Physiological determinants of pulmonary gas exchange kinetics during exercise
The DOI matches its Crossref record.
Abstract
We consider how the optimal selection of the profile of imposed work rate, coupled with rigorous, statistically justified analysis of the pattern of the pulmonary gas exchange response, makes it possible to assemble a control model incorporating the proportional role of the muscle, circulation, and gas stores. Gains, time constants, and delays may be assigned to the components of the response and its linearity assessed. These techniques also allow the investigator to examine the features of poorly understood and even unexpected response patterns. Recent interest in the analysis of the non-steady state of exercise-in normal subjects and in patients with gas exchange defects-has led to an improved understanding of the sub-threshold dynamics. At work rates above the lactate threshold, the more complex kinetics are to date poorly described, and hence poorly understood, remaining a fertile area for the application of control-systems techniques to exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Muscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Mezzani, A., Agostoni, P., Cohen-Solal, A., Corrà, U., Jegier, A., Kouidi, E., Mazic, S., Meurin, P., Piepoli, M., Simon, A., et al. (2009) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832914c8 · Cited by 402
Taylor, N. A. S. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130022 · Cited by 331
Oxygen Uptake Kinetics during Exercise
Xu, F., & Rhodes, E. C. (1999) · Sports Medicine · doi:10.2165/00007256-199927050-00003 · Cited by 258
“O2 increases linearly with work rate with a gain of 9 to 11 ml O2/watt/min during moderate exercise.[4,6,13,16] In general, the whole response of V .”
InfluentialEffects of prior heavy exercise on phase II pulmonary oxygen uptake kinetics during heavy exercise
Burnley, M., Jones, A. M., Carter, H., & Doust, J. H. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1387 · Cited by 255
Interaction of factors determining oxygen uptake at the onset of exercise
Tschakovsky, M. E., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.4.1101 · Cited by 254
Faster adjustment of O2delivery does not affect V˙o 2 on-kinetics in isolated in situ canine muscle
Grassi, B., Gladden, L. B., Samaja, M., Stary, C. M., & Hogan, M. C. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.4.1394 · Cited by 253
Pringle, J. S. M., Doust, J. H., Carter, H., Tolfrey, K., Campbell, I. T., & Jones, A. M. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0799-1 · Cited by 216
“It has generally been considered that the gain of the _ V O2 primary component remains relatively constant at 10 ml min W across the continuum of sub-maximal exercise, with the emergence of the _ V O2 slow component at 90–150 s into exercise causing _ V O2 to rise above the expected requirement as exercise proceeds (W…”
InfluentialAutomated Metabolic Gas Analysis Systems: A Review
Macfarlane, D. J. (2001) · Sports Medicine · doi:10.2165/00007256-200131120-00002 · Cited by 198
Comparison of oxygen uptake kinetics during concentric and eccentric cycle exercise
Perrey, S., Betik, A., Candau, R., Rouillon, J. D., & Hughson, R. L. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.5.2135 · Cited by 176
“O2 deficit (O2Def) was calculated for exercise without evidence of a slow component as follows: O2Def 5 (A1 1 A2) zMRT (38).”
MethodExercise tolerance with helium-hyperoxia versus hyperoxia in hypoxaemic patients with COPD
Queiroga, F., Nunes, M., Meda, E., Chiappa, G., Machado, M. C., Nery, L. E., & Neder, J. A. (2013) · European Respiratory Journal · doi:10.1183/09031936.00087812 · Cited by 14
Metadata
- Authors
- WHIPP, B. J., & WARD, S. A.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1990-02
- Volume
- 22
- Issue
- 1
- Pages
- 62???71
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1976361070
- Cited by
- 211
- References
- 0
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.