REOPERATION FOR SUBOPTIMAL OUTCOMES AFTER DEEP BRAIN STIMULATION SURGERY
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To examine a case series of reoperations for deep brain stimulation (DBS) leads in which clinical scenarios revealed suboptimal outcome from a previous operation. Suboptimally placed DBS leads are one potential reason for unsatisfactory results after surgery for Parkinson's disease (PD), essential tremor (ET), or dystonia. In a previous study of patients who experienced suboptimal results, 19 of 41 patients had misplaced leads. Similarly, another report commented that lead placement beyond a 2- to 3-mm window resulted in inadequate clinical benefit, and, in 1 patient, revision improved outcome. The goal of the current study was to perform an unblinded retrospective chart review of DBS patients with unsatisfactory outcomes who presented for reoperation. METHODS: Patients who had DBS lead replacements after reoperation were assessed with the use of a retrospective review of an institutional review board-approved movement disorders database. Cases of reoperation for suboptimal clinical benefit were included, and cases of replacement of DBS leads caused by infection or hardware malfunction were excluded. Data points studied included age, disease duration, diagnosis, motor outcomes (the Unified Parkinson Disease Rating Scale III in PD, the Tremor Rating Scale in ET, and the Unified Dystonia Rating Scale in dystonia), quality of life (Parkinson's Disease Questionnaire-39 in PD), and the Clinician Global Impression scale. The data from before and after reoperation were examined to determine the estimated impact of repeat surgery. RESULTS: There were 11 patients with PD, 7 with ET, and 4 with dystonia. The average age of the PD group was 52 years, the disease duration was 10 years, and the average vector distance of the location of the active DBS contact was adjusted 5.5 mm. Six patients (54%) with PD had preoperative off medication on DBS Unified Parkinson Disease Rating Scale scores that could be compared with postoperative off medication on DBS scores. The average improvement across this group of patients was 24.4%. The Parkinson's Disease Questionnaire-39 improved in the areas of mobility (28.18), activities of daily living (14.77), emotion (14.72), stigma (17.61), and discomfort (17.42). The average age of the ET group was 66 years, the disease duration was 29 years, and the average adjusted distance was 6.1 mm. Five ET patients (83.3%) in the cohort had a prereplacement on DBS Tremor Rating Scale and a postreplacement on DBS Tremor Rating Scale with the average improvement of 60.4%. The average age of the dystonia group was 39 years, the average disease duration was 7 years, and the average adjusted lead distance was 6.7 mm. Three patients (75%) with dystonia had prereplacement on DBS Unified Dystonia Rating Scale and postreplacement on DBS Unified Dystonia Rating Scale scores. Across these 3 dystonia patients, the improvement was 12.8%. Clinician Global Impression scale scores (1, very much improved; 2, much improved; 3, minimally improved; 4, no change; 5, minimally worse; 6, much worse; 7, very much worse) after replacement revealed the following results in patients with PD: 1, 7 patients; 2, 3 patients; 3, 1 patient); with ET (1, 4 patients; 2, 3 patients); and with dystonia (1, 1 patient; 2, 2 patients; 3, 1 patient). The latency from original lead placement to reoperation (repositioning/revision) overall was 28.9 months (range, 2-104 mo); however, in leads referred from outside institutions (n = 11 patients), this latency was 48 months (range, 12-104 mo) compared with leads implanted by surgeons from the University of Florida (n = 11 patients), which was 9.7 months (range, 2-19 mo). The most common clinical history was failure to achieve a perceived outcome; however, history of an asymmetric benefit was present in 4 (18.2%) of 22 patients, and lead migration was present in 3 (13.6%) of 22 patients. CONCLUSION: There are many potential causes of suboptimal benefit after DBS. Timely identification of suboptimal lead placements followed by reoperation and repositioning/replacement in a subset of patients may improve outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subthalamic nucleus deep brain stimulation: Summary and meta-analysis of outcomes
Kleiner-Fisman, G., Herzog, J., Fisman, D. N., Tamma, F., Lyons, K. E., Pahwa, R., Lang, A. E., & Deuschl, G. (2006) · Movement Disorders · doi:10.1002/mds.20962 · Cited by 957
Plaha, P. (2006) · Brain · doi:10.1093/brain/awl127 · Cited by 515
Okun, M. S., Tagliati, M., Pourfar, M., Fernandez, H. H., Rodriguez, R. L., Alterman, R. L., & Foote, K. D. (2005) · Archives of Neurology · doi:10.1001/archneur.62.8.noc40425 · Cited by 425
Self-citationStarr, P. A., Christine, C. W., Theodosopoulos, P. V., Lindsey, N., Byrd, D., Mosley, A., & Marks, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.2.0370 · Cited by 415 · cited 2×
“Brain shifts may occur at any time, including preoperative imaging, physiological recording, lead placement, or when a cerebrospinal fluid leak is detected (4, 6, 23, 24).”
BackgroundSurgical and hardware complications of subthalamic stimulation: A series of 160 procedures
Lyons, K. E., Wilkinson, S. B., Overman, J., & Pahwa, R. (2004) · Neurology · doi:10.1212/01.wnl.0000134650.91974.1a · Cited by 271 · cited 1×
“Lead deflection is also possible and may result from changes in tissue density, the angle of approach, or collision with the burr hole or the capping device (10, 11).”
BackgroundComplications of deep brain stimulation surgery
Hariz, M. I. (2002) · Movement Disorders · doi:10.1002/mds.10159 · Cited by 267
Short-term and long-term safety of deep brain stimulation in the treatment of movement disorders
Kenney, C., Simpson, R., Hunter, C., Ondo, W., Almaguer, M., Davidson, A., & Jankovic, J. (2007) · Journal of Neurosurgery · doi:10.3171/jns.2007.106.4.621 · Cited by 221
Starr, P. A. (2002) · Stereotactic and Functional Neurosurgery · doi:10.1159/000070828 · Cited by 214 · cited 2×
“Brain shifts may occur at any time, including preoperative imaging, physiological recording, lead placement, or when a cerebrospinal fluid leak is detected (4, 6, 23, 24).”
BackgroundHardware-Related Complications of Deep Brain Stimulation: A Review of the Published Literature
Hamani, C., & Lozano, A. M. (2006) · Stereotactic and Functional Neurosurgery · doi:10.1159/000096499 · Cited by 212
Thirty days complication rate following surgery performed for deep‐brain‐stimulation
Voges, J., Hilker, R., Bötzel, K., Kiening, K. L., Kloss, M., Kupsch, A., Schnitzler, A., Schneider, G., Steude, U., Deuschl, G., et al. (2007) · Movement Disorders · doi:10.1002/mds.21481 · Cited by 203
Cited by
Connectivity Predicts deep brain stimulation outcome in Parkinson disease
Horn, A., Reich, M., Vorwerk, J., Li, N., Wenzel, G., Fang, Q., Schmitz‐Hübsch, T., Nickl, R., Kupsch, A., Volkmann, J., et al. (2017) · Annals of Neurology · doi:10.1002/ana.24974 · Cited by 711
Bot, M., van den Munckhof, P., Bakay, R., Stebbins, G., & Verhagen Metman, L. (2017) · Stereotactic and Functional Neurosurgery · doi:10.1159/000475672 · Cited by 671
Lead-DBS: A toolbox for deep brain stimulation electrode localizations and visualizations
Horn, A., & Kühn, A. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.002 · Cited by 667
Deep-Brain Stimulation for Parkinson's Disease
Okun, M. S. (2012) · New England Journal of Medicine · doi:10.1056/nejmct1208070 · Cited by 541
Self-citationFenoy, A. J., & Simpson, R. K. (2014) · Journal of Neurosurgery · doi:10.3171/2013.10.jns131225 · Cited by 449
Goodman, W. K., Foote, K. D., Greenberg, B. D., Ricciuti, N., Bauer, R., Ward, H., Shapira, N. A., Wu, S. S., Hill, C. L., Rasmussen, S. A., et al. (2010) · Biological Psychiatry · doi:10.1016/j.biopsych.2009.11.028 · Cited by 362
Self-citationDeep brain stimulation for Parkinson's disease
Hariz, M., & Blomstedt, P. (2022) · Journal of Internal Medicine · doi:10.1111/joim.13541 · Cited by 256
Ramirez-Zamora, A., Giordano, J., Boyden, E. S., Gradinaru, V., Gunduz, A., Starr, P. A., Sheth, S. A., McIntyre, C. C., Fox, M. D., Vitek, J., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00936 · Cited by 37
Self-citation
Metadata
- Authors
- Ellis, T.-M., Foote, K. D., Fernandez, H. H., Sudhyadhom, A., Rodriguez, R. L., Zeilman, P., Jacobson, C. E., & Okun, M. S.
- Venue
- Neurosurgery
- Published
- 2008-10
- Volume
- 63
- Issue
- 4
- Pages
- 754-761
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2086254481
- Cited by
- 172
- References
- 28
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.