Acutely altered hemodynamics following venous obstruction in the early chick embryo
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
SUMMARY: In the venous clip model specific cardiac malformations are induced in the chick embryo by obstructing the right lateral vitelline vein with a microclip. Clipping alters venous return and intracardiac laminar blood flow patterns,with secondary effects on the mechanical load of the embryonic myocardium. We investigated the instantaneous effects of clipping the right lateral vitelline vein on hemodynamics in the stage-17 chick embryo. 32 chick embryos HH 17 were subdivided into venous clipped (N=16) and matched control embryos(N=16). Dorsal aortic blood flow velocity was measured with a 20 MHz pulsed Doppler meter. A time series of eight successive measurements per embryo was made starting just before clipping and ending 5h after clipping. Heart rate, peak systolic velocity, time-averaged velocity, peak blood flow,mean blood flow, peak acceleration and stroke volume were determined. All hemodynamic parameters decreased acutely after venous clipping and only three out of seven parameters (heart rate, time-averaged velocity and mean blood flow) showed a recovery to baseline values during the 5h study period. We conclude that the experimental alteration of venous return has major acute effects on hemodynamics in the chick embryo. These effects may be responsible for the observed cardiac malformations after clipping.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Malek, A. M., & Izumo, S. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.4.713 · Cited by 531
Hogers, B., DeRuiter, M. C., Gittenberger-de Groot, A. C., & Poelmann, R. E. (1997) · Circulation Research · doi:10.1161/01.res.80.4.473 · Cited by 232 · cited 6×
“This supports the conclusion of Hogers et al. (1997) that the cardiac malformations observed by them are caused by obstruction of the right lateral vitelline vein.”
InfluentialSelf-citation
Cited by
Primary cilia sensitize endothelial cells for fluid shear stress
Hierck, B. P., Van der Heiden, K., Alkemade, F. E., Van de Pas, S., Van Thienen, J. V., Groenendijk, B. C. W., Bax, W. H., Van der Laarse, A., DeRuiter, M. C., Horrevoets, A. J. G., et al. (2008) · Developmental Dynamics · doi:10.1002/dvdy.21472 · Cited by 187
Self-citationGroenendijk, B. C. W., Hierck, B. P., Vrolijk, J., Baiker, M., Pourquie, M. J. B. M., Gittenberger-de Groot, A. C., & Poelmann, R. E. (2005) · Circulation Research · doi:10.1161/01.res.0000171901.40952.0d · Cited by 166
“(5), the narrow part (6), and the downstream part (7).”
BackgroundSelf-citationBiomechanics of early cardiac development
Goenezen, S., Rennie, M. Y., & Rugonyi, S. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-012-0414-7 · Cited by 94
The development of the heart and microcirculation: role of shear stress
Poelmann, R. E., Gittenberger-de Groot, A. C., & Hierck, B. P. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0304-4 · Cited by 62
Self-citation
Metadata
- Authors
- Stekelenburg-de Vos, S., Ursem, N. T. C., Hop, W. C. J., Wladimiroff, J. W., Gittenberger-de Groot, A. C., & Poelmann, R. E.
- Venue
- Journal of Experimental Biology
- Publisher
- The Company of Biologists
- Published
- 2003-03-15
- Volume
- 206
- Issue
- 6
- Pages
- 1051-1057
- ISSN
- 0022-0949 (ISSN-L)
- 1477-9145
- OpenAlex
- W2147443714
- Cited by
- 61
- References
- 2
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.