Oxygen consumption using the K2 telemetry system and a metabolic cart
The DOI matches its Crossref record.
Abstract
PEEL, C. and C. UTSEY. Oxygen consumption using the K2 telemetry system and a metabolic cart. Med. Sci. Sports Exerc., Vol. 25, No. 3, pp. 396–400, 1993. The purpose of this study was to compare measurements of oxygen consumption (VO2), ventilation (VE), and respiratory rate (RR) between a relatively new portable, telemetry system (K2) and a system that has been shown to be valid and reliable. Duplicate measurements were made at rest and during four levels of exercise in 10 subjects. Heart rate values were comparable for exercise at the same work level during gas collection using the two systems, indicating that the metabolic stresses were similar. Oxygen consumption measurements were significantly lower using the K2 system compared with a metabolic measurement cart (MMC). There was no significant difference in VE, but RR was lower for measurements made with the MMC. Compared with the MMC, the K2 system uses a slightly different formula to calculate VO2 because the content of carbon dioxide in expired air is not measured. To determine differences resulting from the method of calculating VO2, MMC measurements were applied to the formula used by the K2 system, and K.2 values were adjusted using the RER values obtained from the MMC. There were no differences between these calculated values and the values obtained directly from either the MMC or the K2 system. Consequently, we concluded that the lower VO2 values obtained with the K.2 system were attributed to the method of collecting and analyzing expired air, rather than to the method of calculating VO2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accuracy and reliability of a Cosmed K4b2 portable gas analysis system
Duffield, R., Dawson, B., Pinnington, H. C., & Wong, P. (2004) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(04)80039-2 · Cited by 246
Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240
“cumstances the metabolic measurements would have been made simultaneously (Bigard and Guezennec 1995; Lucia et al. 1993; Peel and Utsey 1993), however,”
BackgroundMethodAutomated Metabolic Gas Analysis Systems: A Review
Macfarlane, D. J. (2001) · Sports Medicine · doi:10.2165/00007256-200131120-00002 · Cited by 198
Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system
Bassett, D. R., Howley, E. T., Thompson, D. L., King, G. A., Strath, S. J., McLaughlin, J. E., & Parr, B. B. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.1.218 · Cited by 118
Pinnington, H. C., Wong, P., Tay, J., Green, D., & Dawson, B. (2001) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(01)80041-4 · Cited by 77
Metadata
- Authors
- PEEL, C., & UTSEY, C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1993-03
- Volume
- 25
- Issue
- 3
- Pages
- 396???400
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W4298134651
- Cited by
- 34
- References
- 0
- FWCI
- 12.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen consumption using the K2 telemetry system and a metabolic cart. https://app.cochat.ai/papers/10.1249/00005768-199303000-00016
- The paper
- PEEL, C., & UTSEY, C. (1993). Oxygen consumption using the K2 telemetry system and a metabolic cart. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199303000-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.