Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure
The DOI matches its Crossref record.
Abstract
The Caltrac accelerometer is designed to assess energy expenditure during normal activity. The aims of the present study were (a) to determine the interinstrument and intersession reliability of the Caltrac and (b) to validate these instruments with measures of oxygen uptake (VO2) and determine whether Caltracs accurately reflect differences in energy expenditure due to sex, body weight, and speed. Caltracs were found to have very good interinstrument and intersession reliability and to accurately reflect differences in expenditure due to sex, weight, and speed. However, Caltracs consistently over-estimated energy expenditure by an average of 9-13%. The absolute percent error (percent error without consideration of the sign) of the Caltrac was greater, averaging 23%. The correlations between Caltrac and VO2 averaged 0.68-0.74. Thus, the Caltracs seem well suited for studies of activity level of groups, but may be less useful in estimating an individual's activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Objective Monitoring of Physical Activity Using Motion Sensors and Heart Rate
Freedson, P. S., & Miller, K. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082782 · Cited by 482
Measurement of energy expenditure
Levine, J. A. (2005) · Public Health Nutrition · doi:10.1079/phn2005800 · Cited by 401
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Study methodologies included the wearing of devices over the left and right hip [337, 370, 385, 387, 406, 413, 415, 417], over the hip and lower back [409], the wearing of devices side by side at the same location on the hip [301, 344, 411, 414, 416–418], devices worn at 3 intercostal space and just below the apex of…”
BackgroundMethodA comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Ainslie, P. N., Reilly, T., & Westerterp, K. R. (2003) · Sports Medicine · doi:10.2165/00007256-200333090-00004 · Cited by 309
The utility of the Digi-Walker step counter to assess daily physical activity patterns
WELK, G. J., DIFFERDING, J. A., THOMPSON, R. W., BLAIR, S. N., DZIURA, J., & HART, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00007 · Cited by 293
Exercise reduces daily fatigue in women with breast cancer receiving chemotherapy
SCHWARTZ, A. L., MORI, M., GAO, R., NAIL, L. M., & KING, M. E. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200105000-00006 · Cited by 290
Quantitating Physical Activity in COPD Using a Triaxial Accelerometer
Steele, B. G., Holt, L., Belza, B., Ferris, S., Lakshminaryan, S., & Buchner, D. M. (2000) · Chest · doi:10.1378/chest.117.5.1359 · Cited by 287
Compliance with cardiovascular disease prevention strategies: A review of the research
Burke, L. E., Dunbar-Jacob, J. M., & Hill, M. N. (1997) · Annals of Behavioral Medicine · doi:10.1007/bf02892289 · Cited by 286
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Uric acid reduces exercise-induced oxidative stress in healthy adults
WARING, W. S., CONVERY, A., MISHRA, V., SHENKIN, A., WEBB, D. J., & MAXWELL, S. R. J. (2003) · Clinical Science · doi:10.1042/cs20030149 · Cited by 256
Daily Fatigue Patterns and Effect of Exercise in Women with Breast Cancer
Schwartz, A. L. (2000) · Cancer Practice · doi:10.1046/j.1523-5394.2000.81003.x · Cited by 224
Physical activity assessment: A review of methods
Melanson, E. L., Freedson, P. S., & Blair, S. (1996) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408399609527732 · Cited by 223
Improving energy expenditure estimation by using a triaxial accelerometer
Chen, K. Y., & Sun, M. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.6.2112 · Cited by 211
“(21) also found that the accuracy of the Caltrac changed with gender, body mass, and walking speed.”
BackgroundMethodNonexercise activity thermogenesis – liberating the life‐force
Levine, J. A. (2007) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2007.01842.x · Cited by 205
Haeuber, E., Shaughnessy, M., Forrester, L. W., Coleman, K. L., & Macko, R. F. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.035 · Cited by 182
Improving Energy Expenditure Estimation for Physical Activity
ZHANG, K., PI-SUNYER, F. X., & BOOZER, C. N. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126585.40962.22 · Cited by 180
NICHOLS, J. F., MORGAN, C. G., SARKIN, J. A., SALLIS, J. F., & CALFAS, K. J. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199906000-00022 · Cited by 178
Lawson, O. J., Williamson, D. A., Champagne, C. M., DeLany, J. P., Brooks, E. R., Howat, P. M., Wozniak, P. J., Bray, G. A., & Ryan, D. H. (1995) · Obesity Research · doi:10.1002/j.1550-8528.1995.tb00131.x · Cited by 177
Non-Exercise Activity Thermogenesis (NEAT)
Levine, J. A. (2004) · Nutrition Reviews · doi:10.1111/j.1753-4887.2004.tb00094.x · Cited by 174
Overt Weight Stigma, Psychological Distress and Weight Loss Treatment Outcomes
Wott, C. B., & Carels, R. A. (2010) · Journal of Health Psychology · doi:10.1177/1359105309355339 · Cited by 174
Non-exercise activity thermogenesis (NEAT)
Levine, J. A. (2002) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1053/beem.2002.0227 · Cited by 160
The reliability, validity, and stability of a measure of physical activity in the elderly
Kochersberger, G., McConnell, E., Kuchibhatla, M. N., & Pieper, C. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90258-0 · Cited by 159
Soundy, A., Roskell, C., Stubbs, B., & Vancampfort, D. (2014) · Archives of Psychiatric Nursing · doi:10.1016/j.apnu.2013.12.002 · Cited by 131
Reducing Cardiovascular Risk Factors in Postmenopausal Women through a Lifestyle Change Intervention
Carels, R. A., Darby, L. A., Cacciapaglia, H. M., & Douglass, O. M. (2004) · Journal of Women's Health · doi:10.1089/154099904323087105 · Cited by 85
“Although Caltrac accelerometers 38,39 have been shown to overestimate the absolute energy cost (i.e., measured V O 2 ) of selected activities, these devices can be used to monitor changes in physical activity.”
Carels, R. A., Young, K. M., Coit, C., Clayton, A. M., Spencer, A., & Hobbs, M. (2008) · Eating Behaviors · doi:10.1016/j.eatbeh.2007.12.003 · Cited by 50
Metadata
- Authors
- PAMBIANCO, G., WING, R. R., & ROBERTSON, R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1990-12
- Volume
- 22
- Issue
- 6
- Pages
- 858
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2016684191
- Cited by
- 93
- References
- 0
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.