The compressive strength of articular cartilage
The DOI matches its Crossref record.
Abstract
Articular cartilage provides the smooth bearing surfaces in freely moving (synovial) joints. Its mechanical properties are important because structural failure of cartilage is closely associated with joint disorders, including osteoarthritis. Some mechanical properties of cartilage are well characterized, but little is known about its compressive strength. A technique for measuring cartilage compressive strength is evaluated, and an overview of experiments which relate strength to stiffness and tissue hydration is given. Specimens of bovine articular cartilage-on-bone, approximately 15 mm square, were loaded on a hydraulic materials testing machine using flat impermeable indentors. Linear-ramp loading/unloading cycles of 1 s duration, and of increasing severity, were applied until failure was evident on force-displacement graphs. Some specimens were tested following a 30 min period of creep loading. Inkstaining and histology were used to locate the site of initial damage to each specimen. Specimen failure occurred first in the cartilage surface layer at a nominal applied stress of 14–59 MPa (mean 35.7 MPa). Mechanical properties were little affected by specimen or indentor size, provided both remained within defined limits, and compressive strength could be measured to an accuracy of approximately ±5 per cent. Compressive stiffness was a significant predictor of strength, but only if it was measured at high levels of stress. Strength increased following creep-induced water loss, and initial mechanical damage could propagate under moderate cyclic loading. This technique for measuring cartilage compressive strength has potential for investigating the causes of cartilage failure in vivo
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Why are double network hydrogels so tough?
Gong, J. P. (2010) · Soft Matter · doi:10.1039/b924290b · Cited by 2,328
Mechanical properties of a novel PVA hydrogel in shear and unconfined compression
Stammen, J. A., Williams, S., Ku, D. N., & Guldberg, R. E. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00242-8 · Cited by 624
High strength graphene oxide/polyvinyl alcohol composite hydrogels
Zhang, L., Wang, Z., Xu, C., Li, Y., Gao, J., Wang, W., & Liu, Y. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm04043f · Cited by 439
Ionically Cross-Linked Triblock Copolymer Hydrogels with High Strength
Henderson, K. J., Zhou, T. C., Otim, K. J., & Shull, K. R. (2010) · Macromolecules · doi:10.1021/ma100963m · Cited by 409
Shin, H., Olsen, B. D., & Khademhosseini, A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.12.050 · Cited by 400
Willson, J. D., & Davis, I. S. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.025 · Cited by 386
Cartilage-like protein hydrogels engineered via entanglement
Fu, L., Li, L., Bian, Q., Xue, B., Jin, J., Li, J., Cao, Y., Jiang, Q., & Li, H. (2023) · Nature · doi:10.1038/s41586-023-06037-0 · Cited by 374
Bioinspired Nanocomposite Hydrogels with Highly Ordered Structures
Zhao, Z., Fang, R., Rong, Q., & Liu, M. (2017) · Advanced Materials · doi:10.1002/adma.201703045 · Cited by 368
Water‐Rich Biomimetic Composites with Abiotic Self‐Organizing Nanofiber Network
Xu, L., Zhao, X., Xu, C., & Kotov, N. A. (2018) · Advanced Materials · doi:10.1002/adma.201703343 · Cited by 259
Super-tough double-network hydrogels reinforced by covalently compositing with silica-nanoparticles
Wang, Q., Hou, R., Cheng, Y., & Fu, J. (2012) · Soft Matter · doi:10.1039/c2sm07233e · Cited by 219
Biomimetic hydrogels designed for cartilage tissue engineering
Ngadimin, K. D., Stokes, A., Gentile, P., & Ferreira, A. M. (2021) · Biomaterials Science · doi:10.1039/d0bm01852j · Cited by 202
Gleadall, A., Visscher, D., Yang, J., Thomas, D., & Segal, J. (2018) · Burns & Trauma · doi:10.1186/s41038-018-0121-4 · Cited by 172
“Scaffold strength is also critically important and may be in the range of 14 to 59 MPa for cartilage [41], 1 to 12 MPa for cancellous bone [42], and 50 to 190 MPa for cortical bone [42].”
BackgroundModern Strategies To Achieve Tissue-Mimetic, Mechanically Robust Hydrogels
Means, A. K., & Grunlan, M. A. (2019) · ACS Macro Letters · doi:10.1021/acsmacrolett.9b00276 · Cited by 159
How severe must repetitive loading be to kill chondrocytes in articular cartilage?
Clements, K. M., Bee, Z. C., Crossingham, G. V., Adams, M. A., & Sharif, M. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2000.0417 · Cited by 152
Self-citation
Metadata
- Authors
- Kerin, A. J., Wisnom, M. R., & Adams, M. A.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 1998-04-01
- Volume
- 212
- Issue
- 4
- Pages
- 273-280
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2103574785
- Cited by
- 200
- References
- 0
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.