Cited by 296Ultrasound and Hyperthermia ApplicationsManagement of metastatic bone diseasePain Management and Treatment

Pain palliation in patients with bone metastases using MR-guided focused ultrasound surgery: a multicenter study

Liberman, Boaz, Gianfelice, David, Inbar, Yael, Beck, Alexander, Rabin, Tatiana, Shabshin, Noga, Chander, Gupta, Hengst, Suzanne +5 more·2009·Annals of Surgical Oncology

Abstract

Background Noninvasive thermal ablation using magnetic resonance (MR)-guided focused ultrasound (MRgFUS) has been shown to be clinically effective in uterine fibroids, and is being evaluated for ablation of breast, liver, and brain lesions. Recently MRgFUS has been evaluated for palliation of pain caused by bone metastases. We present the clinical results of a multicenter study using MRgFUS for palliation of bone metastases pain.Methods A multicenter study to evaluate the safety and efficacy of MRgFUS palliative treatment of bone metastases was conducted in patients suffering from painful metastatic bone lesions for which other treatments were either ineffective or not feasible. Thirty-one patients with painful bone metastases underwent the MRgFUS procedure in three medical centers. Treatment safety was evaluated by assessing the device-related complications. Effectiveness of pain palliation was evaluated using the visual analog pain score (VAS), and measurable changes in the intake of opioid analgesics.Results Thirty-six procedures were performed on 31 patients. Mean follow-up time was 4 months. 25 patients underwent the planned treatment and were available for 3 months post-treatment follow-up. 72% of the patients (18/25) reported significant pain improvement. Average VAS score was reduced from 5.9 prior to treatment to 1.8 at 3 months post treatment. 67% of patients with recorded medication data reported a reduction in their opioid usage. No device-related severe adverse events were recorded.Conclusion The results suggest that MRgFUS has the ability to provide an accurate, effective, and safe noninvasive palliative treatment for patients with bone metastases.

Integrity signals

Registry

Crossref · 10.1245/s10434-008-0011-2

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Liberman, B., Gianfelice, D., Inbar, Y., Beck, A., Rabin, T., Shabshin, N., Chander, G., Hengst, S., Pfeffer, R., Chechick, A., Hanannel, A., Dogadkin, O., & Catane, R.
Affiliations
  • Sheba Medical Center (IL)
  • Toronto General Hospital (CA)
  • Stiftung Charité (DE)
  • InSightec (Israel) (IL)
Corresponding author
Liberman, Boaz
Venue
Annals of Surgical Oncology
Published
2009-01
Volume
16
Issue
1
Pages
140-146
ISSN
  • 1068-9265 (ISSN-L)
  • 1534-4681
OpenAlex
W1974160564
Cited by
296
References
41
Citations by year
2026: 4 · 2025: 5 · 2024: 7 · 2023: 6 · 2022: 17 · 2021: 16 · 2020: 12 · 2019: 21 · 2018: 19 · 2017: 17 · 2016: 27 · 2015: 28 · 2014: 34 · 2013: 33 · 2012: 16
FWCI
7.50
Type
journal article
Language
en
Open access
closed
Locations
  • Annals of Surgical Oncology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
  • Health Sciences › Medicine › Surgery › Management of metastatic bone disease
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
Keywords
MR-guided focused ultrasound, bone metastasis, pain palliation, thermal ablation, non-invasive treatment, visual analogue scale, treatment safety, device complications
MeSH terms
Adult, Aged, Aged, 80 and over, Bone Neoplasms, Female, Humans, Magnetic Resonance Imaging, Middle Aged, Palliative Care, Ultrasonic Therapy, Treatment Outcome, Pain Management

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review