The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running
Abstract
PURPOSE: To evaluate the reliability and validity of the CSA (model 7164) accelerometer (MTI) in a wide walking-running speed range in laboratory and field. METHOD: Twelve male subjects performed three treadmill walking/running sessions and one field trial with the same continuous protocol involving progressively increasing velocities at 5 min per interval from 3 to 6 km x h(-1) (walking) and 8 to 20 km x h(-1) (running). In the field trial, this protocol was terminated after 35 min (14 km.h(-1)), but the trial then extended with 5-km running at a freely chosen velocity. In both scenarios, two CSAs were mounted on each hip and the step frequency measured at each velocity. Oxygen uptake VO(2) x kg(-1) was measured on the last two treadmill sessions. Correlation analyses were performed for mean CSA output relationship with speed, VO(2) per kilogram, and step frequency. RESULTS: In all trials, CSA output rose linearly (R2 = 0.92, P < 0.001) with increasing speed until 9 km.h-1 but remained at approximately 10000 counts.min-1 during running, thus underestimating VO(2) per kilogram at speeds > 9 km x h(-1). Estimation errors increased with speed from 11% (P < 0.01) at 10 km x h(-1) to 48% (P < 0.001) at 16 km x h(-1), when assuming a linear relationship. Freely chosen velocities in the field trial ranged from 10.9 to 16.3 km.h-1. No difference in the CSA-speed relationship was observed between the two scenarios. Differences in CSA output between subjects could partially be attributed to differences in step frequency (R = -0.34 (P = 0.02) for walking and R = -0.63 (P < 0.001) for running). CONCLUSION: CSA output increases linearly with speed in the walking range but not in running, presumably due to relatively constant vertical acceleration in running. Between-subject reliability was related to step frequency because CSA data are filtered most at higher movement frequencies. Epidemiological CSA data should thus be interpreted with these limitations in mind.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
The sources of external work in level walking and running.
Cavagna, G. A., Thys, H., & Zamboni, A. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011613 · Cited by 804
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
A critical discussion of intraclass correlation coefficients
Müller, R., & Büttner, P. (1994) · Statistics in Medicine · doi:10.1002/sim.4780132310 · Cited by 714
Mechanical work and efficiency in level walking and running
Cavagna, G. A., & Kaneko, M. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011866 · Cited by 664
Running in the real world: adjusting leg stiffness for different surfaces
Ferris, D. P., Louie, M., & Farley, C. T. (1998) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1998.0388 · Cited by 594
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
External, Internal and Total Work in Human Locomotion
Willems, P. A., Cavagna, G. A., & Heglund, N. C. (1995) · Journal of Experimental Biology · doi:10.1242/jeb.198.2.379 · Cited by 405
Cited by
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Andersen, L. B., Harro, M., Sardinha, L. B., Froberg, K., Ekelund, U., Brage, S., & Anderssen, S. A. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69075-2 · Cited by 1,473
Self-citationValidation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Physical Activity in U.S. Adults
Tucker, J. M., Welk, G. J., & Beyler, N. K. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2010.12.016 · Cited by 977
Accelerometer Data Reduction: A Comparison of Four Reduction Algorithms on Select Outcome Variables
MÂSSE, L. C., FUEMMELER, B. F., ANDERSON, C. B., MATTHEWS, C. E., TROST, S. G., CATELLIER, D. J., & TREUTH, M. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185674.09066.8a · Cited by 676
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Self-citationCalibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Assessment of physical activity in youth
Corder, K., Ekelund, U., Steele, R. M., Wareham, N. J., & Brage, S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2008 · Cited by 581
Self-citationAssessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
Brage, S., Wedderkopp, N., Ekelund, U., Franks, P. W., Wareham, N. J., Andersen, L. B., & Froberg, K. (2004) · Diabetes Care · doi:10.2337/diacare.27.9.2141 · Cited by 536
Self-citationEkelund, U., Sepp, H., Brage, S., Becker, W., Jakes, R., Hennings, M., & Wareham, N. J. (2006) · Public Health Nutrition · doi:10.1079/phn2005840 · Cited by 499
Self-citationBrage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Self-citationQuantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Estimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Physical Activity in US Youth: Effect of Race/Ethnicity, Age, Gender, and Weight Status
BELCHER, B. R., BERRIGAN, D., DODD, K. W., EMKEN, B. A., CHOU, C.-P., & SPRUIJT-METZ, D. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e1fba9 · Cited by 355
Accelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Self-citationA novel method for using accelerometer data to predict energy expenditure
Crouter, S. E., Clowers, K. G., & Bassett, D. R. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00818.2005 · Cited by 345
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Sabia, S., van Hees, V. T., Shipley, M. J., Trenell, M. I., Hagger-Johnson, G., Elbaz, A., Kivimaki, M., & Singh-Manoux, A. (2014) · American Journal of Epidemiology · doi:10.1093/aje/kwt330 · Cited by 304
Brage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Self-citationActivity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297
Calibration of an accelerometer during free-living activities in children
Mattocks, C., Leary, S., Ness, A., Deere, K., Saunders, J., Tilling, K., Kirkby, J., Blair, S. N., & Riddoch, C. (2007) · International Journal of Pediatric Obesity · doi:10.1080/17477160701408809 · Cited by 271
Physical activity, cardiorespiratory fitness, and the metabolic syndrome in youth
Steele, R. M., Brage, S., Corder, K., Wareham, N. J., & Ekelund, U. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00072.2008 · Cited by 259
Self-citationInternational Physical Activity Questionnaire: Reliability and validity in a Spanish population
Roman‐Viñas, B., Serra‐Majem, L., Hagströmer, M., Ribas‐Barba, L., Sjöström, M., & Segura‐Cardona, R. (2010) · European Journal of Sport Science · doi:10.1080/17461390903426667 · Cited by 258
Parent-child relationship of directly measured physical activity
Fuemmeler, B. F., Anderson, C. B., & Mâsse, L. C. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-17 · Cited by 257
Objective physical activity measurement in the osteoarthritis initiative: Are guidelines being met?
Dunlop, D. D., Song, J., Semanik, P. A., Chang, R. W., Sharma, L., Bathon, J. M., Eaton, C. B., Hochberg, M. C., Jackson, R. D., Kwoh, C. K., et al. (2011) · Arthritis & Rheumatism · doi:10.1002/art.30562 · Cited by 240
Taylor, A. M., Phillips, K., Patel, K. V., Turk, D. C., Dworkin, R. H., Beaton, D., Clauw, D. J., Gignac, M. A. M., Markman, J. D., Williams, D. A., et al. (2016) · Pain · doi:10.1097/j.pain.0000000000000577 · Cited by 208
Adam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202
“validity [10–28].”
Comparison of PAEE from Combined and Separate Heart Rate and Movement Models in Children
Corder, K., Brage, S., Wareham, N. J., & Ekelund, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000176466.78408.cc · Cited by 170
Self-citationGenerating ActiGraph counts from raw acceleration recorded by an alternative monitor.
BRØND, J. C., ANDERSEN, L. B., & ARVIDSSON, D. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001344 · Cited by 166
Self-citationIntegration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126
Self-citationModerate to vigorous physical activity and weight outcomes: does every minute count?
Fan, J. X., Brown, B. B., Hanson, H., Kowaleski-Jones, L., Smith, K. R., & Zick, C. D. (2013) · American Journal of Health Promotion · doi:10.4278/ajhp.120606-qual-286 · Cited by 84
Predicting walking METs and energy expenditure from speed or accelerometry
BROOKS, A. G., GUNN, S. M., WITHERS, R. T., GORE, C. J., & PLUMMER, J. L. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000170074.19649.0e · Cited by 73
Slootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69
Andersen, E., Burton, N. W., & Anderssen, S. A. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-47 · Cited by 47
Metadata
- Authors
- BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2003-08
- Volume
- 35
- Issue
- 8
- Pages
- 1447-1454
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2089180972
- Cited by
- 347
- References
- 29
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.