OBJECTIVE: Detailed investigations of cortical physiology require the ability to record brain electrical activity at a submillimeter scale. Standard intracranial electrodes result in significant averaging of potentials generated by large numbers of neurons. In contrast, microelectrode arrays allow for recording of local field potentials and single-unit activity. We describe our initial surgical experience with the NeuroPort microelectrode array (Cyberkinetics Neurotechnology Systems, Inc., Salt Lake City, UT) in a series of patients undergoing subdural electrode implantation for epilepsy monitoring. METHODS: Seven patients were implanted with and underwent semichronic recording from the NeuroPort array during standard subdural electrode monitoring for epilepsy. The electrode was placed according to company specifications in putative noneloquent epileptogenic cortex. After the monitoring period, microelectrode arrays were removed during explantation of subdural electrodes and resection of epileptogenic tissue. RESULTS: Successful implantation of the microelectrode array was achieved in all patients, with minor operative difficulties. Robust and durable local field potentials and single-unit recordings were obtained from all implanted individuals. Implantation times ranged from 3 to 28 days; histological analysis of implanted tissue demonstrated no significant tissue injury or inflammatory response. There were no neurological complications or infections associated with electrode implantation or prolonged monitoring. Two patients developed postresection issues with wound healing at the site of scalp egress, with 1 requiring operative wound revision. CONCLUSION: Our experience demonstrates that semichronic microelectroencephalographic recording can be safely and effectively achieved using the NeuroPort microarray. Although significant tissue injury, infection, or cerebrospinal fluid leak was not encountered, the large profile of the connection pedestal resulted in suboptimal wound closure and healing in several patients. We predict that this problem will be easily addressed in second-generation devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“(3) in a small cohort of patients with spinal cord injury/disease implanted with the NeuroPort MEA (called the BrainGate system at that time) as part of a clinical trial of a neuroprosthetic application.”
BackgroundMethod
Research works printed but not linked: 6
- Bartfeld, 1992, Relationships between orientation-preference pinwheels, cytochrome oxidase blobs, and ocular dominance columns in primate striate cortex., Proc Natl Acad Sci U S A, 89, 11905, 10.1073/pnas.89.24.11905 · DOI · Paper page
- Ebersole, 1997, Defining epileptogenic foci: Past, present, future., J Clin Neurophysiol, 14, 470, 10.1097/00004691-199711000-00003 · DOI · Paper page
- Kossoff, 2004, Effect of an external responsive neurostimulator on seizures and electrographic discharges during subdural electrode monitoring., Epilepsia, 45, 1560, 10.1111/j.0013-9580.2004.26104.x · DOI · Paper page
- Morrell, 2006, Brain stimulation for epilepsy: Can scheduled or responsive neurostimulation stop seizures?, Curr Opin Neurol, 19, 164, 10.1097/01.wco.0000218233.60217.84 · DOI · Paper page
- Mountcastle, 1997, The columnar organization of the neocortex., Brain, 120, 701, 10.1093/brain/120.4.701 · DOI · Paper page
- Schevon, 2008, Microphysiology of epileptiform activity in human neocortex., J Clin Neurophysiol, 25, 321, 10.1097/WNP.0b013e31818e8010 · DOI · Paper page
Cited by
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Evidence of an inhibitory restraint of seizure activity in humans
Schevon, C. A., Weiss, S. A., McKhann, G., Goodman, R. R., Yuste, R., Emerson, R. G., & Trevelyan, A. J. (2012) · Nature Communications · doi:10.1038/ncomms2056 · Cited by 425
Self-citationLewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Electrophysiological correlates of the BOLD signal for EEG-informed fMRI
Murta, T., Leite, M., Carmichael, D. W., Figueiredo, P., & Lemieux, L. (2015) · Human Brain Mapping · doi:10.1002/hbm.22623 · Cited by 165
“The availability of microelectrodes combined with the clinical icEEG electrodes is a promising research tool [Fried et al., 1999; Hochberg et al., 2006; Schevon et al., 2012; Waziri et al., 2009].”
Metadata
- Authors
- Waziri, A., Schevon, C. A., Cappell, J., Emerson, R. G., McKhann, G. M., & Goodman, R. R.
- Venue
- Neurosurgery
- Published
- 2009-03
- Volume
- 64
- Issue
- 3
- Pages
- 540-545
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2077800507
- Cited by
- 55
- References
- 1
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: INITIAL SURGICAL EXPERIENCE WITH A DENSE CORTICAL MICROARRAY IN EPILEPTIC PATIENTS UNDERGOING CRANIOTOMY FOR SUBDURAL ELECTRODE IMPLANTATION. https://app.cochat.ai/papers/10.1227/01.neu.0000337575.63861.10
- The paper
- Waziri, A., Schevon, C. A., Cappell, J., Emerson, R. G., McKhann, G. M., & Goodman, R. R. (2009). INITIAL SURGICAL EXPERIENCE WITH A DENSE CORTICAL MICROARRAY IN EPILEPTIC PATIENTS UNDERGOING CRANIOTOMY FOR SUBDURAL ELECTRODE IMPLANTATION. Neurosurgery. https://doi.org/10.1227/01.neu.0000337575.63861.10
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.