The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Refractive Index of the Human Corneal Epithelium and Stroma
Abstract
ABSTRACT BACKGROUND: The refractive index of the cornea must be determined to optically perfect keratorefractive procedures. There are very few empirical measurements of the human corneal refractive index described in the literature. Throughout its depth, the cornea demonstrates regional variations in physiological properties such as swelling/de-swelling characteristics. These properties suggest there may be a difference in the refractive index between the anterior and posterior corneal surfaces. METHODS: The refractive index of the human corneal epithelium of 10 eyes was measured, in vivo, using a modified hand-held refractometer. The refractive indices of the anterior and posterior surfaces of the bare stroma of fresh human corneas were measured using a bench model Abbe refractometer. RESULTS: The mean refractive index of the epithelium, stromal anterior and posterior surfaces were 1.401 (SD ± 0.005), 1.380 (SD ± 0.005), and 1.373 (SD ± 0.001) respectively. CONCLUSIONS: The refractive index of the cornea is not uniform. The calculated dioptric power of the corneal epithelium is approximately -1.40 diopters (D). The varying refractive index does not significantly affect the total dioptric power of the cornea. The varying refractive index of the cornea has the potential to significantly contribute to the overall optical performance of the eye in relation to refractive surgery. The results should be incorporated into mathematical models, comparing and contrasting the optical performance of the eye before and after surgery. [J Refract Surg. 1995;11:100-105.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The structure and transparency of the cornea
Maurice, D. M. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005758 · Cited by 1,129
Photorefractive Keratectomy With an Argon Fluoride Excimer Laser: A Clinical Study
Gartry, D. S., Muir, M. G. K., & Marshall, J. (1991) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19911101-06 · Cited by 231
Self-citationThe thickness-hydration relationship of the cornea
Hedbys, B. O., & Mishima, S. (1966) · Experimental Eye Research · doi:10.1016/s0014-4835(66)80010-6 · Cited by 171
Refractometry of living cells part I. basic principles
Barer, R., & Joseph, S. (1954) · Journal of Cell Science · doi:10.1242/jcs.s3-95.32.399 · Cited by 164
Human Excimer Laser Lamellar Keratectomy
Taylor, D. M., L'Esperance, F. A., Del Pero, R. A., Roberts, A. D., Gigstad, J. E., Klintworth, G., Martin, C. A., & Warner, J. (1989) · Ophthalmology · doi:10.1016/s0161-6420(89)32836-3 · Cited by 162
Optics of the Corneal Epithelium
Simon, G., Ren, Q., Kervick, G. N., & Parel, J.-M. A. (1993) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19930101-10 · Cited by 92
Non-uniform swelling properties of the corneal stroma
Lee, D. C., & WILSON, G. S. (1981) · Current Eye Research · doi:10.3109/02713688109019986 · Cited by 72
Glucose Concentration and Hydration of the Corneal Stroma
Turss, R., Friend, J., Reim, M., & Dohlman, C. H. (2009) · Ophthalmic Research · doi:10.1159/000264570 · Cited by 62
A Comparison of Corneal Stromal Edema Induced From the Anterior or the Posterior Surface*
Cristol, S. M., Edelhauser, H. F., & Lynn, M. (1992) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19920501-09 · Cited by 50
On the metachromatic staining of the corneal tissue and some observations on its transparency
Aurell, G., & Holmgren, H. (1953) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1953.tb02213.x · Cited by 50
Cited by
Biomedical applications of hydrogels: A review of patents and commercial products
Caló, E., & Khutoryanskiy, V. V. (2015) · European Polymer Journal · doi:10.1016/j.eurpolymj.2014.11.024 · Cited by 2,634
Hydrogels as intelligent materials: A brief review of synthesis, properties and applications
Mahinroosta, M., Jomeh Farsangi, Z., Allahverdi, A., & Shakoori, Z. (2018) · Materials Today Chemistry · doi:10.1016/j.mtchem.2018.02.004 · Cited by 551
The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
Muller, L. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.437 · Cited by 424
Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080601-05 · Cited by 379
Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20090813-04 · Cited by 299
Metadata
- Authors
- Patel, S., Marshall, J., & Fitzke, F. W.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 1995-03
- Volume
- 11
- Issue
- 2
- Pages
- 100-141
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W1484131042
- Cited by
- 284
- References
- 11
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Refractive Index of the Human Corneal Epithelium and Stroma. https://app.cochat.ai/papers/10.3928/1081-597x-19950301-09
- The paper
- Patel, S., Marshall, J., & Fitzke, F. W. (1995). Refractive Index of the Human Corneal Epithelium and Stroma. Journal of Refractive Surgery. https://doi.org/10.3928/1081-597x-19950301-09
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.