing for sampling and analysis of cytokines and other macromolecules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000159711.93592.8d

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 113

Metadata

Authors
Hillman, J., Åneman, O., Anderson, C., Sjögren, F., Säberg, C., & Mellergård, P.
Venue
Neurosurgery
Published
2005-06-01
Volume
56
Issue
6
Pages
1264-1270
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2078295190
Cited by
113
References
0
FWCI
2.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Microdialysis Technique for Routine Measurement of Macromolecules in the Injured Human Brain. https://app.cochat.ai/papers/10.1227/01.neu.0000159711.93592.8d
The paper
Hillman, J., Åneman, O., Anderson, C., Sjögren, F., Säberg, C., & Mellergård, P. (2005). A Microdialysis Technique for Routine Measurement of Macromolecules in the Injured Human Brain. Neurosurgery. https://doi.org/10.1227/01.neu.0000159711.93592.8d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.