A protocol and calibration method for accurate multi-camera field videography
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Stereo videography is a powerful technique for quantifying the kinematics and behavior of animals, but it can be challenging to use in an outdoor field setting. We here present a workflow and associated software for performing calibration of cameras placed in a field setting and estimating the accuracy of the resulting stereoscopic reconstructions. We demonstrate the workflow through example stereoscopic reconstructions of bat and bird flight. We provide software tools for planning experiments and processing the resulting calibrations that other researchers may use to calibrate their own cameras. Our field protocol can be deployed in a single afternoon, requiring only short video clips of light, portable calibration objects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple View Geometry in Computer Vision
Hartley, R., & Zisserman, A. (2004) · doi:10.1017/cbo9780511811685 · Cited by 21,070
Hedrick, T. L. (2008) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/3/3/034001 · Cited by 1,360 · cited 2×
“When using DLT, it is important to obtain calibration points throughout the volume of interest, otherwise reconstruction accuracy may be reduced (Hedrick, 2008).”
MethodSelf-citation
Cited by
Using DeepLabCut for 3D markerless pose estimation across species and behaviors
Nath, T., Mathis, A., Chen, A. C., Patel, A., Bethge, M., & Mathis, M. W. (2019) · Nature Protocols · doi:10.1038/s41596-019-0176-0 · Cited by 1,505
A Thermal Infrared Video Benchmark for Visual Analysis
Wu, Z., Fuller, N., Theriault, D., & Betke, M. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition Workshops · doi:10.1109/cvprw.2014.39 · Cited by 179
“Recent studies have gone beyond the traditional tasks and applied thermal imaging to monitoring of wild animals, noninvasive food inspection, and heat loss detection [1], [2].”
BackgroundSelf-citationDynamic representation of 3D auditory space in the midbrain of the free-flying echolocating bat
Kothari, N. B., Wohlgemuth, M. J., & Moss, C. F. (2018) · eLife · doi:10.7554/elife.29053 · Cited by 54
“The motion tracking system was calibrated with a moving wand-based calibration method (Theriault et al., 2014), resulting in sub-millimeter accuracy and 3D spatial location information of the bat at a frame rate of 300 Hz.”
Method
Metadata
- Authors
- Theriault, D. H., Fuller, N. W., Jackson, B. E., Bluhm, E., Evangelista, D., Wu, Z., Betke, M., & Hedrick, T. L.
- Venue
- Journal of Experimental Biology
- Publisher
- The Company of Biologists
- Published
- 2014-01-01
- Volume
- 217
- Issue
- Pt 11
- Pages
- 1843-8
- ISSN
- 0022-0949 (ISSN-L)
- 1477-9145
- OpenAlex
- W2104126397
- Cited by
- 210
- References
- 2
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.