The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Defining Epileptogenic Foci: Past, Present, Future
Abstract
There is a direct relationship between the geometry (location, area, and orientation) of cortex-generating epileptiform discharges and resultant spike or seizure voltage fields at the scalp. Epileptogenic foci have been localized traditionally with EEG by identifying the negative field maximum (e.g., a phase reversal between adjacent bipolar channels). However, it is the shape of the entire voltage field over the head, including both negative and positive maxima, which provides information necessary to characterize the focus properly. Source location and orientation can be inferred from spike or seizure voltage topography, however, three-dimensional visualization can be obtained from mathematical source models, such as an equivalent dipole. Recent investigations have shown that dipole models can identify the location of epileptogenic foci with sub-lobar precision. Accuracy is enhanced by using additional electrodes, particularly on the lower half of the head, and by measuring their location. Realistic head models obtained from three-dimensional reconstructions of MR images can overcome errors introduced by simple spherical models of the cranium. Co-registering EEG voltage topography and source models with a patient's own cerebral anatomy will make EEG an unparalleled functional imaging technique for defining epileptogenic foci.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
EEG dipole modeling in complex partial epilepsy
Ebersole, J. S. (1991) · Brain Topography · doi:10.1007/bf01132768 · Cited by 132
Self-citation
Cited by
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Nunez, P. L., & Silberstein, R. B. (2000) · Brain Topography · doi:10.1023/a:1026683200895 · Cited by 307
Pitfalls in the dipolar model for the neocortical EEG sources
Riera, J. J., Ogawa, T., Goto, T., Sumiyoshi, A., Nonaka, H., Evans, A., Miyakawa, H., & Kawashima, R. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00098.2011 · Cited by 98
Noninvasive cortical imaging of epileptiform activities from interictal spikes in pediatric patients
Lai, Y., Zhang, X., van Drongelen, W., Korhman, M., Hecox, K., Ni, Y., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.026 · Cited by 22
Metadata
- Authors
- Ebersole, J. S.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1997-11
- Volume
- 14
- Issue
- 6
- Pages
- 470-483
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W1968350252
- Cited by
- 173
- References
- 2
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Defining Epileptogenic Foci: Past, Present, Future. https://app.cochat.ai/papers/10.1097/00004691-199711000-00003
- The paper
- Ebersole, J. S. (1997). Defining Epileptogenic Foci: Past, Present, Future. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-199711000-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.