Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure
The DOI matches its Crossref record.
Abstract
The Caltrac accelerometer is designed to assess energy expenditure during normal activity. The aims of the present study were (a) to determine the interinstrument and intersession reliability of the Caltrac and (b) to validate these instruments with measures of oxygen uptake (VO2) and determine whether Caltracs accurately reflect differences in energy expenditure due to sex, body weight, and speed. Caltracs were found to have very good interinstrument and intersession reliability and to accurately reflect differences in expenditure due to sex, weight, and speed. However, Caltracs consistently over-estimated energy expenditure by an average of 9-13%. The absolute percent error (percent error without consideration of the sign) of the Caltrac was greater, averaging 23%. The correlations between Caltrac and VO2 averaged 0.68-0.74. Thus, the Caltracs seem well suited for studies of activity level of groups, but may be less useful in estimating an individual's activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Objective Monitoring of Physical Activity Using Motion Sensors and Heart Rate
Freedson, P. S., & Miller, K. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082782 · Cited by 482
Measurement of energy expenditure
Levine, J. A. (2005) · Public Health Nutrition · doi:10.1079/phn2005800 · Cited by 401
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Study methodologies included the wearing of devices over the left and right hip [337, 370, 385, 387, 406, 413, 415, 417], over the hip and lower back [409], the wearing of devices side by side at the same location on the hip [301, 344, 411, 414, 416–418], devices worn at 3 intercostal space and just below the apex of…”
BackgroundMethodA comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Metadata
- Authors
- PAMBIANCO, G., WING, R. R., & ROBERTSON, R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1990-12
- Volume
- 22
- Issue
- 6
- Pages
- 858
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2016684191
- Cited by
- 93
- References
- 0
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure. https://app.cochat.ai/papers/10.1249/00005768-199012000-00020
- The paper
- PAMBIANCO, G., WING, R. R., & ROBERTSON, R. (1990). Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199012000-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.