The DOI matches its Crossref record.
The compressive strength of articular cartilage
Abstract
Articular cartilage provides the smooth bearing surfaces in freely moving (synovial) joints. Its mechanical properties are important because structural failure of cartilage is closely associated with joint disorders, including osteoarthritis. Some mechanical properties of cartilage are well characterized, but little is known about its compressive strength. A technique for measuring cartilage compressive strength is evaluated, and an overview of experiments which relate strength to stiffness and tissue hydration is given. Specimens of bovine articular cartilage-on-bone, approximately 15 mm square, were loaded on a hydraulic materials testing machine using flat impermeable indentors. Linear-ramp loading/unloading cycles of 1 s duration, and of increasing severity, were applied until failure was evident on force-displacement graphs. Some specimens were tested following a 30 min period of creep loading. Inkstaining and histology were used to locate the site of initial damage to each specimen. Specimen failure occurred first in the cartilage surface layer at a nominal applied stress of 14–59 MPa (mean 35.7 MPa). Mechanical properties were little affected by specimen or indentor size, provided both remained within defined limits, and compressive strength could be measured to an accuracy of approximately ±5 per cent. Compressive stiffness was a significant predictor of strength, but only if it was measured at high levels of stress. Strength increased following creep-induced water loss, and initial mechanical damage could propagate under moderate cyclic loading. This technique for measuring cartilage compressive strength has potential for investigating the causes of cartilage failure in vivo
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Why are double network hydrogels so tough?
Gong, J. P. (2010) · Soft Matter · doi:10.1039/b924290b · Cited by 2,328
Mechanical properties of a novel PVA hydrogel in shear and unconfined compression
Stammen, J. A., Williams, S., Ku, D. N., & Guldberg, R. E. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00242-8 · Cited by 624
Willson, J. D., & Davis, I. S. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.025 · Cited by 386
How severe must repetitive loading be to kill chondrocytes in articular cartilage?
Clements, K. M., Bee, Z. C., Crossingham, G. V., Adams, M. A., & Sharif, M. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2000.0417 · Cited by 152
Self-citation
Metadata
- Authors
- Kerin, A. J., Wisnom, M. R., & Adams, M. A.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 1998-04-01
- Volume
- 212
- Issue
- 4
- Pages
- 273-280
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2103574785
- Cited by
- 200
- References
- 0
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The compressive strength of articular cartilage. https://app.cochat.ai/papers/10.1243/0954411981534051
- The paper
- Kerin, A. J., Wisnom, M. R., & Adams, M. A. (1998). The compressive strength of articular cartilage. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1243/0954411981534051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.