The DOI matches its Crossref record.
Refractometry of living cells part I. basic principles
Abstract
The principles underlying a new method of refractometry of living cells are discussed. The method was evolved from the chance observation that the amoebocytes of the blood of the earthworm, examined in their own blood, appeared bright instead of dark by positive phase-contrast microscopy. This was shown to be due to the presence of dissolved haemoglobin which raised the refractive index of the medium above that of the cytoplasm. In order to determine the refractive index of the latter it was only necessary to dilute the blood until the cytoplasm became virtually invisible. Non-pigmented proteins and other high molecular weight substances have now been substituted for haemoglobin. The nature of the initial observations suggested that if the cell could be regarded to a first approximation as being composed entirely of proteins, the cytoplasmic protein concentration could be equated to the protein concentration of the immersion medium which made the cell appear with minimum contrast. This would only be true if equal concentrations of different proteins in solution had the same refractive index. The nature of refractive index and its relationship to density are discussed and it is shown that for nearly all unconjugated proteins so far investigated the specific refraction increments (i.e. the increase in refractive index per 1 per cent, increase in concentration) have almost the same values (00185±2 per cent.). The effects of many factors such as pH, salts, temperature, wavelength, concentration, and nature of the solvent are discussed. Since living cells contain substances other than proteins the specific refraction increments of protein derivatives, lipides, carbohydrates, and salts are considered and it is shown that the presence of moderate amounts of such substances is unlikely to affect the refractive index of cells to any great extent. It is suggested that the mean specific refraction increment of protoplasm should be taken as 0018 and that this value can be used in order to calculate the solid and water content of protoplasm from values of refractive index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guck, J., Schinkinger, S., Lincoln, B., Wottawah, F., Ebert, S., Romeyke, M., Lenz, D., Erickson, H. M., Ananthakrishnan, R., Mitchell, D., et al. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.045476 · Cited by 1,417
The Optical Stretcher: A Novel Laser Tool to Micromanipulate Cells
Guck, J., Ananthakrishnan, R., Mahmood, H., Moon, T. J., Cunningham, C. C., & Käs, J. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75740-2 · Cited by 977
Nuclear Architecture of Rod Photoreceptor Cells Adapts to Vision in Mammalian Evolution
Solovei, I., Kreysing, M., Lanctôt, C., Kösem, S., Peichl, L., Cremer, T., Guck, J., & Joffe, B. (2009) · Cell · doi:10.1016/j.cell.2009.01.052 · Cited by 790
Improved measurements of the erythrocyte geometry
Evans, E., & Fung, Y.-C. (1972) · Microvascular Research · doi:10.1016/0026-2862(72)90069-6 · Cited by 592
Resonant Waveguide Grating Biosensor for Living Cell Sensing
Fang, Y., Ferrie, A. M., Fontaine, N. H., Mauro, J., & Balakrishnan, J. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.077818 · Cited by 383
Light scattering by microorganisms in the open ocean
Stramski, D., & Kiefer, D. A. (1991) · Progress in Oceanography · doi:10.1016/0079-6611(91)90032-h · Cited by 374
Brillouin Optical Microscopy for Corneal Biomechanics
Scarcelli, G., Pineda, R., & Yun, S. H. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8281 · Cited by 354
Refractive Index of the Human Corneal Epithelium and Stroma
Patel, S., Marshall, J., & Fitzke, F. W. (1995) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19950301-09 · Cited by 284
Drug screening at single-organoid resolution via bioprinting and interferometry
Tebon, P. J., Wang, B., Markowitz, A. L., Davarifar, A., Krawczuk, P., Murray, G., Nguyen, H. T. L., Tavanaie, N., Nguyen, T. L., Boutros, P. C., et al. (2021) · doi:10.1101/2021.10.03.462896 · Cited by 155
Refractive index of planktonic cells as a measure of cellular carbon and chlorophyll a content
Stramski, D. (1999) · Deep Sea Research Part I: Oceanographic Research Papers · doi:10.1016/s0967-0637(98)00065-x · Cited by 77
Spectral optical properties of selected photosynthetic microalgae producing biofuels
Lee, E., Heng, R.-L., & Pilon, L. (2013) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2012.08.012 · Cited by 74
Practical application of microsphere samples for benchmarking a quantitative phase imaging system
Kwee, E., Peterson, A., Halter, M., & Elliott, J. (2021) · Cytometry Part A · doi:10.1002/cyto.a.24291 · Cited by 9
Compaction and Segregation of DNA in Escherichia coli
(2024) · doi:10.3390/life14060660 · Cited by 8
Metadata
- Authors
- Barer, R., & Joseph, S.
- Venue
- Journal of Cell Science
- Publisher
- The Company of Biologists
- Published
- 1954-12-01
- Volume
- S3-95
- Issue
- 32
- Pages
- 399-423
- ISSN
- 0021-9533 (ISSN-L)
- 1477-9137
- OpenAlex
- W2149791821
- Cited by
- 164
- References
- 0
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.