Molecular force transduction by ion channels – diversity and unifying principles
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Cells perceive force through a variety of molecular sensors, of which the mechanosensitive ion channels are the most efficient and act the fastest. These channels apparently evolved to prevent osmotic lysis of the cell as a result of metabolite accumulation and/or external changes in osmolarity. From this simple beginning, nature developed specific mechanosensitive enzymes that allow us to hear, maintain balance, feel touch and regulate many systemic variables, such as blood pressure. For a channel to be mechanosensitive it needs to respond to mechanical stresses by changing its shape between the closed and open states. In that way, forces within the lipid bilayer or within a protein link can do work on the channel and stabilize its state. Ion channels have the highest turnover rates of all enzymes, and they can act as both sensors and effectors, providing the necessary fluxes to relieve osmotic pressure, shift the membrane potential or initiate chemical signaling. In this Commentary, we focus on the common mechanisms by which mechanical forces and the local environment can regulate membrane protein structure, and more specifically, mechanosensitive ion channels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316 · cited 8×
“Following that, eukaryotic MSCs belonging to several distinct families have been cloned and functionally characterized (Honoré et al., 2006; Su et al., 2011; Coste et al., 2010; Haswell et al., 2011).”
BackgroundMethodInfluentialDynamic molecular processes mediate cellular mechanotransduction
Hoffman, B. D., Grashoff, C., & Schwartz, M. A. (2011) · Nature · doi:10.1038/nature10316 · Cited by 956 · cited 1×
“The primary structural components of a cell that bear stress and reorganize under forces are the cytoskeleton, the extracellular matrix (ECM) and adhesion complexes (Vogel, 2006; Hoffman et al., 2011), as well as membranes.”
BackgroundInhalational anesthetics activate two-pore-domain background K+ channels
Patel, A. J., Honoré, E., Lesage, F., Fink, M., Romey, G., & Lazdunski, M. (1999) · Nature Neuroscience · doi:10.1038/8084 · Cited by 655 · cited 1×
“These agents activate mechanosensitive 2P K+ channels in neurons, thereby leading to hyperpolarization and decreased excitability, i.e. anesthesia (Patel et al., 1999).”
BackgroundThe Mechanosensitive Ion Channel Piezo1 Is Inhibited by the Peptide GsMTx4
Bae, C., Sachs, F., & Gottlieb, P. A. (2011) · Biochemistry · doi:10.1021/bi200770q · Cited by 566 · cited 5×
“GsMTx4 has no effect on the 2P MSCs (Honoré et al., 2006; Bae et al., 2011b), possibly because the gating structure of K channels is located in the inner monolayer, which is inaccessible to the peptide.”
BackgroundSelf-citation
Cited by
Mechanically Activated Ion Channels
Ranade, S. S., Syeda, R., & Patapoutian, A. (2015) · Neuron · doi:10.1016/j.neuron.2015.08.032 · Cited by 652
Touch, Tension, and Transduction – The Function and Regulation of Piezo Ion Channels
Wu, J., Lewis, A. H., & Grandl, J. (2017) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2016.09.004 · Cited by 570
Integrating the active process of hair cells with cochlear function
Hudspeth, A. J. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3786 · Cited by 385
Mechanics in Neuronal Development and Repair
Franze, K., Janmey, P. A., & Guck, J. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150045 · Cited by 314
GsMTx4: Mechanism of Inhibiting Mechanosensitive Ion Channels
Gnanasambandam, R., Ghatak, C., Yasmann, A., Nishizawa, K., Sachs, F., Ladokhin, A. S., Sukharev, S. I., & Suchyna, T. M. (2017) · Biophysical Journal · doi:10.1016/j.bpj.2016.11.013 · Cited by 258
Self-citationPiezo Proteins: Regulators of Mechanosensation and Other Cellular Processes
Bagriantsev, S. N., Gracheva, E. O., & Gallagher, P. G. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.r114.612697 · Cited by 249
“Perhaps mechanosensitivity depends on the interaction with a regulator protein, such as stomatin-like protein 3 (STOML3), which interacts with both Piezo1 and Piezo2 and positively regulates channel activity (12), or it could be an intrinsic property of the channel, similar to that reported for the bacterial mechanoga…”
BackgroundVersari, S., Longinotti, G., Barenghi, L., Maier, J. A. M., & Bradamante, S. (2013) · The FASEB Journal · doi:10.1096/fj.13-229195 · Cited by 133
Tang, Y., Zhao, C., Zhuang, Y., Zhong, A., Wang, M., Zhang, W., & Zhu, L. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1149336 · Cited by 67
Metadata
- Authors
- Sukharev, S., & Sachs, F.
- Venue
- Journal of Cell Science
- Publisher
- The Company of Biologists
- Published
- 2012-01-01
- Volume
- 125
- Issue
- Pt 13
- Pages
- 3075-83
- ISSN
- 0021-9533 (ISSN-L)
- 1477-9137
- OpenAlex
- W2029681004
- Cited by
- 157
- References
- 4
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.