The DOI matches its Crossref record.
Effect of ramp slope on determination of aerobic parameters from the ramp exercise test
Abstract
The effect of ramp slope on determination of aerobic parameters from the ramp exercise test. Med. Sci. Sports Exercise, Vol. 14, No. 5, pp. 339-343, 1982. We have previously demonstrated that the four parameters of aerobic function (maximal oxygen uptake (muVO2), VO2 at the anaerobic threshold (theta an), the time constant for VO2 kinetics (tau VO2), and work efficiency (eta)) may all be determined reliably from a single test in which the work rate increases continuously at a constant rate, i.e., ramp. That study, however, utilized a single ramp slope of 50 W X min-1, which may not be appropriate for subjects with very low or very high work tolerances. We therefore studied the effect of different ramp slopes on the determination of these parameters. Ramp slopes of 20, 30, 50, and 100 W X min-1 were generated on a cycle ergometer, and each was assigned randomly to 14 healthy subjects. Ventilatory and gas exchange variables were measured breath-by-breath utilizing on-line digital computation. Ramp slopes of 20, 30, and 50 W X min-1 yielded the same values for each aerobic parameter. The 100 W X min-1 ramp yielded muVO2 and eta an values that were the same as those found for the other ramp slopes, but tau VO2 and eta could not be discerned validly from this ramp slope. We conclude that valid assessment of the four parameters of aerobic function is possible with ramp slopes between 20 and 50 W X min-1; no further information on the parameters is to be gained by prolonging the tests with ramps slower than 20 W X min-1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
The maximally attainable V̇o2during exercise in humans: the peak vs. maximum issue
Day, J. R., Rossiter, H. B., Coats, E. M., Skasick, A., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2003 · Cited by 447
Self-citationMaltais, F., LeBlanc, P., Jobin, J., Bérubé, C., Bruneau, J., Carrier, L., Breton, M. J., Falardeau, G., & Belleau, R. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.2.9032194 · Cited by 418
Metadata
- Authors
- DAVIS, J. A., WHIPP, B. J., LAMARRA, N., HUNTSMAN, D. J., FRANK, M. H., & WASSERMAN, K.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1982-05
- Volume
- 14
- Issue
- 5
- Pages
- 339???343
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2042818779
- Cited by
- 223
- References
- 0
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of ramp slope on determination of aerobic parameters from the ramp exercise test. https://app.cochat.ai/papers/10.1249/00005768-198205000-00005
- The paper
- DAVIS, J. A., WHIPP, B. J., LAMARRA, N., HUNTSMAN, D. J., FRANK, M. H., & WASSERMAN, K. (1982). Effect of ramp slope on determination of aerobic parameters from the ramp exercise test. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-198205000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.