CoChat

LOCALIZATION OF CEREBROSPINAL FLUID LEAKS BY GADOLINIUM-ENHANCED MAGNETIC RESONANCE CISTERNOGRAPHY: A 5-YEAR SINGLE-CENTER EXPERIENCE

Aydin, Kubilay, Terzibasioglu, Ege, Sencer, Serra, Sencer, Altay, Suoglu, Yusufhan, Karasu, Aykut, Kiris, Talat, Turantan, M. Inan · 2008 · Neurosurgery
Cited by 68

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Intrathecal gadolinium (Gd)-enhanced magnetic resonance (MR) cisternography is a newly introduced imaging method. Two main objectives of this study were to investigate the sensitivity of Gd-enhanced MR cisternography for presurgical localization of cerebrospinal fluid (CSF) leaks in patients with CSF rhinorrhea and to study the potential long-term adverse effects of intrathecal Gd application. METHODS: Fifty-one patients (19 women; mean age, 36.2 yr) with CSF rhinorrhea were included in the study. A total of 0.5 ml of Gd was injected into the lumbar subarachnoid space. T1-weighted MR cisternographic images were obtained to detect CSF leakage. The patient's neurological states and vital signs were recorded for the first 24 hours after the procedure. Neurological evaluations were repeated 1, 3, and 12 months after the procedure. The patients were followed for at least 3 years with annual neurological examinations. RESULTS: Gd-enhanced MR cisternography demonstrated CSF leaks in 43 of the 51 patients. The sensitivity of Gd-enhanced MR cisternography for localization of CSF leaks was 84%. Forty-four patients underwent surgery to repair dural tears. Surgical findings confirmed the results of Gd-enhanced cisternography in 43 of the 44 patients who underwent surgery (98%). Eight patients with negative Gd-enhanced MR cisternography had no active rhinorrhea at the time of procedure, and seven of them did not need surgery. None of the patients developed an acute adverse reaction that could be attributed to the procedure. None of the patients developed any neurological symptoms or signs caused by intrathecal Gd injection during a mean follow-up period of 4.12 years. CONCLUSION: Gd-enhanced MR cisternography is a sensitive and safe imaging method for detection of CSF leaks in patients with rhinorrhea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000317306.39203.24

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 68

Metadata

Authors
Aydin, K., Terzibasioglu, E., Sencer, S., Sencer, A., Suoglu, Y., Karasu, A., Kiris, T., & Turantan, M. I.
Venue
Neurosurgery
Published
2008-03
Volume
62
Issue
3
Pages
584-589
ISSN
0148-396X (ISSN-L)
OpenAlex
W2069394941
Cited by
68
References
0
FWCI
4.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: LOCALIZATION OF CEREBROSPINAL FLUID LEAKS BY GADOLINIUM-ENHANCED MAGNETIC RESONANCE CISTERNOGRAPHY: A 5-YEAR SINGLE-CENTER EXPERIENCE. https://app.cochat.ai/papers/10.1227/01.neu.0000317306.39203.24
The paper
Aydin, K., Terzibasioglu, E., Sencer, S., Sencer, A., Suoglu, Y., Karasu, A., Kiris, T., & Turantan, M. I. (2008). LOCALIZATION OF CEREBROSPINAL FLUID LEAKS BY GADOLINIUM-ENHANCED MAGNETIC RESONANCE CISTERNOGRAPHY: A 5-YEAR SINGLE-CENTER EXPERIENCE. Neurosurgery. https://doi.org/10.1227/01.neu.0000317306.39203.24

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.