CoChat

A More Efficient Magnetic Resonance Imaging???Based Strategy for Measuring Quadriceps Muscle Volume

TRACY, BRIAN L., IVEY, FRED M., JEFFREY METTER, E., FLEG, JEROME L., SIEGEL, ELIOT L., HURLEY, BEN F. · 2003 · Medicine & Science in Sports & Exercise
Cited by 117

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To determine the accuracy of several magnetic resonance imaging (MRI)-based strategies for assessment of quadriceps muscle volume (MV) and changes in MV with training. METHODS: Images were acquired along the length of both thighs from young (26 +/- 3 yr, N= 23) and older (69 +/- 3 yr, N= 24) men and women before and after strength training. The quadriceps cross-sectional area (QCSA) of each section was measured before and after training. MV was directly assessed using all of the sections (each 9-mm thick with a 1-mm gap). Alternative estimates of MV were calculated using increasingly greater intervals between sections: every 1.1 cm (MV2), 3.1 cm (MV4), 5.1 cm (MV6), 7.1 cm (MV8), 9.1 cm (MV10), and a single QCSA (L1). The 95% limits of agreement (LOA, +/- 2 SD) between each alternative measure and the criterion measure MV were determined with Bland and Altman plots. Regression was used to predict MV from L1 and to obtain the standard error of the estimate (SEE). RESULTS: Before training, the 95% LOA with MV for the alternative measures ranged from 0.7% to 6.36% of MV, and the prediction of MV from L1 yielded a SEE x 2 of 14.1% of MV. For change in the alternative measures, the 95% LOA ranged from 10.3% to 26.3% of the total change in MV, and the prediction of deltaMV from deltaL1 yielded a SEE x 2 of 60% of the change in MV. CONCLUSION: Increasingly greater intervals between axial MRI sections result in substantially reduced agreement with a criterion measure of MV. The use of one axial section results in relatively higher error and thus should be used only when large effect sizes are expected.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000053722.53302.d6

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 117

Metadata

Authors
TRACY, B. L., IVEY, F. M., JEFFREY METTER, E., FLEG, J. L., SIEGEL, E. L., & HURLEY, B. F.
Venue
Medicine & Science in Sports & Exercise
Published
2003-03
Volume
35
Issue
3
Pages
425-433
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2080480440
Cited by
117
References
4
FWCI
1.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A More Efficient Magnetic Resonance Imaging???Based Strategy for Measuring Quadriceps Muscle Volume. https://app.cochat.ai/papers/10.1249/01.mss.0000053722.53302.d6
The paper
TRACY, B. L., IVEY, F. M., JEFFREY METTER, E., FLEG, J. L., SIEGEL, E. L., & HURLEY, B. F. (2003). A More Efficient Magnetic Resonance Imaging???Based Strategy for Measuring Quadriceps Muscle Volume. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000053722.53302.d6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.