The DOI matches its Crossref record.
Separate Control Of Anion And Cation Transport In Malpighian Tubules Of Drosophila Melanogaster
Abstract
Microelectrode measurements of basal, apical and transepithelial potentials in the Malpighian tubules of Drosophila melanogaster were obtained under a range of conditions in order to investigate whether each of the three main second messenger systems known to act in the tubules (cyclic AMP, cyclic GMP and Ca2+) acted specifically on either cation or anion transport, or whether they activated both systems. Ion-selective microelectrode determinations of K+ concentration and pH of secreted fluid allowed the role of each signalling system to be analysed further. Stimulation with cyclic nucleotides markedly alters the potential profile across principal cells through the selective activation of an apical electrogenic V-ATPase. By contrast, manipulation of extracellular chloride levels, combined with stimulation with leucokinin, does not affect the potential profile across the principal cells, showing that chloride must pass through another route. The cell-permeant Ca2+ chelator BAPTA-AM was shown to suppress the action of leucokinins (insect peptides that induce rapid fluid secretion), but not those of cyclic AMP, the neuronally derived insect peptide cardioacceleratory peptide 2b (CAP2b) or its intracellular messenger cyclic GMP. This shows that leucokinins act through Ca2+ and not through cyclic nucleotides and that the cyclic nucleotide pathways do not co-activate the intracellular Ca2+ pathway to exert their effects. Taken together, these results show that leucokinin acts through intracellular Ca2+, independently of cyclic AMP or cyclic GMP, to raise the chloride permeability of the epithelium. By contrast, either cyclic AMP or cyclic GMP (upon CAP2b stimulation) acts on the electrogenic cation-transporting apical V-ATPase, with only a negligible effect on anion conductance and without perturbing intracellular [Ca2+]. There is thus a clear functional separation between the control pathways acting on cation and anion transport in the tubules. Given the evidence from D. melanogaster and other species that chloride does not pass through the principal cells, we speculate that these two pathways may also be physically separated within cell subtypes of the tubules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Anatomy and Physiology of the Digestive Tract of Drosophila melanogaster
Miguel-Aliaga, I., Jasper, H., & Lemaitre, B. (2018) · Genetics · doi:10.1534/genetics.118.300224 · Cited by 491
The Digestive Tract of Drosophila melanogaster
Lemaitre, B., & Miguel-Aliaga, I. (2013) · Annual Review of Genetics · doi:10.1146/annurev-genet-111212-133343 · Cited by 469
Morphogenesis of epithelial tubes: Insights into tube formation, elongation, and elaboration
Andrew, D. J., & Ewald, A. J. (2010) · Developmental Biology · doi:10.1016/j.ydbio.2009.09.024 · Cited by 338
A novel diuretic hormone receptor in Drosophila: evidence for conservation of CGRP signaling
Johnson, E. C., Shafer, O. T., Trigg, J. S., Park, J., Schooley, D. A., Dow, J. A., & Taghert, P. H. (2005) · Journal of Experimental Biology · doi:10.1242/jeb.01529 · Cited by 254
Self-citationThe Multifunctional Drosophila melanogaster V-ATPase Is Encoded by a Multigene Family
Dow, J. A. T. (1999) · Journal of Bioenergetics and Biomembranes · doi:10.1023/a:1005400731289 · Cited by 55
Self-citation
Metadata
- Authors
- O’Donnell, M. J., Dow, J. A. T., Huesmann, G. R., Tublitz, N. J., & Maddrell, S. H. P.
- Venue
- Journal of Experimental Biology
- Publisher
- The Company of Biologists
- Published
- 1996-05-01
- Volume
- 199
- Issue
- 5
- Pages
- 1163-1175
- ISSN
- 0022-0949 (ISSN-L)
- 1477-9145
- OpenAlex
- W2156283333
- Cited by
- 251
- References
- 0
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separate Control Of Anion And Cation Transport In Malpighian Tubules Of Drosophila Melanogaster. https://app.cochat.ai/papers/10.1242/jeb.199.5.1163
- The paper
- O’Donnell, M. J., Dow, J. A. T., Huesmann, G. R., Tublitz, N. J., & Maddrell, S. H. P. (1996). Separate Control Of Anion And Cation Transport In Malpighian Tubules Of Drosophila Melanogaster. Journal of Experimental Biology. https://doi.org/10.1242/jeb.199.5.1163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.