The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running
Abstract
PURPOSE: To evaluate the reliability and validity of the CSA (model 7164) accelerometer (MTI) in a wide walking-running speed range in laboratory and field. METHOD: Twelve male subjects performed three treadmill walking/running sessions and one field trial with the same continuous protocol involving progressively increasing velocities at 5 min per interval from 3 to 6 km x h(-1) (walking) and 8 to 20 km x h(-1) (running). In the field trial, this protocol was terminated after 35 min (14 km.h(-1)), but the trial then extended with 5-km running at a freely chosen velocity. In both scenarios, two CSAs were mounted on each hip and the step frequency measured at each velocity. Oxygen uptake VO(2) x kg(-1) was measured on the last two treadmill sessions. Correlation analyses were performed for mean CSA output relationship with speed, VO(2) per kilogram, and step frequency. RESULTS: In all trials, CSA output rose linearly (R2 = 0.92, P < 0.001) with increasing speed until 9 km.h-1 but remained at approximately 10000 counts.min-1 during running, thus underestimating VO(2) per kilogram at speeds > 9 km x h(-1). Estimation errors increased with speed from 11% (P < 0.01) at 10 km x h(-1) to 48% (P < 0.001) at 16 km x h(-1), when assuming a linear relationship. Freely chosen velocities in the field trial ranged from 10.9 to 16.3 km.h-1. No difference in the CSA-speed relationship was observed between the two scenarios. Differences in CSA output between subjects could partially be attributed to differences in step frequency (R = -0.34 (P = 0.02) for walking and R = -0.63 (P < 0.001) for running). CONCLUSION: CSA output increases linearly with speed in the walking range but not in running, presumably due to relatively constant vertical acceleration in running. Between-subject reliability was related to step frequency because CSA data are filtered most at higher movement frequencies. Epidemiological CSA data should thus be interpreted with these limitations in mind.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
The sources of external work in level walking and running.
Cavagna, G. A., Thys, H., & Zamboni, A. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011613 · Cited by 804
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
A critical discussion of intraclass correlation coefficients
Müller, R., & Büttner, P. (1994) · Statistics in Medicine · doi:10.1002/sim.4780132310 · Cited by 714
Mechanical work and efficiency in level walking and running
Cavagna, G. A., & Kaneko, M. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011866 · Cited by 664
Running in the real world: adjusting leg stiffness for different surfaces
Ferris, D. P., Louie, M., & Farley, C. T. (1998) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1998.0388 · Cited by 594
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
External, Internal and Total Work in Human Locomotion
Willems, P. A., Cavagna, G. A., & Heglund, N. C. (1995) · Journal of Experimental Biology · doi:10.1242/jeb.198.2.379 · Cited by 405
Biomechanical factors affecting running economy
KYR??L??INEN, H., BELLI, A., & KOMI, P. V. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200108000-00014 · Cited by 320
Biomechanics and Running Economy
Anderson, T. (1996) · Sports Medicine · doi:10.2165/00007256-199622020-00003 · Cited by 309
Evaluation of heart rate as a method for assessing moderate intensity physical activity
STRATH, S. J., SWARTZ, A. M., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00005 · Cited by 301
Cavagna, G. A., & Margaria, R. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.1.271 · Cited by 285
Cavagna, G. A., Franzetti, P., Heglund, N. C., & Willems, P. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017069 · Cited by 254
Rehrig, P. W., Park, S.-E., Trolier-McKinstry, S., Messing, G. L., Jones, B., & Shrout, T. R. (1999) · Journal of Applied Physics · doi:10.1063/1.370943 · Cited by 231
Nichols, J. F., Morgan, C. G., Chabot, L. E., Sallis, J. F., & Calfas, K. J. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.10608878 · Cited by 203
Effects of wind assistance and resistance on the forward motion of a runner
Davies, C. T. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.48.4.702 · Cited by 169
Field evaluation of the Computer Science and Applications, Inc. physical activity monitor
Sirard, J. R., Melanson, E. L., Li, L., & Freedson, P. S. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200003000-00022 · Cited by 164
Metabolic cost of generating horizontal forces during human running
Chang, Y.-H., & Kram, R. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.5.1657 · Cited by 164
Methods to assess physical activity with special reference to motion sensors and accelerometers
Meijer, G. A. L., Westerterp, K. R., Verhoeven, F. M. H., Koper, H. B. M., & ten Hoor, F. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.133202 · Cited by 162
Technical reliability of the CSA activity monitor: The EarlyBird Study
Metcalf, B. S., Curnow, J. S. H., EVANS, C. J., Voss, L. D., & Wilkin, T. J. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200209000-00022 · Cited by 144
Energy cost and running mechanics during a treadmill run to voluntary exhaustion in humans
Candau, R. B., Belli, A., Millet, G. Y., Dalleau, G., Barbier, B., & Rouillon, J. D. (1998) · European Journal of Applied Physiology · doi:10.1007/s004210050363 · Cited by 132
Assessment of energy expenditure by recording heart rate and body acceleration
Meijer, G. A. L., Westerterp, K. R., Koper, H. B. M., & ten Hoor, F. (1989) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198906000-00020 · Cited by 129
A model equation for the prediction of mechanical internal work of terrestrial locomotion
Minetti, A. E. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00038-4 · Cited by 125
The two power limits conditioning step frequency in human running.
Cavagna, G., Willems, P. A., Franzetti, P., & Detrembleur, C. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018586 · Cited by 108
Brage, S., Brage, N., Wedderkopp, N., & Froberg, K. (2003) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0702_4 · Cited by 95
Self-citationA combined heart rate and movement sensor: proof of concept and preliminary testing study
Rennie, K., Rowsell, T., Jebb, S., Holburn, D., & Wareham, N. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600973 · Cited by 83
Walking and running energy expenditure estimated by Caltrac and indirect calorimetry
Haymes, E. M., & Byrnes, W. C. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199312000-00008 · Cited by 80
Cited by
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Andersen, L. B., Harro, M., Sardinha, L. B., Froberg, K., Ekelund, U., Brage, S., & Anderssen, S. A. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69075-2 · Cited by 1,473
Self-citationValidation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Metadata
- Authors
- BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2003-08
- Volume
- 35
- Issue
- 8
- Pages
- 1447-1454
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2089180972
- Cited by
- 347
- References
- 29
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.