Effect of ramp slope on determination of aerobic parameters from the ramp exercise test
The DOI matches its Crossref record.
Abstract
The effect of ramp slope on determination of aerobic parameters from the ramp exercise test. Med. Sci. Sports Exercise, Vol. 14, No. 5, pp. 339-343, 1982. We have previously demonstrated that the four parameters of aerobic function (maximal oxygen uptake (muVO2), VO2 at the anaerobic threshold (theta an), the time constant for VO2 kinetics (tau VO2), and work efficiency (eta)) may all be determined reliably from a single test in which the work rate increases continuously at a constant rate, i.e., ramp. That study, however, utilized a single ramp slope of 50 W X min-1, which may not be appropriate for subjects with very low or very high work tolerances. We therefore studied the effect of different ramp slopes on the determination of these parameters. Ramp slopes of 20, 30, 50, and 100 W X min-1 were generated on a cycle ergometer, and each was assigned randomly to 14 healthy subjects. Ventilatory and gas exchange variables were measured breath-by-breath utilizing on-line digital computation. Ramp slopes of 20, 30, and 50 W X min-1 yielded the same values for each aerobic parameter. The 100 W X min-1 ramp yielded muVO2 and eta an values that were the same as those found for the other ramp slopes, but tau VO2 and eta could not be discerned validly from this ramp slope. We conclude that valid assessment of the four parameters of aerobic function is possible with ramp slopes between 20 and 50 W X min-1; no further information on the parameters is to be gained by prolonging the tests with ramps slower than 20 W X min-1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
The maximally attainable V̇o2during exercise in humans: the peak vs. maximum issue
Day, J. R., Rossiter, H. B., Coats, E. M., Skasick, A., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2003 · Cited by 447
Self-citationMaltais, F., LeBlanc, P., Jobin, J., Bérubé, C., Bruneau, J., Carrier, L., Breton, M. J., Falardeau, G., & Belleau, R. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.2.9032194 · Cited by 418
Use of exercise testing in the evaluation of interventional efficacy: an official ERS statement
Puente-Maestu, L., Palange, P., Casaburi, R., Laveneziana, P., Maltais, F., Neder, J. A., O'Donnell, D. E., Onorati, P., Porszasz, J., Rabinovich, R., et al. (2016) · European Respiratory Journal · doi:10.1183/13993003.00745-2015 · Cited by 412
Paridon, S. M., Alpert, B. S., Boas, S. R., Cabrera, M. E., Caldarera, L. L., Daniels, S. R., Kimball, T. R., Knilans, T. K., Nixon, P. A., Rhodes, J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.174375 · Cited by 325
The anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312
“Valid identification of GET relies on the fact that the incremental exercise stimulus (Whipp et al. 1981; Davis et al. 1982; Zhang et al. 1991) is sufficiently rapid that the onset of a metabolic acidosis is dissociated from that of compensatory hyperventilation.”
BackgroundBeltz, N. M., Gibson, A. L., Janot, J. M., Kravitz, L., Mermier, C. M., & Dalleck, L. C. (2016) · Journal of Sports Medicine · doi:10.1155/2016/3968393 · Cited by 306
Rossiter, H. B., Kowalchuk, J. M., & Whipp, B. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00932.2005 · Cited by 256
Self-citationExercise: Kinetic Considerations for Gas Exchange
Rossiter, H. B. (2010) · Comprehensive Physiology · doi:10.1002/cphy.c090010 · Cited by 231
Oxygen uptake as related to work rate increment during cycle ergometer exercise
Hansen, J. E., Casaburi, R., Cooper, D. M., & Wasserman, K. (1988) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00640653 · Cited by 213
Self-citationAerobic fitness in a population of independently living men and women aged 55-86 years
PATERSON, D. H., CUNNINGHAM, D. A., KOVAL, J. J., & ST. CROIX, C. M. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199912000-00018 · Cited by 210
V˙O2max, Protocol Duration, and the V˙O2 Plateau
YOON, B.-K., KRAVITZ, L., & ROBERGS, R. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b13e318054e304 · Cited by 181
Oxygen uptake kinetics and lactate concentration during exercise in humans.
Roston, W. L., Whipp, B. J., Davis, J. A., Cunningham, D. A., Effros, R. M., & Wasserman, K. (1987) · PubMed · doi:10.1164/arrd.1987.135.5.1080 · Cited by 180
Self-citationLevel ground and uphill cycling ability in professional road cycling
PADILLA, S., MUJIKA, I., CUESTA, G., & GOIRIENA, J. J. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199906000-00017 · Cited by 159
“maxima] and submaximal exercise intensities (5,35,37).”
Muscle oxygen saturation rates coincide with lactate-based exercise thresholds
Batterson, P. M., Kirby, B. S., Hasselmann, G., & Feldmann, A. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05238-9 · Cited by 45
GIGLIOTTI, F., ROMAGNOLI, I., & SCANO, G. (2003) · Respiratory Medicine · doi:10.1053/rmed.2003.1434 · Cited by 33
Metadata
- Authors
- DAVIS, J. A., WHIPP, B. J., LAMARRA, N., HUNTSMAN, D. J., FRANK, M. H., & WASSERMAN, K.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1982-05
- Volume
- 14
- Issue
- 5
- Pages
- 339???343
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2042818779
- Cited by
- 223
- References
- 0
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.