High Performance Liquid Chromatographic Determination of Bound Sulfide and Sulfite and Thiosulfate at Their Low Levels in Human Serum by Pre-column Fluorescence Derivatization with Monobromobimane.
Open accessThe DOI matches its Crossref record.
Abstract
A sensitive and specific high performance liquid chromatographic method for the determination of sulfide, sulfite, and thiosulfate was established. Inorganic sulfur anions were converted into fluorescent derivatives with monobromobimane. The derivatives were separated on a coupled column chromatography with a reversed-phase octadecyl silica column connected with a weakly basic anion exchanger column by isocratic elution with acetic acid solution (pH 3)-acetonitrile (13:3, v/v) containing 25 mM NaClO4. The method was applied to the determination of bound sulfide and sulfite and thiosulfate in normal human serum. Thiosulfate could be determined directly by use of an ultrafiltered sample. For the determination of bound sulfide and sulfite, the pretreatment step with continuous flow gas dialysis was effective for the sample after releasing sulfide and sulfite by reduction with dithiothreitol. The limits of quantification by the present method were 0.05 microM for thiosulfate, 0.5 microM for bound sulfide, and 0.2 microM for bound sulfite.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogen sulphide and its therapeutic potential
Szabó, C. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2425 · Cited by 2,038
Biogenesis of reactive sulfur species for signaling by hydrogen sulfide oxidation pathways
Mishanina, T. V., Libiad, M., & Banerjee, R. (2015) · Nature Chemical Biology · doi:10.1038/nchembio.1834 · Cited by 615
Hydrogen sulfide chemical biology: pathophysiological roles and detection
Kolluru, G. K., Shen, X., Bir, S. C., & Kevil, C. G. (2013) · Nitric Oxide · doi:10.1016/j.niox.2013.07.002 · Cited by 480
Cao, X., Ding, L., Xie, Z.-Z., Yang, Y., Whiteman, M., Moore, P. K., & Bian, J.-S. (2019) · Antioxidants & Redox Signaling · doi:10.1089/ars.2017.7058 · Cited by 408
Chemical foundations of hydrogen sulfide biology
Li, Q., & Lancaster, J. R. (2013) · Nitric Oxide · doi:10.1016/j.niox.2013.07.001 · Cited by 334
Chemical aspects of hydrogen sulfide measurements in physiological samples
Nagy, P., Pálinkás, Z., Nagy, A., Budai, B., Tóth, I., & Vasas, A. (2014) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2013.05.037 · Cited by 283
Organization of the Human Mitochondrial Hydrogen Sulfide Oxidation Pathway
Libiad, M., Yadav, P. K., Vitvitsky, V., Martinov, M., & Banerjee, R. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.m114.602664 · Cited by 264
Hydrogen Sulfide in the Mammalian Cardiovascular System
Liu, Y.-H., Lu, M., Hu, L.-F., Wong, P. T.-H., Webb, G. D., & Bian, J.-S. (2012) · Antioxidants & Redox Signaling · doi:10.1089/ars.2011.4005 · Cited by 264
Tangerman, A. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.05.026 · Cited by 257
Is hydrogen sulfide a circulating “gasotransmitter” in vertebrate blood?
Olson, K. R. (2009) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/j.bbabio.2009.03.019 · Cited by 254
Wintner, E. A., Deckwerth, T. L., Langston, W., Bengtsson, A., Leviten, D., Hill, P., Insko, M. A., Dumpit, R., VandenEkart, E., Toombs, C. F., et al. (2010) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2010.00704.x · Cited by 229
“Monobromobimane has been used extensively to quantify thiols by forming fluorescent derivatives containing one bimane molecule per thiol group (Fahey et al., 1981; Newton et al., 1981; Togawa et al., 1992).”
MethodAnalytical measurement of discrete hydrogen sulfide pools in biological specimens
Shen, X., Peter, E. A., Bir, S., Wang, R., & Kevil, C. G. (2012) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2012.04.007 · Cited by 214
“Although DTT has been used by others [10,11,21,23] for this purpose, TCEP is water soluble, is nonvolatile, reduces disulfide bonds more rapidly, and has been shown to be very stable across a wide range of pH (2.”
BackgroundRemote light-controlled intracellular target recognition by photochromic fluorescent glycoprobes
Zhang, J., Fu, Y., Han, H.-H., Zang, Y., Li, J., He, X.-P., Feringa, B. L., & Tian, H. (2017) · Nature Communications · doi:10.1038/s41467-017-01137-8 · Cited by 185
Assay methods and biological roles of labile sulfur in animal tissues
Ubuka, T. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00623-2 · Cited by 165
Metadata
- Authors
- TOGAWA, T., OGAWA, M., NAWATA, M., OGASAWARA, Y., KAWANABE, K., & TANABE, S.
- Venue
- Chemical and Pharmaceutical Bulletin
- Publisher
- Pharmaceutical Society of Japan
- Published
- 1992
- Volume
- 40
- Issue
- 11
- Pages
- 3000-3004
- ISSN
- 0009-2363 (ISSN-L)
- 1347-5223
- OpenAlex
- W1994970191
- Cited by
- 89
- References
- 0
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.