Fibroblast responses to mechanical forces
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The repair and maintenance of connective tissues is performed predominately by a mesenchymal cell known as a fibroblast. The activity of this cell is regulated, in part, by changes in the mechanical environment in which it resides. The authors have addressed some of the questions related to the fibroblast and how it responds to mechanical stimulation. An in vitro model, the ‘culture force monitor’, and its derivative, the tensioning culture force monitor have been developed enabling quantitative investigations to be performed on fibroblasts in a collagen lattice. Results have shown that a fibroblast can generate a force of approximately 10−10 N, as a result of change in cell shape and attachment, while in a three-dimensional collagen lattice. Application of a physiologically similar mechanical load has shown that fibroblasts have the ability to maintain a tensional homeostasis of approximately 40–60×10−5 N per million cells, change cellular morphology in a predictable manner and biochemically modify their resident environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Functionalisation of magnetic nanoparticles for applications in biomedicine
Berry, C. C., & Curtis, A. S. G. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/203 · Cited by 1,588
Fibroblast biology in three-dimensional collagen matrices
Grinnell, F. (2003) · Trends in Cell Biology · doi:10.1016/s0962-8924(03)00057-6 · Cited by 819
A CONSTRAINED MIXTURE MODEL FOR GROWTH AND REMODELING OF SOFT TISSUES
HUMPHREY, J. D., & RAJAGOPAL, K. R. (2002) · Mathematical Models and Methods in Applied Sciences · doi:10.1142/s0218202502001714 · Cited by 758
Collagen self-assembly and the development of tendon mechanical properties
Silver, F. H., Freeman, J. W., & Seehra, G. P. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00135-0 · Cited by 645
Nucleus alignment and cell signaling in fibroblasts: response to a micro-grooved topography
Dalby, M. J., Riehle, M. O., Yarwood, S. J., Wilkinson, C. D. W., & Curtis, A. S. G. (2003) · Experimental Cell Research · doi:10.1016/s0014-4827(02)00053-8 · Cited by 408
Mechanobiology of force transduction in dermal tissue
Silver, F. H., Siperko, L. M., & Seehra, G. P. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00358.x · Cited by 380
Duan, J., Gherghe, C., Liu, D., Hamlett, E., Srikantha, L., Rodgers, L., Regan, J. N., Rojas, M., Willis, M., Leask, A., et al. (2012) · The EMBO Journal · doi:10.1038/emboj.2011.418 · Cited by 314
Mechanoregulation of gene expression in fibroblasts
Wang, J. H.-C., Thampatty, B. P., Lin, J.-S., & Im, H.-J. (2007) · Gene · doi:10.1016/j.gene.2007.01.014 · Cited by 265
Mechanotransduction of bone cellsin vitro: Mechanobiology of bone tissue
Mullender, M., El Haj, A. J., Yang, Y., van Duin, M. A., Burger, E. H., & Klein-Nulend, J. (2004) · Medical and Biological Engineering and Computing · doi:10.1007/bf02351006 · Cited by 238
Possible exploitation of magnetic nanoparticle–cell interaction for biomedical applications
Berry, C. C. (2005) · J. Mater. Chem. · doi:10.1039/b409715g · Cited by 209
Topographically induced direct cell mechanotransduction
Dalby, M. J. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.04.005 · Cited by 200
Fibroblast mechanics in 3D collagen matrices☆
RHEE, S., & GRINNELL, F. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.006 · Cited by 187
“Cells interacting with collagen matrices exhibit distinct patterns of signaling and migration [18–21] and remodel matrices both locally and globally [5,6,22–24] to achieve tensional homeostasis [25,26].”
BackgroundHutcheson, K. A., Atkins, B. Z., Hueman, M. T., Hopkins, M. B., Glower, D. D., & Taylor, D. A. (2000) · Cell Transplantation · doi:10.1177/096368970000900307 · Cited by 186
“(12) have proposed that mechanical activity of fibro blasts is regulated by the envi ronment into which they are placed, and that cellular morphology can adapt over t ime, our findings suggest that t ransplanted dermal Fb could not express the characterist ics that were needed to increase systolic performance.”
BackgroundExpression of integrin β1 by fibroblasts is required for tissue repair in vivo
Liu, S., Shi-wen, X., Blumbach, K., Eastwood, M., Denton, C. P., Eckes, B., Krieg, T., Abraham, D. J., & Leask, A. (2010) · Journal of Cell Science · doi:10.1242/jcs.070672 · Cited by 177
“Matrix remodeling and ECM contraction in floating gel matrices involves actin or myosin contraction (Daniels et al., 2003; Mirastschijski et al., 2004; Eastwood et al., 1998); thus blebbistatin blocked collagen gel contraction mediated by wild-type integrin 1 cells in floating collagen gel matrices (Fig.”
BackgroundSelf-citationCell–scaffold mechanical interplay within engineered tissue
Dado, D., & Levenberg, S. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2009.02.001 · Cited by 168
Effects of Repeated UVA Irradiation on Human Skin Fibroblasts Embedded in 3D Tense Collagen Matrix
Nakyai, W., Tissot, M., Humbert, P., Grandmottet, F., Viyoch, J., & Viennet, C. (2018) · Photochemistry and Photobiology · doi:10.1111/php.12895 · Cited by 15
Metadata
- Authors
- Eastwood, M., McGrouther, D. A., & Brown, R. A.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 1998-02-01
- Volume
- 212
- Issue
- 2
- Pages
- 85-92
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W1994845717
- Cited by
- 127
- References
- 1
- FWCI
- 0.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.